Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Lumberg Automation 934878007 0980 ESL 300-121 LioN-P, Profinet I/O Device, 16DIO (8x M12), M12 L-coded Power Supply, Metal, 60 Mm
Lumberg Automation 934878007 0980 ESL 300-121 LioN-P, Profinet I/O Device, 16DIO (8x M12), M12 L-coded Power Supply, Metal, 60 Mm
Image
Image
Product Description

Lumberg Automation 934878007 0980 ESL 300-121 LioN-P, Profinet I/O Device, 16DIO (8x M12), M12 L-coded Power Supply, Metal, 60 Mm

  • Product Family: I/O Systems: Active - Standalone
  • Product Sub Family: LioN-P
  • Item Description: 0980 ESL 300-121
  • Device Type: I/O Module
  • Protocol: PROFINET
  • I/O Function: 16DIO
  • Bus Connection: M12, 4-poles, D-coded
  • Power Connection (System Supply): M12 Power, 5-poles, L-coded
  • I/O Connection: M12, 5-poles, A-coded
  • I/O Type: Digital In-/Output (Universal)

General Data:

  • Housing Material: Metal, Zinc Die-cast
  • Housing Plating: Nickel, matt
  • Housing Color: Grey Metallic
  • Protection Degree / IP Rating: IP65, IP67, IP69K
  • Potted: Yes
  • Dimensions (W x H x D): 60 mm x 31 mm x 200 mm
  • Weight: 500 g
  • Ambient Temperature (Operation): -20 °C to 70 °C
  • Ambient Temperature (Storage/Transport): -25 °C to 85 °C
  • Permissible Humidity (Operation): 5 % ... 95 % (For UL applications max. 80 %)
  • Permissible Humidity (Storage/Transport): 5 % ... 95 % (For UL applications max. 80 %)
  • Air Pressure (Operation): 80 kPa … 106 kPa (up to 2000 m above sea level)
  • Air Pressure (Storage/Transport): 80 kPa … 106 kPa (up to 2000 m above sea level)
  • Flammability Class: UL 94 (IEC 61010)
  • Protection Class: III, IEC 61140, EN 61140, VDE 0140-1
  • Pollution Degree: 3 acc. to EN 60664-1, VDE 0110-1
  • Vibration Resistance: 15 g / 5 -500 Hz
  • Shock Resistance: 50 g / 11ms
  • Mean Time To Failure (MTTF): 429 years, acc. to Telcordia SR-332 (2011) 20°C
  • Contact Base Material: M12, D-coded, CuSn, Gold-plated | M12 Power, L-coded, CuNi, Gold-plated
  • Contact Bearer Material: PA
  • O-Ring Material: FKM
  • Mounting: 2 hole screw mounting. Use standard M4 x 25 / 30 screws with toothed lock washer (as per DIN 125) and self-locking nuts.
  • Fastening Torque (Fixing Screw): M4: 1 Nm
  • Fastening Torque (Ground Connection (FE)): M4: 1 Nm
  • Fastening Torque (Bus Connection): M12: 0.5 Nm
  • Fastening Torque (Power Connection): M12: 0.5 Nm
  • Fastening Torque (I/O Connection): M12: 0.5 Nm
  • Included in Delivery: Attachable Labels: 15x, Sealing Caps: 5x M12

PROFINET:

  • Protocol: PROFINET
  • Connection: M12 LAN, 4-poles, D-coded
  • Number of Connections: 2
  • Netload Class: III
  • Specification: V2.3X
  • Conformance Class: C
  • Performance Class: RT (switch supports IRT)
  • Transmission Rate: Fast Ethernet (10/100 Mbit/s), Full Duplex
  • Transmission Method: 100 BASE-TX, with auto negotiation and auto crossing
  • Cycle Time / Update Rate: min. 1 ms
  • Addressing: DCP
  • Fast Startup (FSU): Supported, ≤ 1000 ms
  • Media Redundancy Protocol (MRP): Supported, MRP client
  • Shared Device: Not Supported
  • Topology Detection: LLDP, SNMP V1
  • Easy Device Replacement: Supported, based on LLDP
  • Supported Network Protocols (Other): ARP, HTTP, Ping, SNMP V1, TCP/IP

Power Supply:

  • Connection Module Supply Voltage: M12 Power, 5-poles, L-coded
  • Number of Connections: 2
  • Current Carrying Capacity of Connector: max. 16 A
  • Module Supply Voltage (Nominal): 24 V DC (SELV/PELV)
  • Module Supply Voltage (Range): 18 V DC to 30 V DC
  • Current Consumption (typ.): 120 mA (at 24 V DC)
  • Reverse Polarity Protection: Yes
  • Status Indicator (System Supply): LED green
  • Diagnostic Indicator: LED red
  • Connection Sensor Supply Voltage: M12 Power, 5-poles, L-coded
  • Current Carrying Capacity of Connector: max. 16 A
  • Sensor Supply Voltage (Nominal): 24 V DC (SELV/PELV)
  • Sensor Supply Voltage (Range): 18 V DC to 30 V DC
  • Reverse Polarity Protection: Yes
  • Status Indicator (Sensor Supply): LED green
  • Diagnostic Indicator: LED red
  • Connection Actuator Supply Voltage: via Module Supply Connection
  • Current Carrying Capacity of Connector: max. 16 A
  • Actuator Supply Voltage (Nominal): 24 V DC (SELV/PELV)
  • Actuator Supply Voltage (Range): 18 V DC to 30 V DC
  • Reverse Polarity Protection: Yes
  • Status Indicator (Actuator Supply): LED green
  • Diagnostic Indicator: LED red

Digital Input Channels:

  • Number of Digital Input Channels: max. 16, universal
  • Connection: M12, 5-poles, A-coded
  • Number of Ports: 8x, X1 to X8
  • Channel Type: Type 3 acc. to IEC 61131-2
  • Sensor Current Supply: max. 500 mA per port
  • Input Wiring: 2-, 3-, 4-wire
  • Nominal Voltage: 24 V DC via US (module power supply)
  • Nominal Current: typ. 5 mA
  • Sensor Type: PNP
  • Input Voltage Range "0" signal: -3 V DC …+5 V DC
  • Input Voltage Range "1" signal: 11 V DC … 30 V DC
  • Input Filter Time: 3 ms, fixed
  • Protective Circuit: Electronically: Overload protection, short-circuit protection
  • Status Indicator (Inputs): LED white or yellow per channel
  • Diagnostic Indicator: LED red per port

Digital Output Channels:

  • Number of Digital Output Channels: max. 16, universal
  • Connection: M12, 5-poles, A-coded
  • Number of Ports: 8x, X1 to X8
  • Output Current per Channel: max. 2 A
  • Channel Type: p-switching
  • Output Wiring: 2-wire
  • Nominal Voltage: 24 V DC via UL (actuator power supply)
  • Output Current per Module: max. 9 A
  • Galvanically Isolated: No
  • Protective Circuit: Electronically: Overload protection, short-circuit protection
  • Overload Behavior: Auto off and on switching / Manual restart
  • Status Indicator (Outputs): LED white or yellow per channel
  • Diagnostic Indicator: LED red per channel

Electrical Isolation:

  • US (System Supply Voltage) / FE: 500 V DC
  • UL / FE: 500 V DC
  • Bus connection / FE: 2000 V DC

EMC Conformance:

  • EMC Directive: 2014/30/EU
  • EN 61000-4-2 Electrostatic Discharge (ESD): Criterion B; 4 kV contact discharge, 8 kV air discharge
  • EN 61000-4-3 Electromagnetic Field: Criterion A; Field intensity: 10 V/m
  • EN 61000-4-4 Fast Transients (Burst): Criterion B, 2 kV
  • EN 61000-4-5 Surge Voltage: Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical); For I/O ports with cables ≤ 30m
  • EN 61000-4-6 Conducted immunity: Criterion A; Test voltage 10 V
  • EN 55022 Radio Interference Properties: Class A

Safety & Environmental Compliance:

  • CE: Yes
  • RoHS Compliant: Yes
  • China RoHS-Compliant: Yes

Approvals:

  • UL: cULus Listed, UL 61010-1
  • UL-File: E230848
  • CSA: Yes, via UL
  • PNO: Yes

Notes:

  • Protection Degree / IP Rating Note: ** only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
  • System Power Supply Connection Note: *do not connect / disconnect under voltage!
US $ 900.51
UnitsDiscountUnit Price
1-US $ 900.51
Image
Lead time of 126 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
This item is sold by
Image
SG-1400063614
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Safety IO Modules from Lumberg Automation
Source & compare similar products
More from Safety IO Modules
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top