Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
SCHNEIDER ELECTRIC/施耐德电气 A9K01340 40 A - ACTI 9 K60N 3P
SCHNEIDER ELECTRIC/施耐德电气 A9K01340 40 A - ACTI 9 K60N 3P
Image
Image
技术数据表
产品描述

SCHNEIDER ELECTRIC Acti 9 K60N 3P - 40 a - B Curve 6000 A


Main

  • Device application Distribution
  • Range Acti9
  • Product name Acti9 K60
  • Product or component
  • type
  • Miniature circuit-breaker
  • Device short name K60N
  • Poles description 3P
  • Number of protected poles 3
  • [In] rated current 40 A
  • Network type AC
  • Trip unit technology Thermal-magnetic
  • Curve code B
  • Breaking capacity 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/
  • IEC 60898-1
  • Utilisation category Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN/IEC 60898-1
  • Standards EN/IEC 60898-1
  • Product certifications VDE
  • OVE

Complementary

  • Network frequency 50/60 Hz
  • Magnetic tripping limit 3...5 x In
  • [Ics] rated service breaking capacity 6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
  • Limitation class 3 conforming to EN/IEC 60898-1
  • [Ui] rated insulation voltage 440 V AC 50/60 Hz conforming to EN/IEC 60898-1
  • [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60898-1
  • Contact position indicator No
  • Control type Toggle
  • Local signalling Without
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar and distribution block compatibility Downside: biconnect
  • 9 mm pitches 6
  • Height 81 mm
  • Width 54 mm
  • Depth 70 mm
  • Net weight 0.36 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Tunnel type terminals (downstream) 0.5…35 mm² rigid
  • Tunnel type terminals (upstream) 0.5…35 mm² rigid
  • Tunnel type terminals (downstream) 0.5…25 mm² flexible
  • Tunnel type terminals (upstream) 0.5…25 mm² flexible
  • Wire stripping length 14 mm for top or bottom connection
  • Tightening torque 3.5 N.m top or bottom
  • Earth-leakage protection Without

Environment

  • IP degree of protection IP20 conforming to IEC 60529
  • Pollution degree 2 conforming to IEC 60898-1
  • 2 conforming to EN 60898-1
  • Overvoltage category II
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % at 55 °C
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -25…70 °C
  • Ambient air temperature for storage -40…70 °C

Packing Units

  • Unit Type of Package 1 PCE
  • Number of Units in Package 1 1
  • Package 1 Height 5.4 cm
  • Package 1 Width 7.5 cm
  • Package 1 Length 8.5 cm
  • Package 1 Weight 357.0 g
  • Unit Type of Package 2 BB1
  • Number of Units in Package 2 4
  • Package 2 Height 8.0 cm
  • Package 2 Width 9.0 cm
  • Package 2 Length 23.0 cm
  • Package 2 Weight 1.478 kg
  • Unit Type of Package 3 S03
  • Number of Units in Package 3 48
  • Package 3 Height 30.0 cm
  • Package 3 Width 30.0 cm
  • Package 3 Length 40.0 cm
  • Package 3 Weight 18.257 kg
¥ 169.22
Image
需要 15 个工作日的交货时间。
物品将在指定的交货时间内准备好发货。
数量:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Miniature Circuit Breakers - MCBs
714 Items
miniature-circuit-breakers-mcbs-img
Range
TeSys, Square D, Acti 9, MASTERPACT NW, PowerPact
Poles Description
2P, 1P, 3P+N, 4P, 3P
[In] Rated Current
3 A, 1.6 A, 3.5 A, 3.2 kA, 5 A
Breaking Capacity
25 kA, 20 kA, 30 kA, 20 kA, 3 kA, 15 kA, 30 kA
Standards
EN 60947-2 IEC 60947-2 IEC 60898-1 EN 60898-1, EN/IEC 60898-1, EN 60947-2 EN 60898-1 IEC 60898-1 IEC 60947-2, IEC 60947-2 EN 60898-1 EN 60947-2 IEC 60898-1, EN 60898-1 IEC 60898-1 EN 60947-2 IEC 60947-2
Magnetic Tripping Limit
8 x In +/- 20 %, 5...10 x In, 4 x In +/- 20 %, 10...14 x In, 12 x In +/- 20 %
Connection - Terminals
Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible, Tunnel type terminals (downstream) 0.5…25 mm² rigid Tunnel type terminals (upstream) 0.5…25 mm² rigid Tunnel type terminals (downstream) 0.5…16 mm² flexible Tunnel type terminals (upstream) 0.5…16 mm² flexible Tunnel type terminals (downstream) 0.5…16 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…16 mm² flexible with ferrule, Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminal (top or bottom) 1…35 mm² rigid Tunnel type terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible Tunnel type terminals (downstream) 0.5…25 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…25 mm² flexible with ferrule