Product Or Component Type
Logic controller
Range Of Product
Modicon M221
Standards
IEC 61131-2 UL 508 CAN/CSA C22.2 No. 213 IACS E10 ANSI/ISA 12-12-01
Ip Degree Of Protection
IP20 with protective cover in place
Relative Humidity
10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage)
Ambient Air Temperature For Operation
-10…55 °C (horizontal installation) -10…35 °C (vertical installation)
Ambient Air Temperature For Storage
-25…70 °C
Operating Altitude
0...2000 m
Product Certifications
RCM EAC ABS LR cULus DNV-GL CE UKCA cULus HazLoc
[Us] Rated Supply Voltage
24 V DC
Local Signalling
1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED per channel (green) for I/O state 1 LED (green) for SL Ethernet network activity (green) for ACT Ethernet network link (yellow) for Link (Link Status)
This spec is not available in the specification table.
Mounting Support
Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit
This spec is not available in the specification table.
Pollution Degree
<= 2
This spec is not available in the specification table.
Discrete Input Number
24, discrete input 4 fast input conforming to IEC 61131-2 Type 1
This spec is not available in the specification table.
Discrete Input Voltage
24 V
This spec is not available in the specification table.
Discrete Input Current
7 mA for discrete input 5 mA for fast input
This spec is not available in the specification table.
Input Impedance
3.4 kOhm for discrete input 100 kOhm for analog input 4.9 kOhm for fast input
This spec is not available in the specification table.
Realtime Clock
With
This spec is not available in the specification table.
Discrete Input Logic
Sink or source (positive/negative)
This spec is not available in the specification table.
Analogue Input Number
2 at 0...10 V
This spec is not available in the specification table.
Discrete Output Number
16 transistor 2 fast output
This spec is not available in the specification table.
Discrete Output Current
0.5 A
This spec is not available in the specification table.
Insulation
Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Non-insulated between inputs Between output and internal logic at 500 V AC Non-insulated between analogue input and internal logic Non-insulated between analogue inputs
This spec is not available in the specification table.
Communication Port Protocol
USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network Ethernet
This spec is not available in the specification table.
Mechanical Durability
20000000 cycles for transistor output
This spec is not available in the specification table.
Marking
CE
This spec is not available in the specification table.
Environmental Characteristic
Ordinary and hazardous location
This spec is not available in the specification table.
Shock Resistance
147 m/s² for 11 ms
This spec is not available in the specification table.
Vibration Resistance
3.5 mm at 5…8.4 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 1 gn at 8.4…150 Hz on symmetrical rail 1 gn at 8.4…150 Hz on panel mounting
This spec is not available in the specification table.
Resistance To Electrostatic Discharge
8 kV in air conforming to IEC 61000-4-2 4 kV on contact conforming to IEC 61000-4-2
This spec is not available in the specification table.
Resistance To Fast Transients
2 kV (power lines) conforming to IEC 61000-4-4 2 kV (relay output) conforming to IEC 61000-4-4 1 kV (I/O) conforming to IEC 61000-4-4 1 kV (Ethernet line) conforming to IEC 61000-4-4 1 kV (serial link) conforming to IEC 61000-4-4
This spec is not available in the specification table.
Immunity To Microbreaks
10 ms
This spec is not available in the specification table.
Supply Voltage Limits
20.4…28.8 V
This spec is not available in the specification table.
Maximum Voltage Drop
<1 V
This spec is not available in the specification table.
Protection Type
Overload and short-circuit protection at 1 A
This spec is not available in the specification table.
Response Time
35 µs turn-off, I2...I5 terminal(s) for input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input 35 µs turn-on, other terminals terminal(s) for input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input 100 µs turn-off, other terminals terminal(s) for input 5 µs turn-on, turn-off, Q0...Q1 terminal(s) for output 50 µs turn-on, turn-off, Q2...Q3 terminal(s) for output 300 µs turn-on, turn-off, other terminals terminal(s) for output
This spec is not available in the specification table.
Maximum Power Consumption In W
17 W at 24 V (with max number of I/O expansion module) 4.9 W at 24 V (without I/O expansion module)
This spec is not available in the specification table.
Communication Service
Modbus TCP slave device Ethernet/IP adapter Modbus TCP server Modbus TCP client DHCP client
This spec is not available in the specification table.
Backup Time
1 year at 25 °C (by interruption of power supply)
This spec is not available in the specification table.
Clock Drift
<= 30 s/month at 25 °C
This spec is not available in the specification table.
Voltage State 1 Guaranteed
>= 15 V for input
This spec is not available in the specification table.
Voltage State 0 Guaranteed
<= 5 V for input
This spec is not available in the specification table.
Integrated Connection Type
USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface Ethernet with RJ45 connector
This spec is not available in the specification table.
Surge Withstand
2 kV power lines (AC) common mode conforming to IEC 61000-4-5 2 kV relay output common mode conforming to IEC 61000-4-5 1 kV I/O common mode conforming to IEC 61000-4-5 1 kV shielded cable common mode conforming to IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5 1 kV power lines (AC) differential mode conforming to IEC 61000-4-5 1 kV relay output differential mode conforming to IEC 61000-4-5 0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5
This spec is not available in the specification table.
Resistance To Electromagnetic Fields
10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3 1 V/m 2...2.7 GHz conforming to IEC 61000-4-3
This spec is not available in the specification table.
Electromagnetic Emission
Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to IEC 55011 Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to IEC 55011 Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to IEC 55011 Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to IEC 55011 Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to IEC 55011 Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to IEC 55011 Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to IEC 55011
This spec is not available in the specification table.
Inrush Current
35 A
This spec is not available in the specification table.
Electrical Connection
removable screw terminal block for inputs removable screw terminal block for outputs terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputs Mini B USB 2.0 connector for a programming terminal
This spec is not available in the specification table.
Discrete Output Type
Transistor
This spec is not available in the specification table.
Reset Time
1 s automatic reset
This spec is not available in the specification table.
Maximum Cable Distance Between Devices
Shielded cable: <10 m for fast input Unshielded cable: <30 m for output Unshielded cable: <30 m for digital input Unshielded cable: <1 m for analog input Shielded cable: <3 m for fast output
This spec is not available in the specification table.
Function Available
PWM PLS Frequency generator
This spec is not available in the specification table.
Port Ethernet
10BASE-T/100BASE-TX 1 port with 100 m copper cable
This spec is not available in the specification table.
Discrete I/O Number
40
This spec is not available in the specification table.
Discrete Input Voltage Type
DC
This spec is not available in the specification table.
Resistance To Magnetic Fields
30 A/m 50/60 Hz conforming to IEC 61000-4-8
This spec is not available in the specification table.
Resistance To Conducted Disturbances
10 V 0.15...80 MHz conforming to IEC 61000-4-6 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
This spec is not available in the specification table.
Storage Altitude
0…3000 m
This spec is not available in the specification table.
Discrete Output Voltage
24 V DC
This spec is not available in the specification table.
Maximum Number Of I/O Expansion Module
7 (local I/O-Architecture) 14 (remote I/O-Architecture)
This spec is not available in the specification table.
Power Supply Output Current
0.52 A 5 V for expansion bus 0.3 A 24 V for expansion bus
This spec is not available in the specification table.
Analogue Input Resolution
10 bits
This spec is not available in the specification table.
Lsb Value
10 mV
This spec is not available in the specification table.
Conversion Time
1 ms per channel + 1 controller cycle time for analogue input analog input
This spec is not available in the specification table.
Permitted Overload On Inputs
+/- 30 V DC for 5 min (maximum) for analog input +/- 13 V DC (permanent) for analog input
This spec is not available in the specification table.
Configurable Filtering Time
0 ms for input 3 ms for input 12 ms for input
This spec is not available in the specification table.
Discrete Output Logic
Positive logic (source)
This spec is not available in the specification table.
Maximum Current Per Output Common
4 A
This spec is not available in the specification table.
Output Frequency
100 kHz for fast output (PWM/PLS mode) at Q0...Q1 5 kHz for output at Q2...Q3 0.1 kHz for output at Q4...Q15
This spec is not available in the specification table.
Absolute Accuracy Error
+/- 1 % of full scale for analog input
This spec is not available in the specification table.
Maximum Leakage Current
0.1 mA for transistor output
This spec is not available in the specification table.
Maximum Tungsten Load
<12 W for output and fast output
This spec is not available in the specification table.
Memory Capacity
256 kB for user application and data RAM with 10000 instructions 256 kB for internal variables RAM
This spec is not available in the specification table.
Data Backed Up
256 kB built-in flash memory for backup of application and data
This spec is not available in the specification table.
Data Storage Equipment
2 GB SD card (optional)
This spec is not available in the specification table.
Battery Type
BR2032 or CR2032X lithium non-rechargeable
This spec is not available in the specification table.
Execution Time For 1 Kinstruction
0.3 ms for event and periodic task
This spec is not available in the specification table.
Execution Time Per Instruction
0.2 µs Boolean
This spec is not available in the specification table.
Exct Time For Event Task
60 µs response time
This spec is not available in the specification table.
Maximum Size Of Object Areas
512 %KW constant words 255 %TM timers 255 %C counters 8000 %MW memory words 512 %M memory bits
This spec is not available in the specification table.
Regulation Loop
Adjustable PID regulator up to 14 simultaneous loops
This spec is not available in the specification table.
Positioning Functions
Position PTO 2 axe(s)pulse/direction mode (100 kHz) Position PTO 1 axe(s)CW/CCW mode (100 kHz)
This spec is not available in the specification table.
Counting Input Number
4 fast input (HSC mode) at 100 kHz 32 bits
This spec is not available in the specification table.
Counter Function
A/B Pulse/direction Single phase
This spec is not available in the specification table.
Supply
(serial)serial link supply: 5 V, <200 mA
This spec is not available in the specification table.
Transmission Rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for USB
This spec is not available in the specification table.
Product Description
S$ 1,085.20
(exc. GST)
S$ 1,182.87
(inc. GST)
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Programmable Logic Controllers
45 Items
programmable-logic-controllers-img
Product Or Component Type
Discrete I/O extension module, Modular smart relay, Compact smart relay, Compact discovery packs, Programmable controllers
Range Of Product
Modicon M251, Easy Modicon M200, Modicon M221, Modicon M171/M172, SpaceLogic KNX
Standards
IEC 61131-2 UL 508 CAN/CSA C22.2 No. 213 IACS E10 ANSI/ISA 12-12-01, CAN/CSA-E60730-1<br />CSA E60730-2-9<br />EN 60068-2-27<br />EN 60068-2-6 Fc<br />EN 60730-1<br />EN 60730-2-9<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-2<br />IEC 61000-4-3<br />IEC 61000-4-4<br />IEC 61000-4-5<br />IEC 61000-4-6<br />IEC 61000-4-11<br />UL94 (material V0), IEC 61000-4-5<br />IEC 61000-4-3<br />IEC 61000-4-2<br />EN 60068-2-27<br />EN 60730-1<br />EN 60068-2-6 Fc<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-4<br />CAN/CSA-E60730-1<br />IEC 61000-4-11<br />IEC 61000-4-6<br />CSA E60730-2-9<br />EN 60730-2-9<br />UL94 (material V0), CSA, UL, CSA Certified, UL Listed
Ambient Air Temperature For Operation
-10…35 °C (vertical installation) -10…55 °C (horizontal installation), -10…50 °C (vertical installation) -10…55 °C (horizontal installation), -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2, -20…65 °C conforming to UL 60730-1<br />-20…60 °C horizontal conforming to UL 60730-1, -20…60 °C conforming to UL 60730-1<br />-20…65 °C with derating conforming to UL 60730-1
Product Certifications
GL C-Tick CSA UL GOST, GOST CSA UL C-Tick GL, DNV-GL EAC ABS cULus LR RCM CE UKCA cULus HazLoc, EAC<br />CE<br />cURus<br />CSA<br />RCM, CSA<br />EAC<br />RCM<br />CE<br />cURus
[Us] Rated Supply Voltage
24 V, 100...240 V AC, 24 V +/- 10 % AC<br />20...38 V DC, 24 V dc, 4.75 → 5.25 V
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Programmable Logic Controllers from SCHNEIDER ELECTRIC
Source & compare similar products
More from Programmable Logic Controllers
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top