Shopping List
购物清单
CNY - ¥
Image
/
/
/
/
施耐德电气 A9K01332 32 a - Acti 9 K60N 3P
施耐德电气 A9K01332 32 a - Acti 9 K60N 3P
Image
Image
Specifications
infotip-icon
View other Miniature Circuit Breakers - MCBs dimensions or variations
Please select at least one specification below.
Range
Acti 9
Poles Description
3P
Network Type
AC
Number of Protected Poles
3
[In] Rated Current
32 A
Curve Code
B
Breaking Capacity
6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Standards
EN/IEC 60898-1
Magnetic Tripping Limit
3...5 x In
Connection - Terminals
Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible
IP Degree of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature for Operation
-25…70 °C
Mechanical Durability
20000 cycles
Ambient Air Temperature for Storage
-40…70 °C
Electrical Durability
10000 cycles
Tightening Torque
3.5 N.m top or bottom
Colour
White
This spec is not available in the specification table.
Width
54 mm
This spec is not available in the specification table.
Trip Unit Technology
Thermal-magnetic
This spec is not available in the specification table.
Control Type
Toggle
This spec is not available in the specification table.
Device Short Name
K60N
This spec is not available in the specification table.
Product Name
Acti9 K60
This spec is not available in the specification table.
Depth
70 mm
This spec is not available in the specification table.
Device Application
Distribution
This spec is not available in the specification table.
Mounting Mode
Fixed
This spec is not available in the specification table.
Network Frequency
50/60 Hz
This spec is not available in the specification table.
Utilisation Category
Category A conforming to IEC 60947-2
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to EN/IEC 60898-1
This spec is not available in the specification table.
[Ics] Rated Service Breaking Capacity
6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz
This spec is not available in the specification table.
Limitation Class
3 conforming to EN/IEC 60898-1
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
440 V AC 50/60 Hz conforming to EN/IEC 60898-1
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
4 kV conforming to EN/IEC 60898-1
This spec is not available in the specification table.
Contact Position Indicator
No
This spec is not available in the specification table.
Mounting Support
DIN rail
This spec is not available in the specification table.
Local Signalling
Without
This spec is not available in the specification table.
Overvoltage Category
II
This spec is not available in the specification table.
Comb Busbar and Distribution Block Compatibility
Downside: biconnect
This spec is not available in the specification table.
9 mm Pitches
6
This spec is not available in the specification table.
Height
81 mm
This spec is not available in the specification table.
Pollution Degree
2 conforming to IEC 60898-1 2 conforming to EN 60898-1
This spec is not available in the specification table.
Relative Humidity
95 % at 55 °C
This spec is not available in the specification table.
Operating Altitude
0...2000 m
This spec is not available in the specification table.
Wire Stripping Length
14 mm for top or bottom connection
This spec is not available in the specification table.
Earth-Leakage Protection
Without
This spec is not available in the specification table.
Product certifications
OVE VDE
This spec is not available in the specification table.
Tropicalisation
2 conforming to IEC 60068-1
This spec is not available in the specification table.
产品描述
¥ 169.22
数量:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Miniature Circuit Breakers - MCBs
714 Items
miniature-circuit-breakers-mcbs-img
Range
TeSys, Resi 9, MASTERPACT NW, Easy 9, PowerPact
Poles Description
3P, 1P+N, 3P+N, 1P, 2P
[In] Rated Current
3 A, 1.6 A, 3.5 A, 3.2 kA, 24 A
Breaking Capacity
10 kA, 25 kA, 30 kA, 6 kA, 3000 A
Standards
EN 60947-2 IEC 60947-2 IEC 60898-1 EN 60898-1, EN/IEC 60898-1, EN/IEC 60947-2 EN/IEC 60898-1, IEC 60947-2 EN 60898-1 EN 60947-2 IEC 60898-1, EN 60898-1 IEC 60898-1 EN 60947-2 IEC 60947-2
Magnetic Tripping Limit
12 x In +/- 20 %, 3...5 x In, 4 x In +/- 20 %, 5...10 x In, 10...14 x In
Connection - Terminals
Tunnel type terminals (downstream) 0.5…25 mm² rigid Tunnel type terminals (upstream) 0.5…25 mm² rigid Tunnel type terminals (downstream) 0.5…16 mm² flexible Tunnel type terminals (upstream) 0.5…16 mm² flexible Tunnel type terminals (downstream) 0.5…16 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…16 mm² flexible with ferrule, Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminal (top or bottom) 1…35 mm² rigid Tunnel type terminal (top or bottom) 1…25 mm² flexible, Tunnel type terminals (downstream) 0.5…35 mm² rigid Tunnel type terminals (upstream) 0.5…35 mm² rigid Tunnel type terminals (downstream) 0.5…25 mm² flexible Tunnel type terminals (upstream) 0.5…25 mm² flexible Tunnel type terminals (downstream) 0.5…25 mm² flexible with ferrule Tunnel type terminals (upstream) 0.5…25 mm² flexible with ferrule, Tunnel type terminals (downstream) 0.5…35 mm² rigid
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
来自 SCHNEIDER ELECTRIC 的 Miniature Circuit Breakers - MCBs
寻找和比较同类产品
更多来自 Miniature Circuit Breakers - MCBs
用更广泛的选择扩大您的搜索范围
最近浏览过的 产品
比较和参考以前查看的项目
Image
最佳