Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
施耐德电气 LTMR100EBD 电机控制器、Tesys T、电机管理、以太网/IP、Modbus/TCP、6 个逻辑输入、3 个逻辑输出、5 至 100A、24VDC
施耐德电气 LTMR100EBD 电机控制器、Tesys T、电机管理、以太网/IP、Modbus/TCP、6 个逻辑输入、3 个逻辑输出、5 至 100A、24VDC
Image
Image
Specifications
infotip-icon
View other Motor Starter dimensions or variations
Please select at least one specification below.
Operating Temperature
-20…60 °C
Standards and Certifications
IEC 60947-4-1 UL 508 IACS E10 EN 60947-4-1 CSA C22.2 No 14
Width
91 mm
Depth
122.5 mm
[Ui] Rated Insulation Voltage
690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508
[Uimp] Rated Impulse Withstand Voltage
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
Ip Degree Of Protection
IP20
Height
61 mm
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys T
This spec is not available in the specification table.
Device Short Name
LTMR
This spec is not available in the specification table.
Device Application
Equipment monitoring and control
This spec is not available in the specification table.
Connection Pitch
5.08 mm
This spec is not available in the specification table.
Compatibility Code
LTMR
This spec is not available in the specification table.
Measurement Current
5…100 A
This spec is not available in the specification table.
Connections - Terminals
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…80 °C
This spec is not available in the specification table.
Operating Altitude
<= 2000 m without derating
This spec is not available in the specification table.
Tightening Torque
Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
This spec is not available in the specification table.
Measurement Accuracy
5...15 % earth fault current internal measurement 1 % voltage (100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 5 % active and reactive power 0,02 current
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
This spec is not available in the specification table.
Associated Fuse Rating
4 A gG for output 0.5 A gG for control circuit
This spec is not available in the specification table.
Maximum Operating Rate
1800 cyc/h
This spec is not available in the specification table.
Product Certifications
C-Tick KERI BV ABS NOM LROS (Lloyds register of shipping) RMRoS RINA GL DNV ATEX CCC EAC UL CSA
This spec is not available in the specification table.
Protective Treatment
12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068
This spec is not available in the specification table.
Mechanical Robustness
Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
This spec is not available in the specification table.
Fire Resistance
650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94
This spec is not available in the specification table.
Logic Input Number
6
This spec is not available in the specification table.
Input Current
7 mA
This spec is not available in the specification table.
Current State 0 Guaranteed
Logic input: < 5 V and <= 15 mA for 5 ms
This spec is not available in the specification table.
Current State 1 Guaranteed
Logic input: < 15 V and 2...15 mA for 15 ms
This spec is not available in the specification table.
Maximum Output Switching Frequency
2 Hz
This spec is not available in the specification table.
Contacts Type And Composition
1 NO + 1 NC fault signal 3 NO
This spec is not available in the specification table.
Metering Type
Average current Iavg Earth-fault current Temperature Phase current I1, I2, I3 RMS Imbalance current
This spec is not available in the specification table.
[Us] Rated Supply Voltage
24 V DC
This spec is not available in the specification table.
Supply Voltage Limits
20.4…26.24 V DC
This spec is not available in the specification table.
Protection Type
Locked rotor Overload Thermal overload protection Earth-leakage protection Reverse polarity protection Overload (long time) Power factor variation Phase unbalance Load fluctuation Phase failure Thermal protection
This spec is not available in the specification table.
Current Consumption
56...127 mA
This spec is not available in the specification table.
Load Current
5 A at 250 V AC for logic output 5 A at 30 V DC for logic output
This spec is not available in the specification table.
Web Services
Web server
This spec is not available in the specification table.
Communication Port Protocol
Modbus TCP/EtherNet/IP
This spec is not available in the specification table.
Bus Type
Ethernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs
This spec is not available in the specification table.
Short-Circuit Withstand
100 kA conforming to EN/IEC 60947-4-1
This spec is not available in the specification table.
Network And Machine Diagnosis Type
Fault recording Trip context information Waiting time after overload tripping Trip history information Running hours counter/operating time Motor control command recording Starting current and time Phase fault and earth fault trip counters Event recording Remaining operating time before overload tripping
This spec is not available in the specification table.
Permissible Power
480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
This spec is not available in the specification table.
产品描述
¥ 13461.98
数量:
EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
来自 SCHNEIDER ELECTRIC 的 Motor Starter
寻找和比较同类产品
更多来自 Motor Starter
用更广泛的选择扩大您的搜索范围
最近浏览过的 产品
比较和参考以前查看的项目
Image
最佳