Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
SCHNEIDER ELECTRIC/施耐德电气 A9K12363 63A - ACTI 9 K60H 3P
SCHNEIDER ELECTRIC/施耐德电气 A9K12363 63A - ACTI 9 K60H 3P
Image
Image
技术数据表
产品描述

SCHNEIDER ELECTRIC Acti 9 K60H 3P - 63A - C Curve 10000 A

Main

  • Device application Distribution
  • Range Acti9
  • Product name Acti9 K60
  • Product or component type
  • Miniature circuit-breaker
  • Device short name K60H
  • Poles description 3P
  • Number of protected poles 3
  • [In] rated current 63 A
  • Network type AC
  • Trip unit technology Thermal-magnetic
  • Curve code C
  • Breaking capacity 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/
  • IEC 60898-1
  • Utilisation category Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN/IEC 60898-1
  • Standards EN/IEC 60898-1
  • Product certifications VDE

Complementary

  • Network frequency 50/60 Hz
  • Magnetic tripping limit 5...10 x In
  • [Ics] rated service breaking capacity 10000 A 75 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
  • Limitation class 3 conforming to EN/IEC 60898-1
  • [Ui] rated insulation voltage 440 V AC 50/60 Hz conforming to EN/IEC 60898-1
  • [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60898-1
  • Contact position indicator No
  • Control type Toggle
  • Local signalling Without
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar and distribution block compatibility Downside: biconnect 9 mm pitches 6
  • Height 81 mm
  • Width 54 mm
  • Depth 70 mm
  • Net weight 0.36 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Tunnel type terminal (top or bottom) 1…35 mm² rigid
  • Tunnel type terminal (top or bottom) 1…25 mm² flexible
  • Wire stripping length 14 mm for top or bottom connection
  • Tightening torque 3.5 N.m top or bottom
  • Earth-leakage protection Without 2

Environment

  • IP degree of protection IP20 conforming to IEC 60529
  • Pollution degree 2 conforming to IEC 60898-1
  • Overvoltage category II
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % at 55 °C
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -25…70 °C
  • Ambient air temperature for storage -25…85 °C

Packing Units

  • Unit Type of Package 1 PCE
  • Number of Units in Package 1 1
  • Package 1 Height 7.3 cm
  • Package 1 Width 5.3 cm
  • Package 1 Length 8.5 cm
  • Package 1 Weight 0.35 kg
  • Unit Type of Package 2 S03
  • Number of Units in Package 2 48
  • Package 2 Height 30 cm
  • Package 2 Width 30 cm
  • Package 2 Length 40 cm
  • Package 2 Weight 16.8 kg


¥ 1520.63
Units折扣单价
1-¥ 380.16
数量:
EA
Img
最小4 EA单位起订量
Img
4 EA 一捆
Image
需要 60 个工作日的交货时间。
物品将在指定的交货时间内准备好发货。
Shop by Specification Table
You can find items with similar specifications from the table below.
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
来自 SCHNEIDER ELECTRIC 的 Miniature Circuit Breakers - MCBs
寻找和比较同类产品
更多来自 Miniature Circuit Breakers - MCBs
用更广泛的选择扩大您的搜索范围
最近浏览过的 产品
比较和参考以前查看的项目
Image