Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric RM35JA32MR Current Control Relay, Harmony Control Relays, 5A, 2CO, 0.15…15A, 24…240V Ac Dc
Schneider Electric RM35JA32MR Current Control Relay, Harmony Control Relays, 5A, 2CO, 0.15…15A, 24…240V Ac Dc
Image
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Control Relays dimensions or variations
Please select at least one specification below.
Utilisation Category
AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1
Standards
IEC 60255-1
Mounting Support
35 mm DIN rail conforming to IEC 60715
Ip Degree Of Protection
IP20 (terminals) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 IP30 (housing) conforming to IEC 60529
Ambient Air Temperature For Operation
-20…50 °C at 60 Hz -20…60 °C at 50 Hz
Mechanical Durability
10000000 cycles
Ambient Air Temperature For Storage
-40…70 °C
Minimum Switching Current
10 mA at 5 V DC
Insulation Resistance
> 100 MOhm at 500 V DC conforming to IEC 60255-27
Product Certifications
CE GL CCC EAC RCM UL CSA
Connections - Terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
This spec is not available in the specification table.
Tightening Torque
0.6…1 N.m conforming to IEC 60947-1
This spec is not available in the specification table.
Immunity To Microbreaks
50 ms
This spec is not available in the specification table.
Local Signalling
LED (yellow) for relay ON LED (green) for power ON
This spec is not available in the specification table.
Control Type
With test button
This spec is not available in the specification table.
Range Of Product
Harmony Control Relays
This spec is not available in the specification table.
Housing Material
Self-extinguishing plastic
This spec is not available in the specification table.
Overvoltage Category
III conforming to IEC 60664-1 III conforming to UL 508
This spec is not available in the specification table.
Pollution Degree
3 conforming to IEC 60664-1 3 conforming to UL 508
This spec is not available in the specification table.
Relative Humidity
93…97 % at 25…55 °C conforming to IEC 60068-2-30
This spec is not available in the specification table.
Electrical Durability
100000 cycles
This spec is not available in the specification table.
Contacts Material
Cadmium free
This spec is not available in the specification table.
Maximum Power Consumption In Va
3.5 VA
This spec is not available in the specification table.
Electromagnetic Compatibility
Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 Immunity for industrial environments conforming to IEC 61000-6-2 Emission standard for industrial environments conforming to IEC 61000-6-4 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22 Emission standard for residential, commercial and light-industrial environments (except radiated emission) conforming to IEC 61000-6-3
This spec is not available in the specification table.
Contacts Type And Composition
2 C/O
This spec is not available in the specification table.
Shock Resistance
15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
This spec is not available in the specification table.
Supply Voltage Limits
20.4…264 V AC/DC
This spec is not available in the specification table.
Response Time
<= 500 ms (on crossing the threshold)
This spec is not available in the specification table.
Maximum Power Consumption In W
1.5 W DC
This spec is not available in the specification table.
Maximum Switching Current
8 A AC
This spec is not available in the specification table.
Maximum Switching Voltage
250 V AC
This spec is not available in the specification table.
Safety Reliability Data
MTTFd = 296.8 years B10d = 270000
This spec is not available in the specification table.
Nominal Output Current
8 A
This spec is not available in the specification table.
Repeat Accuracy
+/- 0.5 % for input and measurement circuit +/- 2 % for time delay
This spec is not available in the specification table.
Setting Accuracy Of Time Delay
10 P
This spec is not available in the specification table.
Switching Capacity In Va
2000 VA
This spec is not available in the specification table.
Relay Type
Current control relay
This spec is not available in the specification table.
Relay Name
RM35JA
This spec is not available in the specification table.
Relay Monitored Parameters
Overcurrent or undercurrent in window mode Overcurrent or undercurrent detection
This spec is not available in the specification table.
Time Delay
Adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault
This spec is not available in the specification table.
Measurement Range
150 mA...15 A AC/DC
This spec is not available in the specification table.
Reset Time
1500 ms at maximum voltage
This spec is not available in the specification table.
Resistance Across Terminals
0.005 Ohm at E3-M terminals 0.015 Ohm at E2-M terminals 0.05 Ohm at E1-M terminals
This spec is not available in the specification table.
Output Contacts
2 C/O
This spec is not available in the specification table.
Hysteresis
5…50 % adjustable of threshold setting 3 % fixed of full scale for window mode
This spec is not available in the specification table.
Delay At Power Up
0.3 s
This spec is not available in the specification table.
Maximum Measuring Cycle
100 ms measurement cycle as true rms value
This spec is not available in the specification table.
Measurement Error
< 1 % over the whole range with voltage variation 0.05 %/°C with temperature variation
This spec is not available in the specification table.
Insulation
Between supply and measurement
This spec is not available in the specification table.
[Un] Rated Nominal Voltage
24...240 V AC/DC 50/60 Hz
This spec is not available in the specification table.
Dielectric Test Voltage
2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
This spec is not available in the specification table.
Operating Voltage Tolerance
- 15 % + 10 % Un
This spec is not available in the specification table.
Internal Input Resistance
0.015 Ohm 0.005 Ohm 0.05 Ohm
This spec is not available in the specification table.
Setting Accuracy Of The Switching Threshold
+/- 10 % of the full scale
This spec is not available in the specification table.
Switching Threshold Drift
<= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range
This spec is not available in the specification table.
Time Delay Drift
<= 0.05 % per degree centigrade depending permissible ambient air temperature <= 1 % within the supply voltage range
This spec is not available in the specification table.
Threshold Setting
10...100 %
This spec is not available in the specification table.
Product Description
S$ 177.70
(exc. GST)
S$ 193.69
(inc. GST)
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Control Relays
37 Items
control-relays-img
Utilisation Category
DC-13 AC-15 AC-14, AC-14 AC-15 DC-13, AC-14 DC-13 AC-15, AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1, AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1
Standards
EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1, IEC 61984, IEC 60255-6, IEC 60255-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947 690 V conforming to VDE 0110 group C 690 V conforming to BS 5424 690 V conforming to UL 508 690 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947 750 V conforming to VDE 0110 group C 690 V conforming to BS 5424 600 V conforming to CSA C22.2 No 14, 400 V, 250 V conforming to IEC 60664-1, 250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1
Ip Degree Of Protection
IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529, IP20 conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 IP30 (housing) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Ambient Air Temperature For Operation
-40…60 °C 60…70 °C with derating, -20…60 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz AC/DC, -25…85 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz
Mechanical Durability
20 Mcycles, 30 Mcycles, 10 Mcycles, 10000000 cycles, 30000000 cycles
Ambient Air Temperature For Storage
-50…80 °C, -60…80 °C, -50…70 °C, -40…85 °C, -40…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Control Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Control Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top