Safety Function: STO (Safe Torque Off), Integrated
Safety Level:
SIL 2 conforming to IEC 61800-5-2: 2007
SIL 2 conforming to IEC 61508-1: 2010
PL d/category 3 conforming to ISO 13849-1: 2008
SIL 2 conforming to ISO 13849-1: 2009/AC
SIL 2 conforming to IEC 60204-1: 2006
SIL 2 conforming to IEC 60204-1: 2009/A1
SIL 2 conforming to IEC 60204-1: 2010/AC
SIL 2 conforming to IEC 62061: 2012
Communication interface: EtherCAT, Integrated
Connector Type: RJ45 (CN4) for EtherCAT
Method of Access: Slave
Transmission Rate: 100 Mbit/s for EtherCAT
Physical Interface: RS485 for Modbus Serial Line Slave
Status LED: 1 LED (Red) DC Bus Energized, 1 LED (Multi-colour) N.RUN, 1 LED (Multi-colour) N.ERR, 2 LEDs (Green) Link (Link Status), 2 LEDs (Yellow) Activity
Signalling Function: Servo Status and Fault Codes, Five 7-Segment Display Units
Marking: CE, CULus
Type of Cooling: Fan
Operating Position: Vertical
Product Compatibility: Servo Motor BCH2 (130 mm, 1 Motor Stacks) at 500 W, Servo Motor (80 mm, 2 Motor Stacks) at 750 W, Servo Motor (130 mm, 1 Motor Stacks) at 600 W
Width: 55 mm
Height: 150 mm
Depth: 146 mm
Net Weight: 1 kg
Output current 3s peak 2: 13.5 A at 220 V
Output current 3s peak 3: 13.5 A at 220 V
Electromagnetic Compatibility: Conducted Emission - Test Level: Level 3 Category C3 Conforming to IEC 61800-3
Standards: IEC 61800-5-1
Product Certifications: CSA, CE, CULus
IP Degree of Protection: IP20
Vibration Resistance: 3M4 Amplitude = 3 mm (f = 9…200 Hz) Conforming to IEC 60721-3-3
Shock Resistance: 10 gn, Type I Conforming to IEC 60721-3-3