Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Schneider Electric CAD326R7 Control Relay, Tesys Deca, 3NO+2NC, 0 to 690V, 440VAC 50/60Hz Standard Coil, Lugs-ring Terminals
Schneider Electric CAD326R7 Control Relay, Tesys Deca, 3NO+2NC, 0 to 690V, 440VAC 50/60Hz Standard Coil, Lugs-ring Terminals
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Control Relays dimensions or variations
Please select at least one specification below.
Utilisation Category
AC-14 AC-15 DC-13
Standards
EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1
[Ui] Rated Insulation Voltage
600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1
Mounting Support
Plate Rail
Ip Degree Of Protection
IP2X front face conforming to VDE 0106
Ambient Air Temperature For Operation
-40…60 °C 60…70 °C with derating
Mechanical Durability
30 Mcycles
Ambient Air Temperature For Storage
-60…80 °C
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C)
Minimum Switching Current
5 mA
Insulation Resistance
> 10 MOhm
Product Certifications
CB CCC UL CSA EAC CE UKCA
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947
This spec is not available in the specification table.
Connections - Terminals
Lugs-ring terminals (external diameter: 8 mm)
This spec is not available in the specification table.
Range
TeSys TeSys Deca
This spec is not available in the specification table.
Product Name
TeSys CAD
This spec is not available in the specification table.
Operating Altitude
0...3000 m
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
<= 690 V AC 25...400 Hz
This spec is not available in the specification table.
Contactor Application
Control circuit
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
440 V AC 50/60 Hz
This spec is not available in the specification table.
Pole Contact Composition
3 NO + 2 NC
This spec is not available in the specification table.
Irms Rated Making Capacity
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1
This spec is not available in the specification table.
[Icw] Rated Short-Time Withstand Current
100 A - 1 s 120 A - 500 ms 140 A - 100 ms
This spec is not available in the specification table.
Associated Fuse Rating
10 A gG conforming to IEC 60947-5-1
This spec is not available in the specification table.
Control Circuit Type
AC at 50/60 Hz
This spec is not available in the specification table.
Control Circuit Voltage Limits
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
This spec is not available in the specification table.
Inrush power in VA
70 VA 50 Hz (at 20 °C)
This spec is not available in the specification table.
Hold-In Power Consumption In Va
8 VA 50 Hz (at 20 °C)
This spec is not available in the specification table.
Operating Time
12...22 ms coil energisation and NO closing 4...12 ms coil de-energisation and NO opening 4...19 ms coil energisation and NC opening 6...17 ms coil de-energisation and NC closing
This spec is not available in the specification table.
Maximum Operating Rate
180 cyc/mn
This spec is not available in the specification table.
Minimum Switching Voltage
17 V
This spec is not available in the specification table.
Non-Overlap Time
1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact
This spec is not available in the specification table.
Protective Treatment
TH conforming to IEC 60068
This spec is not available in the specification table.
Mechanical Robustness
Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
This spec is not available in the specification table.
Product Description
US $ 69.37
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Control Relays
37 Items
control-relays-img
Utilisation Category
DC-13 AC-15 AC-14, AC-14 AC-15 DC-13, AC-14 DC-13 AC-15, AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1, AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1
Standards
EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1, IEC 61984, IEC 60255-6, IEC 60255-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947 690 V conforming to VDE 0110 group C 690 V conforming to BS 5424 690 V conforming to UL 508 690 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947 750 V conforming to VDE 0110 group C 690 V conforming to BS 5424 600 V conforming to CSA C22.2 No 14, 400 V, 250 V conforming to IEC 60664-1, 250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1
Ip Degree Of Protection
IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529, IP20 conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 IP30 (housing) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Ambient Air Temperature For Operation
-40…60 °C 60…70 °C with derating, -20…60 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz AC/DC, -25…85 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz
Mechanical Durability
20 Mcycles, 30 Mcycles, 10 Mcycles, 10000000 cycles, 30000000 cycles
Ambient Air Temperature For Storage
-50…80 °C, -60…80 °C, -50…70 °C, -40…85 °C, -40…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Control Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Control Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top