Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
施耐德电气 LC1D40ABBE 接触器,Tesys Deca,3P(3NO),AC-3/AC-3e,<=440V,40A,24VDC 线圈,Everlink Btr 螺钉
施耐德电气 LC1D40ABBE 接触器,Tesys Deca,3P(3NO),AC-3/AC-3e,<=440V,40A,24VDC 线圈,Everlink Btr 螺钉
Image
Image
Specifications
infotip-icon
View other Contactors dimensions or variations
Please select at least one specification below.
Device Short Name
LC1D
Range Of Product
TeSys Deca
Depth
120 mm
Pole Contact Composition
3 NO
Poles Description
3P
Contactor Application
Motor control Resistive load
Compatibility Code
LC1D
This spec is not available in the specification table.
Standards
EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC 60335-1
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947
This spec is not available in the specification table.
Mounting Support
Plate Rail
This spec is not available in the specification table.
Connections - Terminals
Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: solid Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: solid Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible without cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible without cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible with cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
This spec is not available in the specification table.
Height
122 mm
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 front face conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Mechanical Durability
6 Mcycles
This spec is not available in the specification table.
Electrical Durability
2 Mcycles 35 A AC-3 at Ue <= 440 V 0.7 Mcycles 60 A AC-1 at Ue <= 440 V 2 Mcycles 35 A AC-3e at Ue <= 440 V
This spec is not available in the specification table.
Operating Altitude
0...3000 m
This spec is not available in the specification table.
Tightening Torque
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - with screwdriver pozidriv No 2 Control circuit: 1.7 N.m - with screwdriver pozidriv No 2
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
Power circuit: <= 690 V AC 25...400 Hz
This spec is not available in the specification table.
[Ie] Rated Operational Current
60 A (at <60 °C) at <= 440 V AC-1 for power circuit 40 A (at <60 °C) at <= 440 V AC-3 for power circuit 40 A (at <60 °C) at <= 440 V AC-3e for power circuit
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
24 V DC
This spec is not available in the specification table.
Heat dissipation
0.5 W
This spec is not available in the specification table.
Range
TeSys TeSys Deca
This spec is not available in the specification table.
Utilisation Category
AC-1 AC-3 AC-3e
This spec is not available in the specification table.
Motor Power Kw
11 kW at 220...230 V AC 50 Hz (AC-3) 18.5 kW at 380...400 V AC 50 Hz (AC-3) 22 kW at 415 V AC 50 Hz (AC-3) 22 kW at 440 V AC 50 Hz (AC-3) 22 kW at 500 V AC 50 Hz (AC-3) 30 kW at 660...690 V AC 50 Hz (AC-3) 11 kW at 220...230 V AC 50 Hz (AC-3e) 18.5 kW at 380...400 V AC 50 Hz (AC-3e) 22 kW at 415 V AC 50 Hz (AC-3e) 22 kW at 440 V AC 50 Hz (AC-3e) 22 kW at 500 V AC 50 Hz (AC-3e) 30 kW at 660...690 V AC 50 Hz (AC-3e)
This spec is not available in the specification table.
Protective Cover
With
This spec is not available in the specification table.
Motor Power Hp
3 hp at 115 V AC 60 Hz for 1 phase motors 5 hp at 230/240 V AC 60 Hz for 1 phase motors 10 hp at 200/208 V AC 60 Hz for 3 phases motors 10 hp at 230/240 V AC 60 Hz for 3 phases motors 30 hp at 460/480 V AC 60 Hz for 3 phases motors 30 hp at 575/600 V AC 60 Hz for 3 phases motors
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
60 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit
This spec is not available in the specification table.
Irms Rated Making Capacity
800 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
This spec is not available in the specification table.
Rated Breaking Capacity
800 A at 440 V for power circuit conforming to IEC 60947
This spec is not available in the specification table.
[Icw] Rated Short-Time Withstand Current
72 A 40 °C - 10 min for power circuit 165 A 40 °C - 1 min for power circuit 320 A 40 °C - 10 s for power circuit 720 A 40 °C - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
This spec is not available in the specification table.
Associated Fuse Rating
80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1
This spec is not available in the specification table.
Average Impedance
1.5 mOhm - Ith 60 A 50 Hz for power circuit
This spec is not available in the specification table.
Power Dissipation Per Pole
5.4 W AC-1 2.4 W AC-3 2.4 W AC-3e
This spec is not available in the specification table.
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
This spec is not available in the specification table.
Control Circuit Type
DC DC low consumption
This spec is not available in the specification table.
Coil Technology
Built-in bidirectional peak limiting
This spec is not available in the specification table.
Control Circuit Voltage Limits
<= 0.1 Uc (-40…70 °C):drop-out DC 0.8...1.2 Uc (-40…60 °C):operational DC 1...1.2 Uc (60…70 °C):operational DC
This spec is not available in the specification table.
Operating Time
55...65 ms closing 20...120 ms opening (date code >= 17221) 20...80 ms opening (date code >= 18011)
This spec is not available in the specification table.
Auxiliary Contact Composition
3600 cyc/h 60 °C
This spec is not available in the specification table.
Maximum Operating Rate
1 NO + 1 NC
This spec is not available in the specification table.
Signalling Circuit Frequency
25...400 Hz
This spec is not available in the specification table.
Auxiliary Contacts Type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
This spec is not available in the specification table.
Minimum Switching Voltage
17 V for signalling circuit
This spec is not available in the specification table.
Minimum Switching Current
5 mA for signalling circuit
This spec is not available in the specification table.
Insulation Resistance
> 10 MOhm for signalling circuit
This spec is not available in the specification table.
Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
This spec is not available in the specification table.
Climatic Withstand
conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat
This spec is not available in the specification table.
Permissible Ambient Air Temperature Around The Device
-40…60 °C 60…70 °C with derating
This spec is not available in the specification table.
Fire Resistance
850 °C conforming to IEC 60695-2-1
This spec is not available in the specification table.
Flame Retardance
V1 conforming to UL 94
This spec is not available in the specification table.
Mechanical Robustness
Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor open (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms)
This spec is not available in the specification table.
Inrush Power In W
11 W (at 20 °C)
This spec is not available in the specification table.
Hold-In Power Consumption In W
0.5 W at 20 °C
This spec is not available in the specification table.
产品描述
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
来自 SCHNEIDER ELECTRIC 的 Contactors
寻找和比较同类产品
更多来自 Contactors
用更广泛的选择扩大您的搜索范围
最近浏览过的 产品
比较和参考以前查看的项目
Image
最佳