Schneider Electric XB5AS8444 Emergency Stop Switching Off, Harmony XB5, Plastic, Red Mushroom 40mm, 22mm, Trigger Latching Turn to Release, 2NC
Schneider Electric XB5AS8444 Emergency Stop Switching Off, Harmony XB5, Plastic, Red Mushroom 40mm, 22mm, Trigger Latching Turn to Release, 2NC
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Emergency Stop Push Buttons dimensions or variations
Please select at least one specification below.
Range Of Product
Harmony XB5
Standards
IEC 60204-1 IEC 60947-5-1 CSA C22.2 No 14 ISO 13850 IEC 60947-5-5 IEC 60364-5-53 IEC 60947-5-4 JIS C8201-5-1 UL 508 IEC 60947-1 JIS C8201-1
[Ui] Rated Insulation Voltage
600 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-1
Connections - Terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
Ip Degree Of Protection
IP66 conforming to IEC 60529 IP67 IP69 IP69K
Mechanical Durability
300000 cycles
Product Certifications
GL CSA DNV UL listed BV LROS (Lloyds register of shipping)
Mounting Diameter
22 mm
Shape Of Signaling Unit Head
Round
Terminals Description Iso N°1
(11-12)NC
Device Short Name
XB5
This spec is not available in the specification table.
Product Or Component Type
Emergency switching off push-button
This spec is not available in the specification table.
Overvoltage Category
Class II conforming to IEC 60536
This spec is not available in the specification table.
Ambient Air Temperature For Operation
-40…70 °C
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…70 °C
This spec is not available in the specification table.
Electrical Durability
1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
This spec is not available in the specification table.
Contacts Material
Silver alloy (Ag/Ni)
This spec is not available in the specification table.
[Ie] Rated Operational Current
3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
This spec is not available in the specification table.
Ik Degree Of Protection
IK03 conforming to IEC 50102
This spec is not available in the specification table.
Shock Resistance
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
This spec is not available in the specification table.
Protective Treatment
TH
This spec is not available in the specification table.
Nema Degree Of Protection
NEMA 13 NEMA 4X
This spec is not available in the specification table.
Type Of Operator
trigger action and mechanical latching
This spec is not available in the specification table.
Operator Profile
Red mushroom Ø 40 mm, unmarked
This spec is not available in the specification table.
Contact Operation
Slow-break
This spec is not available in the specification table.
Positive Opening
With conforming to IEC 60947-5-1 appendix K
This spec is not available in the specification table.
Short-Circuit Protection
10 A cartridge fuse type gG conforming to IEC 60947-5-1
This spec is not available in the specification table.
Electrical Reliability
Λ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4 Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4
This spec is not available in the specification table.
Bezel Material
Dark grey plastic
This spec is not available in the specification table.
Operating Travel
1.5 mm (NC changing electrical state) 4.3 mm (total travel)
This spec is not available in the specification table.
Reset
Turn to release
This spec is not available in the specification table.
Tightening Torque
0.8…1.2 N.m conforming to IEC 60947-1
This spec is not available in the specification table.
Device Presentation
Complete product
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
10 A conforming to IEC 60947-5-1
This spec is not available in the specification table.
Resistance To High Pressure Washer
7000000 Pa at 55 °C, distance : 0.1 m
This spec is not available in the specification table.
Shape Of Screw Head
Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver
This spec is not available in the specification table.
Fixing Collar Material
Plastic
This spec is not available in the specification table.
Head Type
Standard
This spec is not available in the specification table.
Contacts Usage
Standard contacts
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Emergency Stop Push Buttons from SCHNEIDER ELECTRIC
Source & compare similar products
More from Emergency Stop Push Buttons
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top