Operating Temperature
-20…60 °C
Standards and Certifications
CSA C22.2 No 14 EN 60947-4-1 IACS E10 UL 508 IEC 60947-4-1
Width
91 mm
Depth
122.5 mm
[Ui] Rated Insulation Voltage
690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508
[Uimp] Rated Impulse Withstand Voltage
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1
Ip Degree Of Protection
IP20
Height
61 mm
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys T
This spec is not available in the specification table.
Device Short Name
LTMR
This spec is not available in the specification table.
Device Application
Equipment monitoring and control
This spec is not available in the specification table.
Connection Pitch
5.08 mm
This spec is not available in the specification table.
Compatibility Code
LTMR
This spec is not available in the specification table.
Measurement Current
5…100 A
This spec is not available in the specification table.
Connections - Terminals
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…80 °C
This spec is not available in the specification table.
Operating Altitude
<= 2000 m without derating
This spec is not available in the specification table.
Tightening Torque
Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
This spec is not available in the specification table.
Measurement Accuracy
5...15 % earth fault current internal measurement 1 % voltage (100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 5 % active and reactive power 0,02 current
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
This spec is not available in the specification table.
Associated Fuse Rating
4 A gG for output 0.5 A gG for control circuit
This spec is not available in the specification table.
Maximum Operating Rate
1800 cyc/h
This spec is not available in the specification table.
Product Certifications
C-Tick ABS UL DNV NOM RINA RMRoS BV LROS (Lloyds register of shipping) KERI EAC CCC CSA ATEX GL
This spec is not available in the specification table.
Protective Treatment
12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068
This spec is not available in the specification table.
Mechanical Robustness
Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
This spec is not available in the specification table.
Fire Resistance
650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94
This spec is not available in the specification table.
Logic Input Number
6
This spec is not available in the specification table.
Input Current
3.1 mA at 100 V 7.5 mA at 240 V
This spec is not available in the specification table.
Current State 0 Guaranteed
Logic input: 0...40 V and <= 15 mA for 25 ms
This spec is not available in the specification table.
Current State 1 Guaranteed
Logic input: 79...264 V and >= 2 mA for 25 ms
This spec is not available in the specification table.
Maximum Output Switching Frequency
2 Hz
This spec is not available in the specification table.
Contacts Type And Composition
1 NO + 1 NC fault signal 3 NO
This spec is not available in the specification table.
Metering Type
Phase current I1, I2, I3 RMS Temperature Earth-fault current Average current Iavg Imbalance current
This spec is not available in the specification table.
[Us] Rated Supply Voltage
100...240 V AC 50/60 Hz
This spec is not available in the specification table.
Supply Voltage Limits
93.5…264 V AC
This spec is not available in the specification table.
Protection Type
Reverse polarity protection Overload Phase unbalance Overload (long time) Thermal protection Power factor variation Thermal overload protection Locked rotor Earth-leakage protection Load fluctuation Phase failure
This spec is not available in the specification table.
Current Consumption
8...62.8 mA
This spec is not available in the specification table.
Load Current
5 A at 250 V AC for logic output 5 A at 30 V DC for logic output
This spec is not available in the specification table.
Web Services
Web server
This spec is not available in the specification table.
Communication Port Protocol
Modbus TCP/EtherNet/IP
This spec is not available in the specification table.
Bus Type
Ethernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs
This spec is not available in the specification table.
Short-Circuit Withstand
100 kA conforming to EN/IEC 60947-4-1
This spec is not available in the specification table.
Network And Machine Diagnosis Type
Waiting time after overload tripping Motor control command recording Trip context information Phase fault and earth fault trip counters Starting current and time Trip history information Fault recording Event recording Remaining operating time before overload tripping Running hours counter/operating time
This spec is not available in the specification table.
Permissible Power
480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
This spec is not available in the specification table.
Product Description
US $ 1,848.94
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Starter from SCHNEIDER ELECTRIC
Source & compare similar products
More from Motor Starter
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top