Technical Data Sheets
Specifications
infotip-icon
View other Residual current devices - RCDs dimensions or variations
Please select at least one specification below.
Mounting Type
DIN Rail
This spec is not available in the specification table.
Rated Current
63A
This spec is not available in the specification table.
Weight
0.21kg
This spec is not available in the specification table.
Operating Temperature Range
-5°C to 60°C
This spec is not available in the specification table.
Breaking Capacity
1500A
This spec is not available in the specification table.
Poles
2P
This spec is not available in the specification table.
Standards and Certifications
EN/IEC 61008-1
This spec is not available in the specification table.
Dimensions
(W) 36mm x (H) 91mm x (D) 73.5mm
This spec is not available in the specification table.
Product Description

SCHNEIDER ELECTRIC Residual Current Circuit Breaker (rccb), Acti9 Iid, 2P, 63A, Ac Type, 500mA A9R16263

  • This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 2P circuit breaker with 63A In rated current, a sensitivity of 500mA with a AC type protection class. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The mechanical endurance is going up to 20000 cycles and electrical endurance going up to 15000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.
US $ 69.74
Image
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Residual current devices - RCDs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Residual current devices - RCDs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top