Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
SCHNEIDER ELECTRIC/施耐德电气 A9N61517 微型断路器 (MCB),ACTI9 C60H-DC,1P,40A,C 曲线,6KA (IEC/EN 60947-2)
SCHNEIDER ELECTRIC/施耐德电气 A9N61517 微型断路器 (MCB),ACTI9 C60H-DC,1P,40A,C 曲线,6KA (IEC/EN 60947-2)
Image
Image
技术数据表
Specifications
infotip-icon
View other Miniature Circuit Breakers - MCBs dimensions or variations
Please select at least one specification below.
Standards
EN/IEC 60898-1, EN/IEC 60947-2, IEC 60529
Breaking Capacity
10kA at 220VDC
Rated Current
40A
This spec is not available in the specification table.
Poles
1P
This spec is not available in the specification table.
Trip Curve
C
This spec is not available in the specification table.
Weight
0.128kg
This spec is not available in the specification table.
Operating Temperature Range
-25°C to 70°C
This spec is not available in the specification table.
Dimensions
2 pitches of 9mm
This spec is not available in the specification table.
Rated Voltage
250VDC
This spec is not available in the specification table.
Mounting Type
DIN Rail
This spec is not available in the specification table.
产品描述

SCHNEIDER ELECTRIC Miniature Circuit Breaker (mcb), Acti9 C60H-DC, 1P, 40A, C Curve, 6kA (IEC/EN 60947-2) A9N61517

  • This Acti9 C60H-DC is a low voltage direct current miniature circuit breaker (MCB). It has 1P, rated current 40A and C tripping curve. The rated short circuit breaking capacity goes up to 10kA at 220VDC conforming to EN 60947-2 standard and 10kA at 220VDC conforming to EN 60947-2 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. It offers VisiTrip for safety during maintenance and VisiSafe to reduce intervention time. The Acti9 C60H-DC is used in direct current circuit (industrial control and automation, transport, renewable energy). This device is dedicated to industrial control, automations, transport and renewable energy applications. It has an electrical endurance going up to 3000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 250VDC. The Ui rated insulation voltage is 500VDC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The weight is 0.128kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 85°C.
¥ 2772.13
Image
该产品无效。
存货数量少于最小订货量。
数量:
EA
Img
最小12 EA单位起订量
Img
12 EA 一捆
Stock:
6 EA 库存
location
In Seller's Warehouse
Shop by Specification Table
You can find items with similar specifications from the table below.
Miniature Circuit Breakers - MCBs
714 Items
miniature-circuit-breakers-mcbs-img
Range
Acti 9, MASTERPACT NW, Multi 9, PowerPact, TeSys
Poles Description
3P+N, 1P, 1P+N, 2P, 3P
[In] Rated Current
1.6 A, 3.5 A, 3.2 kA, 40 A, 25 A
Breaking Capacity
25 kA, 30 kA, 50 kA, 15 kA, 30 kA, 15 kA
Standards
EN 60947-2 IEC 60947-2 IEC 60898-1 EN 60898-1, EN/IEC 60947-2 EN/IEC 60898-1, EN/IEC 60898-1 EN/IEC 60947-2, IEC 60947-2 EN 60898-1 EN 60947-2 IEC 60898-1, EN 60898-1 IEC 60898-1 EN 60947-2 IEC 60947-2
Magnetic Tripping Limit
10...14 x In, 8.5 x In +/- 20 % AC 12 x In +/- 20 % DC, 3...5 x In, 12 x In +/- 20 %, 4 x In +/- 20 %
Connection - Terminals
Tunnel type terminals (downstream) 0.5…35 mm² rigid, Tunnel type terminals (downstream) 0.5…25 mm² rigid Tunnel type terminals (upstream) 0.5…25 mm² rigid Tunnel type terminals (downstream) 0.5…16 mm² flexible Tunnel type terminals (upstream) 0.5…16 mm² flexible Tunnel type terminals (downstream) 0.5…16 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…16 mm² flexible with ferrule, Tunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible, Tunnel type terminal (top or bottom) 1…35 mm² rigid Tunnel type terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible Tunnel type terminals (downstream) 0.5…25 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…25 mm² flexible with ferrule
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
来自 SCHNEIDER ELECTRIC 的 Miniature Circuit Breakers - MCBs
寻找和比较同类产品
更多来自 Miniature Circuit Breakers - MCBs
用更广泛的选择扩大您的搜索范围
最近浏览过的 产品
比较和参考以前查看的项目
Image
最佳