Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Schneider Electric A9V44340 Earth Leakage add-on Block - Vigi iC60
Schneider Electric A9V44340 Earth Leakage add-on Block - Vigi iC60
Image
Image
Technical Data Sheets
Product Description

SCHNEIDER ELECTRIC Vigi iC60 - Earth Leakage add-on Block - 3P - 40A - 300mA - Ac Type A9V44340

This Acti9 Vigi iC60 is a modular add-on residual current devices. It is a 3P, rated current is 40A, operating voltage is 400VAC to 415VAC according to IEC 61009-1. The earth leakage protection class is AC type with a sensitivity of 300mA and a voltage independent technology. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. It can be combined with iC60 or Acti9 Reflex iC60, to provide protection of persons and protection of installations. A VisiTrip window is here to indicate a fault tripping by a red mechanical indicator on the front face. The Ue rated operational voltage is 400VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The pollution degree is 3. It can be mounted on DIN rail. The width in 9mm pitches is 7. The dimensions are (W) 117mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature -5°C to +60°C. The storage temperature is -40°C to +85°C.

US $ 174.81
Image
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Miniature Circuit Breakers - MCBs
714 Items
miniature-circuit-breakers-mcbs-img
Range
Resi 9, Square D, TeSys, Multi 9, PowerPact
Poles Description
1P, 3P+N, 2P, 3P, 4P
[In] Rated Current
1.6 A, 3.5 A, 3.2 kA, 24 A, 25 A
Breaking Capacity
15 kA, 30 kA, 20 kA, 3 kA, 15 kA, 30 kA, 20 kA, 15 kA
Standards
EN 60898-1 EN 60947-2 IEC 60947-2 IEC 60898-1, EN 60947-2 IEC 60947-2 IEC 60898-1 EN 60898-1, EN/IEC 60898-1 EN/IEC 60947-2, EN/IEC 60947-2 EN/IEC 60898-1, IEC 60947-2 EN 60898-1 EN 60947-2 IEC 60898-1
Magnetic Tripping Limit
8.5 x In +/- 20 % AC 12 x In +/- 20 % DC, 5...10 x In, 8 x In +/- 20 %, 4 x In +/- 20 %, 12 x In +/- 20 %
Connection - Terminals
Tunnel type terminals (downstream) 0.5…25 mm² rigid Tunnel type terminals (upstream) 0.5…25 mm² rigid Tunnel type terminals (downstream) 0.5…16 mm² flexible Tunnel type terminals (upstream) 0.5…16 mm² flexible Tunnel type terminals (downstream) 0.5…16 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…16 mm² flexible with ferrule, Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible, Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminal (top or bottom) 1…35 mm² rigid Tunnel type terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible Tunnel type terminals (downstream) 0.5…25 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…25 mm² flexible with ferrule
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Miniature Circuit Breakers - MCBs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Miniature Circuit Breakers - MCBs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top