Specifications
infotip-icon
View other Isolator Switches dimensions or variations
Please select at least one specification below.
Range
ComPact
Poles Description
3P
Standards
IEC 60947-1 IEC 60947-3
IP Degree of Protection
IP40 conforming to IEC 60529
[Ue] Rated Operational Voltage
125 V DC 690 V AC 50/60 Hz
[Ie] Rated Operational Current
AC-22A: 125 A AC 50/60 Hz 220/240 V AC-22A: 125 A AC 50/60 Hz 380/415 V AC-22A: 125 A AC 50/60 Hz 440/480 V 2 poles in series AC-22A: 125 A AC 50/60 Hz 500 V 2 poles in series AC-22A: 125 A AC 50/60 Hz 660/690 V AC-23A: 125 A AC 50/60 Hz 220/240 V AC-23A: 125 A AC 50/60 Hz 380/415 V AC-23A: 125 A AC 50/60 Hz 440/480 V AC-23A: 125 A AC 50/60 Hz 500 V AC-23A: 80 A AC 50/60 Hz 660/690 V DC-22A: 125 A DC 50/60 Hz 125 V 2 poles in series DC-23A: 125 A DC 50/60 Hz 125 V 2 poles in series
Width
135 mm
This spec is not available in the specification table.
Control Type
Rotary handle
This spec is not available in the specification table.
Product Name
ComPacT INS
This spec is not available in the specification table.
Depth
62.5 mm
This spec is not available in the specification table.
Network Type
AC DC
This spec is not available in the specification table.
Height
100 mm
This spec is not available in the specification table.
Connection Pitch
30 mm
This spec is not available in the specification table.
Mounting Mode
Fixed
This spec is not available in the specification table.
Network Frequency
50/60 Hz
This spec is not available in the specification table.
Suitability for Isolation
Yes
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
750 V AC 50/60 Hz
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
8 kV
This spec is not available in the specification table.
Contact Position Indicator
Yes
This spec is not available in the specification table.
Mounting Support
DIN rail Plate
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Ambient Air Temperature for Operation
-25…70 °C
This spec is not available in the specification table.
Mechanical Durability
15000 cycles
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-50…85 °C
This spec is not available in the specification table.
Electrical Durability
AC-22A: 1500 cycles 220/240 V AC 50/60 Hz AC-22A: 1500 cycles 380/415 V AC 50/60 Hz 2 poles in series AC-22A: 1500 cycles 440 V AC 50/60 Hz AC-22A: 1500 cycles 500 V AC 50/60 Hz AC-23A: 1500 cycles 220/240 V AC 50/60 Hz AC-23A: 1500 cycles 380/415 V AC 50/60 Hz AC-23A: 1500 cycles 440 V AC 50/60 Hz AC-23A: 1500 cycles 500 V AC 50/60 Hz DC-22A: 1500 cycles 250 V DC 50/60 Hz 2 poles in series DC-23A: 1500 cycles 250 V DC 50/60 Hz 2 poles in series AC-22A: 1500 cycles 690 V AC 50/60 Hz AC-23A: 1500 cycles 690 V AC 50/60 Hz 2 poles in series
This spec is not available in the specification table.
[Ith] conventional free air thermal current
125 A at 60 °C
This spec is not available in the specification table.
[Icw] rated short-time withstand current
0.01 kA during 30 s conforming to IEC 60947-3 1.23 kA during 20 s conforming to IEC 60947-3 3.175 kA during 3 s conforming to IEC 60947-3 5.5 kA during 1 s conforming to IEC 60947-3
This spec is not available in the specification table.
Product certifications
CCC KEMA-KEUR
This spec is not available in the specification table.
Rated duty
Uninterrupted
This spec is not available in the specification table.
IK Degree of Protection
IK07 conforming to EN 50102
This spec is not available in the specification table.
Upside connection
Front
This spec is not available in the specification table.
downside connection
Front
This spec is not available in the specification table.
[Icm] rated short-circuit making capacity
154 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz 20 kA switch-disconnector alone 690 V AC at 50/60 Hz
This spec is not available in the specification table.
Maximum power
AC-23: 55 kW at 440 V AC 50/60 Hz AC-23: 37 kW at 220/240 V AC 50/60 Hz AC-23: 55 kW at 380/415 V AC 50/60 Hz AC-23: 75 kW at 500/525 V AC 50/60 Hz AC-23: 75 kW at 660/690 V AC 50/60 Hz
This spec is not available in the specification table.
Intermittent duty class
Class 120 - 60 %
This spec is not available in the specification table.
handle colour
Black
This spec is not available in the specification table.
Visible break
No
This spec is not available in the specification table.
enclosure dimensions for Ithe
260 mm x 160 mm x 55 mm
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Isolator Switches from SCHNEIDER ELECTRIC
Source & compare similar products
More from Isolator Switches
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top