Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric LV429682 Tmd - Circuit Breaker Compact NSX100H
Schneider Electric LV429682 Tmd - Circuit Breaker Compact NSX100H
Image
Image
Specifications
infotip-icon
View other Molded Case Circuit Breakers - MCCBs dimensions or variations
Please select at least one specification below.
Rated Current
63A
Poles
4P
Standards and Certifications
EN/IEC 60947-2, UL 508
This spec is not available in the specification table.
Breaking Capacity
"10 kA at 600 V AC 50/60 Hz conforming to UL 508, 85 kA at 240 V AC 50/60 Hz conforming to UL 508, 65 kA at 480 V AC 50/60 Hz conforming to UL 508, 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2"
This spec is not available in the specification table.
Rated Voltage
690 V AC 50/60 Hz
This spec is not available in the specification table.
Trip Curve
TMD
This spec is not available in the specification table.
Mounting Type
Fixed
This spec is not available in the specification table.
Product Description

SCHNEIDER ELECTRIC Circuit Breaker Compact NSX100H - Tmd - 63 a - 4 Poles 3d LV429682

Main features

  • Range : ComPact
  • Product name : ComPact NSX
  • Range of product : ComPact NSX100...250
  • Device short name : NSX100H
  • Product or component type : Circuit breaker
  • Device application : Distribution
  • Poles description : 4P
  • Protected poles description : 3t
  • Neutral position : Left
  • [In] rated current : 63 A at 40 °C
  • [Ue] rated operational voltage : 690 V AC 50/60 Hz
  • Network type : AC
  • Network frequency : 50/60 Hz
  • Suitability for isolation : Yes conforming to EN/IEC 60947-2
  • Utilisation category : Category A
  • Breaking capacity : 10 kA at 600 V AC 50/60 Hz conforming to UL 50885 kA at 240 V AC 50/60 Hz conforming to UL 50865 kA at 480 V AC 50/60 Hz conforming to UL 50810 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-265 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  • Breaking capacity code : H 70 kA 415 V AC
  • Trip unit name : TM-D
  • Trip unit technology : Thermal-magnetic
  • Trip unit protection functions : LI
  • Control type : Toggle
  • Mounting mode : Fixed
S$ 668.30
(exc. GST)
S$ 728.45
(inc. GST)
Image
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item