SCHNEIDER ELECTRIC Acti 9 K60N 1P - 32 a - B Curve 6000 A

Main

  • Device application Distribution
  • Range Acti9
  • Product name Acti9 K60
  • Product or component type Miniature circuit-breaker
  • Device short name K60N
  • Poles description 1P
  • Number of protected
  • poles
  • [In] rated current 40 A
  • Network type AC
  • Trip unit technology Thermal-magnetic
  • Curve code B
  • Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/
  • IEC 60898-1
  • Utilisation category Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN/IEC 60898-1
  • Standards EN/IEC 60898-1
  • Product certifications OVE
  • VDE

Complementary

  • Network frequency 50/60 Hz
  • Magnetic tripping limit 3...5 x In
  • [Ics] rated service breaking capacity 6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz
  • Limitation class 3 conforming to EN/IEC 60898-1
  • [Ui] rated insulation voltage 440 V AC 50/60 Hz conforming to EN/IEC 60898-1
  • [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60898-1
  • Contact position indicator No
  • Control type Toggle
  • Local signalling Without
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar and distribution block compatibility Downside: biconnect
  • 9 mm pitches 2
  • Height 81 mm
  • Width 18 mm
  • Depth 70 mm
  • Net weight 0.12 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Tunnel type terminals (downstream) 0.5…35 mm² rigid
  • Tunnel type terminals (upstream) 0.5…35 mm² rigid
  • Tunnel type terminals (downstream) 0.5…25 mm² flexible
  • Tunnel type terminals (upstream) 0.5…25 mm² flexible
  • Wire stripping length 14 mm for top or bottom connection
  • Tightening torque 3.5 N.m top or bottom
  • Earth-leakage protection Without

Environment

  • IP degree of protection IP20 conforming to IEC 60529
  • Pollution degree 2 conforming to IEC 60898-1
  • 2 conforming to EN 60898-1
  • Overvoltage category II
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % at 55 °C
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -25…70 °C
  • Ambient air temperature for storage -25…85 °C

Packing Units

  • Unit Type of Package 1 PCE
  • Number of Units in Package 1 1
  • Package 1 Height 1.8 cm
  • Package 1 Width 7.5 cm
  • Package 1 Length 8.5 cm
  • Package 1 Weight 120 g
  • Unit Type of Package 2 BB1
  • Number of Units in Package 2 12
  • Package 2 Height 8.2 cm
  • Package 2 Width 8.8 cm
  • Package 2 Length 22 cm
  • Package 2 Weight 1.485 kg
  • Unit Type of Package 3 S03
  • Number of Units in Package 3 144
  • Package 3 Height 30 cm
  • Package 3 Width 30 cm
  • Package 3 Length 40 cm
  • Package 3 Weight 18.371 kg
US $ 50.40
Image
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Img
MOQ of 12 EA
Img
Bundle of 12 EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Miniature Circuit Breakers - MCBs
714 Items
miniature-circuit-breakers-mcbs-img
Range
Resi 9, Acti 9, Easy 9, Multi 9, TeSys
Poles Description
3P+N, 1P+N, 1P, 3P, 2P
[In] Rated Current
3.2 kA, 500 mA, 25 A, 24 A, 3 A
Breaking Capacity
15 kA, 30 kA, 3000 A, 50 kA, 20 kA
Standards
EN 60898-1 EN 60947-2 IEC 60947-2 IEC 60898-1, EN 60947-2 IEC 60947-2 IEC 60898-1 EN 60898-1, EN 60947-2 IEC 60898-1 EN 60898-1 IEC 60947-2, EN 60947-2 EN 60898-1 IEC 60898-1 IEC 60947-2, EN 60898-1 IEC 60898-1 EN 60947-2 IEC 60947-2
Magnetic Tripping Limit
4 x In +/- 20 %, 3...5 x In, 5...10 x In, 10...14 x In, 8 x In +/- 20 %
Connection - Terminals
Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible Tunnel type terminals (downstream) 0.5…25 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…25 mm² flexible with ferrule, Tunnel type terminals (downstream) 0.5…35 mm² rigid, Tunnel type terminals (downstream) 0.5…25 mm² rigid Tunnel type terminals (upstream) 0.5…25 mm² rigid Tunnel type terminals (downstream) 0.5…16 mm² flexible Tunnel type terminals (upstream) 0.5…16 mm² flexible Tunnel type terminals (downstream) 0.5…16 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…16 mm² flexible with ferrule, Tunnel type terminal (top or bottom) 1…35 mm² rigid Tunnel type terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Miniature Circuit Breakers - MCBs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Miniature Circuit Breakers - MCBs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top