shop-logo
Schneider Electric
Search in this Shop
Search Icon
Press
forward-slash-icon
to jump to the search box
Schneider Electric LADR4 Time Delay Auxiliary Contact Block - Tesys D
Image
Image
Product Description

Schneider Electric LADR4 Time Delay Auxiliary Contact Block - Tesys D


TeSys Deca time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, Off-delay setting range 10-180s, connection by screw clamp terminals. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).

Main

  • Range: TeSys, TeSys Deca
  • Product Name: TeSys Deca
  • Product or Component Type: Time Delay Auxiliary Contact Block
  • Range Compatibility:
    • TeSys Deca CAD
    • TeSys Deca LC1D
    • TeSys F LC1F
    • TeSys F CR1F
  • Mounting Location: Front
  • Pole Contact Composition: 1 NO + 1 NC
  • Contacts Operation: Time Delay
  • Timer Type: Off Delay
  • Time Delay Range: 10...180 s
  • [Ue] Rated Operational Voltage: 690 V AC 25...400 Hz
  • [Ie] Rated Operational Current:
    • 6 A at 120 V AC-15
    • 1.04 A at 690 V AC-15
    • 0.55 A at 125 V DC-13
    • 0.1 A at 600 V DC-13
  • [Ui] Rated Insulation Voltage:
    • 690 V conforming to IEC 60947-5-1
    • 600 V conforming to UL 60947-5-1
    • 600 V conforming to CSA C22.2 No 60947-5-1
  • [Ith] Conventional Free Air Thermal Current: 10 A (at 60 °C)
  • Standards: GB/T 14048.5
  • Product Certifications:
    • IECEE CB Scheme
    • UL
    • CSA
    • CCC
    • EAC
    • UKCA

Complementary:

  • Irms Rated Making Capacity:
      • 140 A at <= 690 V AC conforming to IEC 60947-5-1
      • 250 A at <= 690 V DC conforming to IEC 60947-5-1
  • Permissible Short-time Rating:
    • 100 A 60 °C 1 s
    • 120 A 60 °C 500 ms
    • 140 A 60 °C 100 ms
  • Protection Type: GG fuse 10 A
  • Mechanical Durability: 5 Mcycles
  • Minimum Switching Current: 5 mA
  • Minimum Switching Voltage: 17 V
  • Non-overlap Time:
    • 1.5 ms on de-energisation no overlap between NC and NO contact
    • 1.5 ms on energisation no overlap between NC and NO contact
  • Insulation Resistance: > 10 MOhm
  • Connections - Terminals:
    • Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
    • Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
    • Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
    • Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
    • Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
    • Screw clamp terminals 2 cable(s) 1…2.5 mm²rigid
    • Screw clamp terminals
  • Tightening Torque:
    • 1.7 N.m - with screwdriver flat Ø 6 mm
    • 1.7 N.m - with screwdriver Philips No 2
    • 1.7 N.m - with screwdriver pozidriv No 2
  • Dimensions:
    • Height: 48 mm
    • Width: 44 mm
    • Depth: 61 mm
  • Colour: Dark grey

Environment

  • Environmental Characteristic: Normal environment
  • IP Degree of Protection: IP20 conforming to IEC 60529
  • Protective Treatment: TH conforming to IEC 60068
  • Ambient Air Temperature:
    • Storage: -60…80 °C
    • Operation: -40…70 °C
  • Operating Altitude: 3000 m
US $ 78.05
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Time Delay Contact Block from SCHNEIDER ELECTRIC
Source & compare similar products
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top