Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
施耐德电气 LV429562 Tmd - 紧凑型断路器 NSX100B
施耐德电气 LV429562 Tmd - 紧凑型断路器 NSX100B
Image
Image
Specifications
infotip-icon
View other Circuit Breaker dimensions or variations
Please select at least one specification below.
Ambient air temperature for operation
-25…70 °C
Protected Poles Description
3t
Network Type
AC
[In] Rated Current
63 A at 40 °C
Network Frequency
50/60 Hz
Standards
EN/IEC 60947
[Ui] Rated Insulation Voltage
800 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage
8 kV
Ip Degree Of Protection
IP40 conforming to IEC 60529
Pollution Degree
3 conforming to IEC 60664-1
Ambient Air Temperature For Storage
-50…85 °C
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz
Trip Unit Rating
63 A at 40 °C
Trip Unit Technology
Thermal-magnetic
This spec is not available in the specification table.
Trip Unit Protection Functions
LI
This spec is not available in the specification table.
Control Type
Toggle
This spec is not available in the specification table.
Mounting Mode
Fixed
This spec is not available in the specification table.
Trip Unit Name
TM-D
This spec is not available in the specification table.
Device Short Name
NSX100B
This spec is not available in the specification table.
Product Or Component Type
Circuit breaker
This spec is not available in the specification table.
Range
ComPact
This spec is not available in the specification table.
Product Name
ComPact NSX
This spec is not available in the specification table.
Range Of Product
ComPact NSX100...250
This spec is not available in the specification table.
Device Application
Distribution
This spec is not available in the specification table.
Connection Pitch
35 mm
This spec is not available in the specification table.
Neutral Position
Left
This spec is not available in the specification table.
Utilisation Category
Category A
This spec is not available in the specification table.
Suitability For Isolation
Yes conforming to EN/IEC 60947-2
This spec is not available in the specification table.
Mounting Support
Backplate
This spec is not available in the specification table.
Mechanical Durability
50000 cycles
This spec is not available in the specification table.
Electrical Durability
10000 cycles at 690 V In 20000 cycles at 690 V In/2 30000 cycles at 440 V In 50000 cycles at 440 V In/2
This spec is not available in the specification table.
Earth-Leakage Protection
Without
This spec is not available in the specification table.
Product Certifications
CCC EAC Marine
This spec is not available in the specification table.
Ik Degree Of Protection
IK07 conforming to IEC 62262
This spec is not available in the specification table.
Protection Type
L : for overload protection (thermal) I : for short-circuit protection (magnetic)
This spec is not available in the specification table.
Upside Connection
Front
This spec is not available in the specification table.
Downside Connection
Front
This spec is not available in the specification table.
Electrical Shock Protection Class
Class II
This spec is not available in the specification table.
Performance Level
B 25 kA 415 V AC
This spec is not available in the specification table.
Number Of Slots For Electrical Auxiliaries
5 slot(s)
This spec is not available in the specification table.
Overvoltage Category
Class II
This spec is not available in the specification table.
Relative Humidity
0…95 %
This spec is not available in the specification table.
Operating Altitude
0...2000 m without derating 2000 m...5000 m with derating
This spec is not available in the specification table.
[Ics] Rated Service Short-Circuit Breaking Capacity
20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
[Icu] Rated Ultimate Short-Circuit Breaking Capacity
15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Long-Time Pick-Up Adjustment Type Ir (Thermal Protection)
Adjustable
This spec is not available in the specification table.
[Ir] Long-Time Protection Pick-Up Adjustment Range
0.7...1 x In
This spec is not available in the specification table.
Long-Time Protection Delay Adjustment Type Tr
Fixed
This spec is not available in the specification table.
[Tr] Long-Time Protection Delay Adjustment Range
120…400 s at 1.5 x In 15 s at 6 x Ir
This spec is not available in the specification table.
Neutral Protection Settings
No protection (3t)
This spec is not available in the specification table.
Number Of Poles
4P
This spec is not available in the specification table.
Short-Time Protection Pick-Up Adjustment Type Isd
Fixed
This spec is not available in the specification table.
[Isd] Short-Time Protection Pick-Up Adjustment Range
500 A
This spec is not available in the specification table.
Short-Time Protection Delay Adjustment Type Tsd
Fixed
This spec is not available in the specification table.
产品描述


Highly Matched Items
View items that have the same or are a close match to the specifications of this item
来自 SCHNEIDER ELECTRIC 的 Circuit Breaker
寻找和比较同类产品
更多来自 Circuit Breaker
用更广泛的选择扩大您的搜索范围
最近浏览过的 产品
比较和参考以前查看的项目
Image
最佳