Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Murr Elektronik 7000-08041-6301000 M8 Female 0° A-cod. With Cable Pur 3x0.25 Bk UL/CSA+drag Ch. 10m
Murr Elektronik 7000-08041-6301000 M8 Female 0° A-cod. With Cable Pur 3x0.25 Bk UL/CSA+drag Ch. 10m
Image
Image
Image
Image
Image
Image
Product Description

Murr 7000-08041-6301000 M8 Female 0° A-cod. With Cable Pur 3x0.25 Bk UL/CSA+drag Ch. 10m

Cable Details

  • Cable length: 10 m

Side 1 (Connector)

  • Tightening torque: 0.4 Nm
  • Mounting method: Inserted, screwed
  • Coating contact: Gold plated
  • Family construction form: M8
  • Thread: M8 x 1
  • Suitable for corrugated tube (internal Ø): 6.5 mm
  • Cable outlet: Straight
  • Coding: A
  • Material contact: Copper alloy
  • Material: PUR (Polyurethane)
  • No. of poles: 3
  • Width across flats: SW9
  • Degree of protection (EN IEC 60529): IP65, IP66K, IP67

Side 2 (Free Cable End)

  • Stripping length (jacket): 20 mm
  • Family construction form: Free cable end

Electrical Data | Supply

  • Operating voltage AC max.: 50 V
  • Operating voltage DC max.: 60 V
  • Current operating per contact max.: 4 A

Diagnostics

  • Status indication LED: No

Installation | Connection

  • Stripping length (jacket): 20 mm
  • Mounting set: M8 x 1

Device Protection | Electrical

  • Additional condition protection degree: Inserted, screwed
  • Pollution Degree: 3
  • Rated surge voltage: 1.5 kV
  • Material group (IEC 60664-1): I

Mechanical Data | Material Data

  • Coating locking: Nickeled
  • Coating of fitting: Nickel plated
  • Material gasket: FKM (Fluorocarbon rubber)
  • Locking material: Zinc die-casting
  • Material screw connection: Zinc die-casting

Mechanical Data | Mounting Data

  • Mounting method: Inserted, screwed, shaking protection

Environmental Characteristics | Climatic

  • Operating temperature min.: -30 °C
  • Operating temperature max.: 85 °C
  • Additional condition temperature range: Depending on cable quality

Important Installation Notes

  • Strain relief: Protect connectors from mechanical loads with cable ties.
  • Bending radius: Observe the permissible bending radii to maintain IP protection class. Excessive bending could compromise protection.

Conformity

  • Product standard: DIN EN 61076-2-104 (M8)

Cable Specifications

  • Cable identification: 630
  • Cable Type: 3
  • Jacket Color: Black
  • Type of Certificate: cURus

Cable Structure

  • Amount of stranding: 1
  • Stranding: 3 wires twisted
  • Wire arrangement: Brown, black, blue

Mechanical Data | Cable

  • Cable weight: 26.4 g/m
  • Material jacket: PUR
  • Shore hardness jacket: 90 ± 5 Shore A
  • Freedom from ingredients (jacket): Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
  • Outer diameter (jacket): 4.1 mm
  • Tolerance outer diameter (sheath): ± 5 %
  • Material wire insulation: PP (Polypropylene)
  • Amount wires: 3
  • Outer diameter insulation: 1.25 mm
  • Outer diameter tolerance core insulation: ± 5 %
  • Shore hardness wire insulation: 70 ± 5 Shore D
  • Ingredient freeness wire insulation: Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
  • Amount strands (wire): 32
  • Diameter of single wires: 0.1 mm
  • Conductor cross-section (wire): 0.25 mm²
  • Material conductor wire: Stranded copper wire, bare
  • Conductor type (wire): Strand class 6

Electrical Data | Cable

  • Nominal voltage AC max.: 300 V
  • Current load capacity (standard): To DIN VDE 0298-4
  • Current load capacity min. wire: 4.5 A
  • Electrical resistance line constant wire: 79 Ω/km @ 20 °C
  • AC withstand voltage (wire - wire): 2.5 kV @ 60 s
  • Power frequency withstand voltage (wire - jacket): 2.5 kV @ 60 s

Temperature Range | Cable

  • Min. operating temperature (static): -40 °C
  • Max. operating temperature (fixed): 80 °C / 90 °C @ 10,000 h operation
  • Operating temperature min. (dynamic): -25 °C
  • Operating temperature max. (dynamic): 80 °C / 90 °C @ 10,000 h operation

Resistances | Cable

  • UV resistance: DIN EN ISO 4892-2 A
  • Flame resistance:
    • UL 1581 § 1090
    • UL 1581 § 1100 FT2
    • IEC 60332-2-2
  • Chemical resistance: Good, application-related testing
  • Gasoline resistance: Good, application-related testing
  • Oil resistance: Good, application-related testing | DIN EN 60811-404

Installation | Cable

  • Bending radius (fixed): 5 x Outer diameter
  • Bending radius (dynamic): 10 x Outer diameter
  • No. of bending cycles (C-track): 10 million @ 25 °C
  • Traversing distance (C-track): 10 m @ 25 °C | Horizontal
  • Travel speed (C-track): 3 m/s @ 25 °C
  • No. of torsion cycles: 2 million
  • Torsion stress: ± 180 °/m
  • Torsion speed: 35 cycles/min
US $ 37.07
Image
Lead time of 10 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Ethernet Cable from Murr Elektronik
Source & compare similar products
More from Ethernet Cable
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top