Schneider Electric Variable Speed Drive - 2.2kW - 3hp - 480V - 3ph - Emc - IP21 ATV212HU22N4
Schneider Electric Variable Speed Drive - 2.2kW - 3hp - 480V - 3ph - Emc - IP21 ATV212HU22N4
Image
Image
Technical Data Sheets
Product Description

SCHNEIDER ELECTRIC Variable Speed Drive - 2.2kW - 3hp - 480V - 3ph - Emc - IP21 ATV212HU22N4

This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 2.2kW / 3hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It can also be mounted directly on a 35 mm wide DIN rail, thanks to the kit VW3A31852, to order separately. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.

US $ 673.22
Image
Restocking
Contact us at enquiry@eezee.com.sg or +65 6797 9688 for more details. Item will take longer than normal to be delivered.
Quantity:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Power Supply
23 Items
power-supply-img
Standards
CSA C22.2 No 60950-1 UL 508 EN/IEC 62368-1, IEC 62368-1 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 CSA C22.2 No 62368-1 UL 508 CSA C22.2 No 107.1 EN/IEC 62368-1, IEC 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 IEC 60335-1 EN/IEC 62368-1, UL 508 CSA C22.2 No 60950-1 EN/IEC 62368-1, CSA C22.2 No 60950-1 UL 508
Connections - Terminals
Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection, Screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) for output Screw connection: 0.75...2.5 mm², (AWG 18...AWG 14) for input, For ground connection: screw type terminals, connection capacity: 1 x 4 mm² AWG 12, Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for output ground connection, For output connection: screw type terminals, connection capacity: 2 x 0.5...2 x 10 mm² AWG 20...AWG 8 For input connection: screw type terminals, connection capacity: 4 x 0.5...4 x 10 mm² AWG 20...AWG 8 For diagnostic relay: removable screw terminal block, connection capacity: 1 x 2.5 mm² AWG 14
Product Certifications
CCSAus EAC UL RCM KC, CE CUL listed CUL recognized RCM CB Scheme EAC KC, CE CULus EAC RCM CB Scheme KC, CCSAus EAC KC RCM UL, EAC RCM
Inrush Current
45 A at 100...240 V AC, 35 A at 115 V 70 A at 230 V, 40.0 A at 115 V 80.0 A at 230 V, 50 A at 100...240 V AC, 30 A
Power Supply Output Current
2.2 A, 2.5 A, 6.25 A, 3.13 A, 5 A
-
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power Supply from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power Supply
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top