Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
施耐德电气 METSEPM2220 Easylogic PM2220,电力和能量计,高达 15 次谐波,液晶显示屏,RS485,1 类
施耐德电气 METSEPM2220 Easylogic PM2220,电力和能量计,高达 15 次谐波,液晶显示屏,RS485,1 类
Image
Image
Specifications
infotip-icon
View other Power & Energy Meters dimensions or variations
Please select at least one specification below.
Range
EasyLogic
[In] Rated Current
1 A 5 A
Type of Measurement
Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total
Display Type
Backlit LCD
Ambient Air Temperature for Operation
-10…60 °C
Width
96 mm
This spec is not available in the specification table.
Material
Polycarbonate
This spec is not available in the specification table.
Control Type
4 x button
This spec is not available in the specification table.
Local Signalling
Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: module operation and integrated communication
This spec is not available in the specification table.
Device Short Name
PM2220
This spec is not available in the specification table.
Product or Component Type
Power meter
This spec is not available in the specification table.
Product Name
EasyLogic PM2200
This spec is not available in the specification table.
Depth
76.09 mm total: 61.64 mm embedded:
This spec is not available in the specification table.
Device Application
Power monitoring Sub billing
This spec is not available in the specification table.
Mounting Support
Framework
This spec is not available in the specification table.
Height
96 mm
This spec is not available in the specification table.
Mounting Mode
Clip-on
This spec is not available in the specification table.
Accuracy class
Class 1 active energy conforming to IEC 62053-21 Class 1 reactive energy conforming to IEC 62053-24 Class 5 harmonic distorsion (I THD & U THD)
This spec is not available in the specification table.
Network Frequency
50 Hz 60 Hz
This spec is not available in the specification table.
Sampling rate
64 samples/cycle
This spec is not available in the specification table.
Measurement current
5…6000 mA
This spec is not available in the specification table.
Communication Port Protocol
Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
This spec is not available in the specification table.
Communication port support
Screw terminal block: RS485
This spec is not available in the specification table.
Connections - Terminals
Current transformer: screw connection (bottom) 6 Voltage inputs: screw connection (top) 4
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
Product certifications
CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 RCM EAC C-Tick
This spec is not available in the specification table.
IP Degree of Protection
IP54 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % at 50 °C
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-25…70 °C
This spec is not available in the specification table.
Operating Altitude
<= 2000 m
This spec is not available in the specification table.
Power quality analysis
total harmonic distortion up to the 15th harmonic
This spec is not available in the specification table.
Maximum power consumption in VA
6 VA at 277 V AC
This spec is not available in the specification table.
Ride-through time
100 ms 120 V AC typical 400 ms 230 V AC typical 50 ms 125 V DC typical
This spec is not available in the specification table.
Display resolution
128 x 128 pixels
This spec is not available in the specification table.
Measurement voltage
35…480 V AC 50/60 Hz between phases 20…277 V AC 50/60 Hz between phase and neutral 480…999000 V AC 50/60 Hz with external VT
This spec is not available in the specification table.
Frequency measurement range
45…65 Hz
This spec is not available in the specification table.
Measurement accuracy
Apparent power +/- 1 % Active energy +/- 1 % Reactive energy +/- 1 % Active power +/- 1 % Voltage +/- 0.5 % Power factor +/- 0.01 Current +/- 0.5 % Frequency +/- 0.05 %
This spec is not available in the specification table.
data recording
Time stamping Min/max for 8 parameters
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A
This spec is not available in the specification table.
Information displayed
Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) Voltage Current Frequency Energy consumption Harmonic distortion Power factor Active power Apparent power Reactive power Unbalanced in % Harmonic amplitude
This spec is not available in the specification table.
Flame retardance
V-0 conforming to UL 94
This spec is not available in the specification table.
Metering type
Active, reactive, apparent energy (signed, four quadrant) Current I, I1, I2, I3 Peak demand currents Peak demand power PM, QM, SM Unbalance current Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Demand power P, Q, S Voltage U, U21, U32, U13, V, V1, V2, V3 Apparent power S, S1, S2, S3 Calculated neutral current
This spec is not available in the specification table.
Measurement category
Category III 480 V Category II 480…600 V
This spec is not available in the specification table.
Maximum power consumption in W
3.3 W (power lines (AC)) 2 W at 277 V (power lines (DC))
This spec is not available in the specification table.
Compatibility Code
PM2220
This spec is not available in the specification table.
[Us] Rated Supply Voltage
44...277 V AC 45...65 Hz +/- 10 % 44...277 V DC +/- 10 %
This spec is not available in the specification table.
Mounting position
Vertical
This spec is not available in the specification table.
input impedance
Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm)
This spec is not available in the specification table.
Tamperproof of settings
Protected by access code
This spec is not available in the specification table.
Display colour
Monochrome
This spec is not available in the specification table.
Demand intervals
Configurable from 1 to 60 min
This spec is not available in the specification table.
Cybersecurity
Enable/disable communication ports
This spec is not available in the specification table.
Communication Service
Remote monitoring
This spec is not available in the specification table.
Provided equipment
1 x installation guide
This spec is not available in the specification table.
Electrical insulation class
Double insulation Class II
This spec is not available in the specification table.
Service life
7 year(s)
This spec is not available in the specification table.
language
Spanish French English Russian Portuguese German Chinese
This spec is not available in the specification table.
Function available
Real time clock
This spec is not available in the specification table.
产品描述
¥ 2654.37
数量:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Power & Energy Meters
38 Items
power-energy-meters-img
Poles Description
3P 1P + N 3P + N, 3P + N 3P 1P + N, 3P + N 1P + N 3P, 3P 3P + N 1P + N, 1P + N
[In] Rated Current
5 A 1 A, 1 A 5 A 10 A, 1 A 5 A, 125 A, 63 A
Type of Measurement
Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Apparent energy total Active and reactive energy total Apparent power total Active and reactive power total Current average Voltage average Frequency average Power factor average, Current Voltage Frequency Active and reactive power total Apparent power total Power factor total Active and reactive power per phase, rms Apparent power per phase, rms Power factor per phase, rms, Active and reactive power Apparent power Current Voltage Energy Power factor Frequency Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (U), Active and reactive energy Active and reactive power Current Voltage, Active energy Current Voltage Active power
Display Type
Backlit LCD, Remote LCD, TFT LCD, Without display, No Display
Standards
BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62052-23 IEC 62053-23:2020 EN 62052-23 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 BS EN 50470-3 EN 50470-3 BS EN 50470-1 EN 50470-1 ANSI C12.16, IEC 62053-22:2020 EN 50470-1 IEC 60529 IEC 61557-12:2015 UL 61010-1 EN 50470-3 IEC 62053-24 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015, BS EN 61557-12:2021 IEC 61557-12:2021 EN 61557-12:2021 BS EN 61326-1 IEC 61326-1 EN 61326-1 BS EN 62052-11:2020 IEC 62052-11:2020 EN 62052-11:2020 BS EN 62053-21 IEC 62053-21 EN 62053-21 BS EN 62053-22:2020 IEC 62053-22:2020 EN 62052-22 BS EN 62052-31:2015 IEC 62052-31:2015 EN 62052-31:2015 BS EN 61010-1:2010 EN 61010-1:2010 IEC 61010-1:2010 UL 61010-1:2010 BS EN 61010-2-30 IEC 61010-2-30 EN 61010-2-30 UL 61010-2-30 ANSI C12.20, IEC 62052-31 IEC 62053-21 IEC 62053-23 IEC 62052-11, EN 50470-3 IEC 61557-12:2015 IEC 62053-22:2020 IEC 62053-24 IEC 60529 EN 50470-1 UL 61010-1 ANSI C12.20 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015
Ambient Air Temperature for Operation
-25…70 °C, -25…55 °C - MID -25…70 °C - IEC -25…60 °C - IEC, -25…55 °C -20…55 °C, -25…55 °C - MID -25…70 °C - IEC, -25…70 °C - IEC
-