Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric XESD1291 Double Contact Block, Harmony Xac, Spring Return, 2 Speed, Snap Action, 2NO+1 Co
Schneider Electric XESD1291 Double Contact Block, Harmony Xac, Spring Return, 2 Speed, Snap Action, 2NO+1 Co
Image
Image
Specifications
infotip-icon
View other Contact Block dimensions or variations
Please select at least one specification below.
Contacts type and composition
2 NO + 1 C/O
Product Or Component Type
Contact block
Range Of Product
Harmony XAC
Standards
IEC 60947-3 CSA C22.2 No 14 EN 60947-3
[Ui] Rated Insulation Voltage
600 V conforming to CSA
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-1
Contact Operation
Snap action Staggered
Connections - Terminals
Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end
This spec is not available in the specification table.
Ambient Air Temperature For Operation
-25…70 °C
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…70 °C
This spec is not available in the specification table.
Short-Circuit Protection
10 A fuse protection by cartridge fuse type aM
This spec is not available in the specification table.
Mechanical Durability
500000 cycles 1000000 cycles
This spec is not available in the specification table.
Electrical Durability
300000 cycles AC-3, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A 300000 cycles AC-3, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A 300000 cycles AC-4, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A 300000 cycles AC-4, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A 500000 cycles AC-3, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A 500000 cycles AC-4, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A 800000 cycles AC-3, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A 800000 cycles AC-4, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
This spec is not available in the specification table.
Shock Resistance
100 gn conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
This spec is not available in the specification table.
Terminals Description Iso N°1
(13-14)NO B (23-24)NO (51-52-54)OC
This spec is not available in the specification table.
Contact Block Type
Double
This spec is not available in the specification table.
Operating Force
17 N
This spec is not available in the specification table.
Mounting Of Block
Front mounting
This spec is not available in the specification table.
Electrical Shock Protection Class
Class II conforming to IEC 61140
This spec is not available in the specification table.
Poles Description
2-pole
This spec is not available in the specification table.
Terminal Identifier
(13-14)NO (11-12)NC
This spec is not available in the specification table.
Product Compatibility
XACB
This spec is not available in the specification table.
Rated Operational Power In W
2200 W AC-3 at 240 V conforming to IEC 60947-3 appendix A 2200 W AC-4 at 400 V conforming to IEC 60947-3 appendix A
This spec is not available in the specification table.
Electrical Circuit Type
Power circuit
This spec is not available in the specification table.
Type Of Operator
2 spring return
This spec is not available in the specification table.
Component Name
XESD
This spec is not available in the specification table.
Contact Block Application
2-speed
This spec is not available in the specification table.
[Ithe] Conventional Enclosed Thermal Current
12 A
This spec is not available in the specification table.
Mechanical Interlocking
With mechanical interlocking
This spec is not available in the specification table.
Horizontal Fixing Centres
40 mm
This spec is not available in the specification table.
Terminals Description Iso N°2
B (43-44)NO (61-62-64)OC (33-34)NO
This spec is not available in the specification table.
Product Description
S$ 251.90
(exc. GST)
S$ 274.57
(inc. GST)
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Contact Block
41 Items
contact-block-img
Contacts type and composition
1 NC + 1 NO, 2 NC, 1 C/O + 1 NO, 2 NO + 1 C/O, 1 NC + 2 NO
Range Of Product
Harmony 9001K Harmony 9001SK, Harmony XB6, Harmony XAC, Harmony XAL Harmony XAPS, Harmony XAPS Harmony XAL
Standards
IEC 60947-3 CSA C22.2 No 14 EN 60947-3, EN/IEC 60947-5-1 UL 508 EN/IEC 60204-32 CSA C22.2 No 14, CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508, IEC 60947-5-1 CSA C22.2 No 14 IEC 60947-1 UL 508 IEC 60947-5-5 JIS C8201-5-1 IEC 60947-5-4 JIS C8201-1, IEC 60947-5-5 IEC 60947-5-4 UL 508 JIS C8201-5-1 IEC 60947-1 CSA C22.2 No 14 IEC 60947-5-1 JIS C8201-1
[Ui] Rated Insulation Voltage
600 V (pollution degree 3) conforming to IEC 60947-1, 250 V (pollution degree 3) conforming to IEC 60947-1, 250 V (pollution degree 3) conforming to EN/IEC 60947-1, 500 V (pollution degree 3) conforming to IEC 60947-1, 600 V conforming to CSA
[Uimp] Rated Impulse Withstand Voltage
4 kV conforming to IEC 60947-1, 6 kV conforming to EN 60947-1, 6 kV conforming to IEC 60947-1, 2.5 kV conforming to IEC 60947-1, 4 kV conforming to EN/IEC 60947-1
[Ie] Rated Operational Current
3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1, 2 A at 230 V, AC-15, A600 conforming to IEC 60947-5-1 0.2 A at 110 V, DC-13, Q600 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A600-Q600 conforming to NEMA 0.55 A at 125 V, DC-13, A600-Q600 conforming to NEMA, 3 A at 120 V, AC-15, B300 1.5 A at 240 V, AC-15, B300 0.1 A at 250 V, DC-13, R300 0.22 A at 125 V, DC-13, R300
Contact Operation
Positive opening, Standard, Staggered Snap action, Snap action Staggered, Slow-break Staggered
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contact Block from SCHNEIDER ELECTRIC
Source & compare similar products
More from Contact Block
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top