Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric RXM2LB1B7 Miniature, Harmony Electromechanical Relays, 5A, 2CO, Without Led, 24V Ac
Schneider Electric RXM2LB1B7 Miniature, Harmony Electromechanical Relays, 5A, 2CO, Without Led, 24V Ac
Image
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Power Relay dimensions or variations
Please select at least one specification below.
Contact Material
Silver alloy (Ag/Ni)
Standards Met
CE IEC 61810-1 (iss. 2)
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
55°C
[Ui] Rated Insulation Voltage
250 V conforming to IEC
IP Degree of Protection
IP40 conforming to IEC 60529
[Ie] Rated Operational Current
5 A (AC-1/DC-1) NO conforming to IEC 2.5 A (AC-1/DC-1) NC conforming to IEC 1 A at 28 V (DC-13) NO
Operating Rate
<= 1200 cycles/hour under load <= 18000 cycles/hour no-load
Control Type
Without push-button
This spec is not available in the specification table.
Device Short Name
RXM
This spec is not available in the specification table.
Product or Component Type
Plug-in relay
This spec is not available in the specification table.
Range of Product
Harmony Electromechanical Relays
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
4 kV during 1.2/50 µs conforming to IEC 61810-7
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Mechanical Durability
10000000 cycles
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Electrical Durability
100000 cycles for resistive load 50000 cycles, 1 A at 28 V, DC-13 NO
This spec is not available in the specification table.
[Uc] control circuit voltage
24 V AC 50/60 Hz
This spec is not available in the specification table.
Operating time
20 ms between coil de-energisation and making of the Off-delay contact 20 ms between coil energisation and making of the On-delay contact
This spec is not available in the specification table.
Minimum switching voltage
5 V
This spec is not available in the specification table.
Minimum Switching Current
5 mA
This spec is not available in the specification table.
Contacts type and composition
2 C/O
This spec is not available in the specification table.
Operating Position
Any position
This spec is not available in the specification table.
Shock Resistance
30 gn for not operating conforming to IEC 60068-2-27 10 gn for in operation conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
3 gn, amplitude = +/- 1 mm (f = 10…50 Hz)operating conforming to IEC 60068-2-6 6 gn, amplitude = +/- 1 mm (f = 10…50 Hz)not operating conforming to IEC 60068-2-6
This spec is not available in the specification table.
Dielectric Strength
2000 V AC between coil and contact with basic insulation 2000 V AC between poles with basic insulation 1000 V AC between contacts with micro disconnection
This spec is not available in the specification table.
CAD Overall Width
21 mm
This spec is not available in the specification table.
CAD Overall Height
27 mm
This spec is not available in the specification table.
CAD Overall Depth
46 mm
This spec is not available in the specification table.
Contact operation
Standard
This spec is not available in the specification table.
[Ithe] conventional enclosed thermal current
5 A at -40…55 °C
This spec is not available in the specification table.
Series Name
Miniature
This spec is not available in the specification table.
Status LED
Without
This spec is not available in the specification table.
Utilisation coefficient
20 %
This spec is not available in the specification table.
Maximum switching voltage
250 V AC 28 V DC
This spec is not available in the specification table.
Maximum switching capacity
1250 VA AC 140 W DC
This spec is not available in the specification table.
Minimum switching capacity
170 mW
This spec is not available in the specification table.
Drop-out voltage threshold
>= 0.15 Uc AC
This spec is not available in the specification table.
Rated operational voltage limits
19.2...26.4 V AC
This spec is not available in the specification table.
Protection category
RT I
This spec is not available in the specification table.
Test levels
Level A group mounting
This spec is not available in the specification table.
Safety reliability data
B10d = 100000
This spec is not available in the specification table.
Load current
5 A at 250 V AC 5 A at 28 V DC
This spec is not available in the specification table.
average coil consumption in VA
1.2 AC
This spec is not available in the specification table.
Coil interference suppression
Without
This spec is not available in the specification table.
Average resistance
180 Ohm at 23 °C +/- 10 %
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Power Relay from SCHNEIDER ELECTRIC
Source & compare similar products
More from Power Relay
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top