Shopping List
Shopping List
USD - US$
Image
/
/
/
/
Abb MS132-4.0 Starter Motor Manual 4A
Abb MS132-4.0 Starter Motor Manual 4A
Brand:
ABB
Model:
MS132-4.0
Image
Image
Product Description

Abb MS132-4.0 Starter Motor Manual 4A

  • Extended Product Type:MS132-4.0
  • Product ID:1SAM350000R1008
  • EAN:4013614400087
  • Catalog Description:MS132-4.0 Manual Motor Starter 2.5 ... 4.0 A
  • Long Description:The MS132-4.0 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 4.00 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 100 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and terminal spacers are available as accessory.
  • Unit of Measurement : PCS

Technical

  • Rated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 100 kA
  • (250 V DC) 3 Poles in Series 10 kA
  • (400 V AC) 100 kA
  • (440 V AC) 30 kA
  • (500 V AC) 20 kA
  • (690 V AC) 3 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V AC) 100 kA
  • (400 V AC) 100 kA
  • (440 V AC) 30 kA
  • (500 V AC) 20 kA
  • (690 V AC) 3 kA
  • Rated Instantaneous Short-Circuit Current Setting (Ii):50 A
  • Setting Range:2.5 ... 4.0 A
  • Rated Operational Power AC-3 (Pe):(400 V) Three Phase 1.5 kW
  • Rated Operational Power AC-3e (Pe):(400 V) Three Phase 1.5 kW
  • Rated Operational Voltage:Main Circuit 690 V AC
  • Main Circuit 250 V DC
  • Rated Operational Current (Ie):4 A
  • Rated Operational Current AC-3 (Ie):4 A
  • Rated Operational Current AC-3e (Ie):4 A
  • Rated Operational Current DC-5 (Ie):4 A
  • Rated Frequency (f):Main Circuit 50 Hz
  • Main Circuit 60 Hz
  • Operating Frequency (fsw):0 ... 400 Hz
  • Rated Impulse Withstand Voltage (Uimp):Main Circuit 6 kV
  • Rated Insulation Voltage (Ui):690 V
  • Power Loss:at Rated Operating Conditions per Pole 0.7 ... 1.8 W
  • Number of Poles:3
  • Conventional Free-air Thermal Current (Ith):Main Circuit 4 A
  • Degree of Protection:Housing IP20
  • Main Circuit Terminals IP10
  • Pollution Degree:3
  • Electrical Durability:50000 cycle
  • Mechanical Durability:100000 cycle
  • Terminal Type:Screw Terminals
  • Connecting Capacity Main Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible 1/2x 0.75 ... 2.5 mm²
  • Rigid 1/2x 1 ... 4 mm²
  • Tightening Torque:Main Circuit 0.8 ... 1.2 N·m
  • Wire Stripping Length:Main Circuit 9 mm
  • Recommended Screw Driver:Pozidriv 2
  • Mounting Position:1 ... 6
  • Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
  • TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Minimum Mounting Distance:Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
  • Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
  • Electrical Conductive Board, Vertical 75 mm
  • Other Device Same Type, Horizontal 0 mm
  • Other Device Same Type, Vertical 150 mm
  • Actuator Type:Rotary Handle
  • Contact Position Indication:ON / OFF / TRIP
  • Standards:IEC/EN 60947-1
  • IEC/EN 60947-2
  • IEC/EN 60947-4-1
  • UL 60947-1
  • UL 60947-4-1
  • Remarks:UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
  • Technical UL/CSA
  • Short-Circuit Current Rating (SCCR):Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
  • Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA
  • Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
  • Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
  • Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
  • Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
  • Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
  • Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
  • Maximum Operating Voltage UL/CSA:Main Circuit 600 V AC
  • Horsepower Rating UL/CSA:(200 V AC) Three Phase 0.75 Hp
  • (208 V AC) Three Phase 0.75 Hp
  • (220 ... 240 V AC) Three Phase 1 Hp
  • (440 ... 480 V AC) Three Phase 2 Hp
  • (550 ... 600 V AC) Three Phase 3 Hp
  • Full Load Amps Motor Use:(200 V AC) Three Phase 4 A
  • (208 V AC) Three Phase 4 A
  • (220 ... 240 V AC) Three Phase 4 A
  • (440 ... 480 V AC) Three Phase 4 A
  • (550 ... 600 V AC) Three Phase 3.9 A
  • Locked Rotor Amps:(200 V AC) Three Phase 24 A
  • (208 V AC) Three Phase 24 A
  • (220 ... 240 V AC) Three Phase 24 A
  • (440 ... 480 V AC) Three Phase 24 A
  • (550 ... 600 V AC) Three Phase 25.6 A
  • General Use Rating UL/CSA:(600 V AC) 4 A
  • Connecting Capacity Main Circuit UL/CSA:Flexible 1/2x 16-12 AWG
  • Stranded 1/2x 16-12 AWG
  • Tightening Torque UL/CSA:Main Circuit 10 ... 12 in·lb
US $ 84.66
Quantity:
EA
Stock:
1 EA in stock
location
In Seller's Warehouse
Shop by Specification Table
You can find items with similar specifications from the table below.
Motor Starter
194 Items
motor-starter-img
Rated Current
6 A, 250 A, 480 A, 790 A, 320 A
Rated Voltage
220 V, 5 V, 208 V ac, 208 → 690 V ac, 240 V
Standards and Certifications
CE, CSA, CSA C22.2 No 14, C-Tick, EAC, EN 61131-2, EN/IEC 60068-2-27, EN/IEC 60068-2-30, EN/IEC 60068-2-6, EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-6, IEC 60068-2-27, IEC 61131-2, NOM, UL, UL 508, CCC, CE, CSA, UL, RoHS Compliant, ABS, ATEX, BV, CCC, CSA, CSA C22.2 No. 14, C-TICK, DNV, EAC, EN 60947-4-1, EN/IEC 60068, EN/IEC 60068-2-30, EN/IEC 60070-2-11, EN/IEC 60695-2-12, EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 61000-4-5, GL, IACS E10, IEC 60947-4-1, KERI, LROS (Lloyds register of shipping), NOM, RINA, RMRoS, UL, UL 508, UL 94, CSA, UL
Coil Voltage
110...240 V AC 110...220 V DC, 24 V AC, 380 V AC 50/60 Hz, 415 V AC 50/60 Hz, 220 V AC 50/60 Hz
Width
30 mm, 88 mm, 175 mm, 22.5 mm, 144 mm
Depth
146 mm, 135 mm, 165 mm, 114.5 mm, 170 mm
[Uimp] Rated Impulse Withstand Voltage
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1, 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1, 6 kV conforming to IEC 60947-6-2, 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1, 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Starter from ABB
Source & compare similar products
More from Motor Starter
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top