  • Catalog Description:MS116-1.0 Manual Motor Starter 0.63 ... 1.0 A
  • Long Description:The MS116-1.0 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 1.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.
  • Unit of Measurement : PCS

Technical

  • Rated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 50 kA
  • (400 V AC) 50 kA
  • (440 V AC) 50 kA
  • (500 V AC) 30 kA
  • (690 V AC) 30 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V AC) 100 kA
  • (400 V AC) 100 kA
  • (440 V AC) 100 kA
  • (500 V AC) 100 kA
  • (690 V AC) 100 kA
  • Rated Instantaneous Short-Circuit Current Setting (Ii):12.5 A
  • Setting Range:0.63 ... 1.0 A
  • Rated Operational Power AC-3 (Pe):(400 V) Three Phase 0.25 kW
  • Rated Operational Power AC-3e (Pe):(400 V) Three Phase 0.25 kW
  • Rated Operational Voltage:Main Circuit 690 V AC
  • Rated Operational Current (Ie):1 A
  • Rated Operational Current AC-3 (Ie):1 A
  • Rated Operational Current AC-3e (Ie):1 A
  • Rated Frequency (f):Main Circuit 50 Hz
  • Main Circuit 60 Hz
  • Rated Impulse Withstand Voltage (Uimp):Main Circuit 6 kV
  • Rated Insulation Voltage (Ui):690 V
  • Power Loss:at Rated Operating Conditions per Pole 0.6 ... 1.6 W
  • Number of Poles:3
  • Conventional Free-air Thermal Current (Ith):Main Circuit 1 A
  • Degree of Protection:Housing IP20
  • Main Circuit Terminals IP10
  • Pollution Degree:3
  • Electrical Durability:100000 cycle
  • Mechanical Durability:100000 cycle
  • Terminal Type:Screw Terminals
  • Connecting Capacity Main Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible 1/2x 0.75 ... 2.5 mm²
  • Rigid 1/2x 1 ... 4 mm²
  • Tightening Torque:Main Circuit 0.8 ... 1.2 N·m
  • Wire Stripping Length:Main Circuit 9 mm
  • Recommended Screw Driver:Pozidriv 2
  • Mounting Position:any
  • 1 ... 6
  • Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
  • TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Minimum Mounting Distance:Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
  • Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
  • Electrical Conductive Board, Vertical 75 mm
  • Other Device Same Type, Horizontal 0 mm
  • Other Device Same Type, Vertical 150 mm
  • Actuator Type:Rotary Handle
  • Contact Position Indication:ON / OFF
  • Standards:IEC/EN 60947-1
  • IEC/EN 60947-2
  • IEC/EN 60947-4-1
  • UL 60947-1
  • UL 60947-4-1
¥ 508.81
数量:
EA
Stock:
1 EA 库存
location
In Seller's Warehouse
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
来自 ABB 的 Motor Starter
寻找和比较同类产品
更多来自 Motor Starter
用更广泛的选择扩大您的搜索范围
最近浏览过的 产品
比较和参考以前查看的项目
Image
最佳