Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
施耐德电气 ABLS1A24200 稳压电源,100 至 240V 交流,24V,20A,单相,优化
施耐德电气 ABLS1A24200 稳压电源,100 至 240V 交流,24V,20A,单相,优化
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Power Supply dimensions or variations
Please select at least one specification below.
Standards
IEC 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 EN/IEC 62368-1
Connections - Terminals
Screw connection: 0.75...4 mm², (AWG 20...AWG 12) without wire end ferrule for output Screw connection: 0.75...4 mm², (AWG 20...AWG 14) with wire end ferrule for output Screw connection: 0.75...4 mm², (AWG 18...AWG 12) without wire end ferrule for input Screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input
Product Certifications
CE CUL listed CUL recognized RCM CB Scheme EAC KC
Inrush Current
45.0 A at 115 V 90.0 A at 230 V
Status Led
1 LED (green) output voltage
Enclosure Material
Aluminium
Power Supply Output Current
20 A
Product Or Component Type
Power supply
This spec is not available in the specification table.
Range Of Product
Modicon Power Supply
This spec is not available in the specification table.
Mounting Support
Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Double-profile DIN rail
This spec is not available in the specification table.
Efficiency
85 % at 115 V AC 88 % at 230 V AC
This spec is not available in the specification table.
Overvoltage Category
II
This spec is not available in the specification table.
Ip Degree Of Protection
IP20
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Ambient Air Temperature For Operation
-20…40 °C without derating mounting position A 115 V AC < 2000 m -20…50 °C without derating mounting position A 230 V AC < 2000 m 40…70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 2000 m 50���70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 2000 m
This spec is not available in the specification table.
Operating Altitude
< 5000 m
This spec is not available in the specification table.
Shock Resistance
150 m/s² for 11 ms
This spec is not available in the specification table.
Vibration Resistance
3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6 10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6
This spec is not available in the specification table.
Dielectric Strength
3000 V AC with input to output
This spec is not available in the specification table.
Electrical Shock Protection Class
Class I
This spec is not available in the specification table.
Output Voltage
24 V DC
This spec is not available in the specification table.
Current Consumption
< 5.4 A 115 V AC < 2.7 A 230 V AC < 5 A 140 V DC
This spec is not available in the specification table.
Electromagnetic Emission
Conducted emissions conforming to IEC 61000-6-3 Radiated emissions conforming to IEC 61000-6-4
This spec is not available in the specification table.
Maximum Leakage Current
1 mA 240 V AC
This spec is not available in the specification table.
Supply
SELV conforming to IEC 60950-1 SELV conforming to IEC 60204-1 SELV conforming to IEC 60364-4-41
This spec is not available in the specification table.
Power Supply Type
Regulated switch mode
This spec is not available in the specification table.
Variant Option
Optimized
This spec is not available in the specification table.
Nominal Input Voltage
100...240 V AC single phase 100...240 V AC phase to phase 140...340 V DC
This spec is not available in the specification table.
Rated Power In W
480 W
This spec is not available in the specification table.
Input Voltage Limits
85...264 V AC without temperature derating 120...375 V DC without temperature derating
This spec is not available in the specification table.
Nominal Network Frequency
50…60 Hz
This spec is not available in the specification table.
Network System Compatibility
TN TT IT
This spec is not available in the specification table.
Input Protection Type
Integrated fuse (not interchangeable) 10 A External protection (recommended) 20 A Curve C External protection (recommended) 16 A Curve B External protection (recommended) 13 A Curve C
This spec is not available in the specification table.
Power Factor
0.95 at 115 V AC 0.95 at 230 V AC
This spec is not available in the specification table.
Output Voltage Adjustment
22...28 V
This spec is not available in the specification table.
Power Dissipation In W
60 W
This spec is not available in the specification table.
Turn-On Time
< 1.5 s
This spec is not available in the specification table.
Holding Time
> 20 ms 115 V AC > 20 ms 230 V AC
This spec is not available in the specification table.
Startup With Capacitive Loads
8000 µF
This spec is not available in the specification table.
Residual Ripple
< 120 mV
This spec is not available in the specification table.
Meantime Between Failure [Mtbf]
700000 h at 25 °C, full load conforming to SR 332
This spec is not available in the specification table.
Output Protection Type
Against overload and short-circuits, protection technology: automatic reset Against over temperature, protection technology: manual reset Against overvoltage, protection technology: manual reset
This spec is not available in the specification table.
Line And Load Regulation
< 0.5 % at 0 to 100 % load at 25 °C < 1 % at full voltage range in line at 25 °C
This spec is not available in the specification table.
Output Coupling
Parallel Serial
This spec is not available in the specification table.
Electromagnetic Immunity
Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2 Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2 Immunity to conducted RF disturbances - test level: 15 V/m (80 MHz...2 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to IEC 61000-4-3 Immunity to conducted RF disturbances - test level: 5 V/m (2.7...6 GHz) conforming to IEC 61000-4-3 Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5 Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5 Immunity to conducted RF disturbances - test level: 15 V (0.15...80 MHz) conforming to IEC 61000-4-6 Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to IEC 61000-4-8 Immunity to voltage dips conforming to IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to IEC 61000-3-2 conforming to EN 55016-1-2 conforming to EN 55016-2-1
This spec is not available in the specification table.
产品描述
¥ 2670.45
数量:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Power Supply
23 Items
power-supply-img
Standards
CSA C22.2 No 60950-1 UL 508 EN/IEC 62368-1, IEC 62368-1 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 CSA C22.2 No 62368-1 UL 508 CSA C22.2 No 107.1 EN/IEC 62368-1, IEC 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-3 IEC 61000-6-4 IEC 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 IEC 60335-1 EN/IEC 62368-1, UL 508 CSA C22.2 No 60950-1 EN/IEC 62368-1, CSA C22.2 No 60950-1 UL 508
Connections - Terminals
Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection, Screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) for output Screw connection: 0.75...2.5 mm², (AWG 18...AWG 14) for input, For ground connection: screw type terminals, connection capacity: 1 x 4 mm² AWG 12, Removable screw terminal block: 2 x 2.5 mm², for diagnostic relay Screw type terminals: 3 x 0.5...3 x 4 mm², (AWG 22...AWG 12) for input connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for input ground connection Screw type terminals: 4 x 0.5...4 x 4 mm², (AWG 22...AWG 12) for output connection Screw type terminals: 1 x 0.5...1 x 4 mm², (AWG 22...AWG 12) for output ground connection, For output connection: screw type terminals, connection capacity: 2 x 0.5...2 x 10 mm² AWG 20...AWG 8 For input connection: screw type terminals, connection capacity: 4 x 0.5...4 x 10 mm² AWG 20...AWG 8 For diagnostic relay: removable screw terminal block, connection capacity: 1 x 2.5 mm² AWG 14
Product Certifications
CCSAus EAC UL RCM KC, CE CUL listed CUL recognized RCM CB Scheme EAC KC, CE CULus EAC RCM CB Scheme KC, CCSAus EAC KC RCM UL, EAC RCM
Inrush Current
45 A at 100...240 V AC, 35 A at 115 V 70 A at 230 V, 40.0 A at 115 V 80.0 A at 230 V, 50 A at 100...240 V AC, 30 A
Power Supply Output Current
2.2 A, 2.5 A, 6.25 A, 3.13 A, 5 A
-
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
来自 SCHNEIDER ELECTRIC 的 Power Supply
寻找和比较同类产品
更多来自 Power Supply
用更广泛的选择扩大您的搜索范围
最近浏览过的 产品
比较和参考以前查看的项目
Image
最佳