Shopping List
รายการช้อปปิ้ง
ดูหมวดหมู่ทั้งหมด
ดูหมวดหมู่ทั้งหมด
SGD - S$
Image
/
/
/
/
Schneider Electric LC1D80008E7 คอนแทค, Tesys Deca, 4P(2NO+2NC), AC-1, <=440V, 125A, 48V Ac 50/60Hz Coil, Screw Clamp Terminal
Schneider Electric LC1D80008E7 คอนแทค, Tesys Deca, 4P(2NO+2NC), AC-1, <=440V, 125A, 48V Ac 50/60Hz Coil, Screw Clamp Terminal
ยี่ห้อ:
SCHNEIDER ELECTRIC
โมเดล:
LC1D80008E7
Image
Image
เอกสารข้อมูลทางเทคนิค
Specifications
infotip-icon
View other Contactors dimensions or variations
Please select at least one specification below.
Device Short Name
LC1D
Range Of Product
TeSys Deca
Depth
140 mm
Pole Contact Composition
2 NO + 2 NC
Poles Description
4P
Contactor Application
Resistive load
Compatibility Code
LC1D
This spec is not available in the specification table.
Standards
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
8 kV conforming to IEC 60947
This spec is not available in the specification table.
Mounting Support
Plate Rail
This spec is not available in the specification table.
Connections - Terminals
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: connector 1 4…50 mm² - cable stiffness: flexible without cable end Power circuit: connector 2 4…25 mm² - cable stiffness: flexible without cable end Power circuit: connector 1 4…50 mm² - cable stiffness: flexible with cable end Power circuit: connector 2 4…16 mm² - cable stiffness: flexible with cable end Power circuit: connector 1 4…50 mm² - cable stiffness: solid without cable end Power circuit: connector 2 4…25 mm² - cable stiffness: solid without cable end
This spec is not available in the specification table.
Height
127 mm
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 front face conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Mechanical Durability
4 Mcycles
This spec is not available in the specification table.
Electrical Durability
0.8 Mcycles 125 A AC-1 at Ue <= 440 V
This spec is not available in the specification table.
Operating Altitude
0...3000 m
This spec is not available in the specification table.
Tightening Torque
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm Power circuit: 12 N.m - on connector hexagonal screw head 4 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
Power circuit: <= 690 V AC 25...400 Hz
This spec is not available in the specification table.
[Ie] Rated Operational Current
125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
48 V AC 50/60 Hz
This spec is not available in the specification table.
Hold-in power consumption in VA
26 VA 60 Hz cos phi 0.3 (at 20 °C)<br />26 VA 50 Hz cos phi 0.3 (at 20 °C)
This spec is not available in the specification table.
Heat dissipation
6…10 W at 50/60 Hz
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Utilisation Category
AC-1
This spec is not available in the specification table.
Protective Cover
Without
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
125 A (at 60 °C) for power circuit
This spec is not available in the specification table.
Irms Rated Making Capacity
1100 A at 440 V for power circuit conforming to IEC 60947
This spec is not available in the specification table.
Rated Breaking Capacity
1100 A at 440 V for power circuit conforming to IEC 60947
This spec is not available in the specification table.
[Icw] Rated Short-Time Withstand Current
640 A 40 °C - 10 s for power circuit 990 A 40 °C - 1 s for power circuit 135 A 40 °C - 10 min for power circuit 320 A 40 °C - 1 min for power circuit
This spec is not available in the specification table.
Associated Fuse Rating
200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit
This spec is not available in the specification table.
Average Impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
This spec is not available in the specification table.
Power Dissipation Per Pole
12.5 W AC-1
This spec is not available in the specification table.
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
This spec is not available in the specification table.
Control Circuit Type
AC at 50/60 Hz
This spec is not available in the specification table.
Coil Technology
Without built-in suppressor module
This spec is not available in the specification table.
Control Circuit Voltage Limits
0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz 0.3...0.6 Uc (-40…55 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz
This spec is not available in the specification table.
Operating Time
20...35 ms closing 6...20 ms opening
This spec is not available in the specification table.
Auxiliary Contact Composition
3600 cyc/h 60 °C
This spec is not available in the specification table.
Protective Treatment
TH conforming to IEC 60068-2-30
This spec is not available in the specification table.
Climatic Withstand
conforming to IACS E10 exposure to damp heat
This spec is not available in the specification table.
Permissible Ambient Air Temperature Around The Device
-40…60 °C 60…70 °C with derating
This spec is not available in the specification table.
Fire Resistance
850 °C conforming to IEC 60695-2-1
This spec is not available in the specification table.
Flame Retardance
V1 conforming to UL 94
This spec is not available in the specification table.
Mechanical Robustness
Vibrations contactor open (2 Gn, 5...300 Hz) Shocks contactor open (8 Gn for 11 ms) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms)
This spec is not available in the specification table.
รายละเอียดสินค้า

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contactors จาก SCHNEIDER ELECTRIC
แหล่งที่มาและเปรียบเทียบผลิตภัณฑ์ที่คล้ายคลึงกัน
เพิ่มเติมจาก Contactors
ขยายการค้นหาของคุณด้วยตัวเลือกที่กว้างขึ้น
ดูล่าสุด สินค้า
เปรียบเทียบและอ้างอิงรายการที่ดูก่อนหน้านี้
Image
สูงสุด