This spec is not available in the specification table.
Rated Voltage
690 V AC 50/60 Hz
This spec is not available in the specification table.
Dimensions
105 mm x 161 mm x 86 mm
This spec is not available in the specification table.
Weight
2.05 kg
This spec is not available in the specification table.
Breaking Capacity
"10 kA at 600 V AC 50/60 Hz conforming to UL 508, 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 65 kA at 480 V AC 50/60 Hz conforming to UL 508, 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA at 240 V AC 50/60 Hz conforming to UL 508"
This spec is not available in the specification table.
Standards and Certifications
EN/IEC 60947, CCC, EAC, Marine
This spec is not available in the specification table.
Trip Curve
TMD
This spec is not available in the specification table.
Mounting Type
Backplate
This spec is not available in the specification table.
Product Description
SCHNEIDER ELECTRIC Circuit Breaker Compact NSX100H - Tmd - 80 a - 3 Poles 3d LV429671
MAIN SPECIFICATIONS
Breaking Capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 480 V AC 50/60 Hz conforming to UL 508
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 240 V AC 50/60 Hz conforming to UL 508
Breaking Capacity Code H 70 kA 415 V AC
Contacts Type And Composition 80 A at 40 °C
Control Type toggle
Product Or Component Type circuit breaker
Range Of Product ComPact NSX100...250
Trip Unit Name TM-D
[Ie] Rated Operational Current toggle
[Ue] Rated Operational Voltage 690 V AC 50/60 Hz
Device Short Name NSX100H
EAN13 3606480009020
Mounting Support backplate
Network Type AC
Protected Poles Description 3t
Range ComPact
Range Name ComPact NSX
Suitability For Isolation yes conforming to EN/IEC 60947-2
Trip Unit Protection Functions LI
Trip Unit Technology thermal-magnetic
Utilisation Category category A
COMPLEMENTARY
Communication Network Type 690 V AC 50/60 Hz
Current Transformer Type H 70 kA 415 V AC
Interlocked Device 10 kA at 600 V AC 50/60 Hz conforming to UL 508
10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 480 V AC 50/60 Hz conforming to UL 508
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 240 V AC 50/60 Hz conforming to UL 508
Product Name ComPact NSX
[Ics] Rated Service Breaking Capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
[In] Rated Current 80 A at 40 °C
Compatibility Code NSX100
Connection Pitch 35 mm
Depth 86 mm
Device Application distribution
Downside Connection front
Earth-leakage Protection without
Electrical Durability 10000 cycles at 690 V In
20000 cycles at 690 V In/2
30000 cycles at 440 V In
50000 cycles at 440 V In/2
Height 161 mm
Long Time Delay Adjustment Type fixed
Long Time Pick-up Adjustment Range 0.7...1 x In
Long Time Pick-up Adjustment Type Ir adjustable
Mechanical Durability 50000 cycles
Mounting Mode fixed
Net Weight 2.05 kg
Network Frequency 50/60 Hz
Number Of Slots 5 slot(s)
Protection Type I : for short-circuit protection (magnetic)
L : for overload protection (thermal)
Short-time Delay Adjustment Type fixed
Short-time Pick-up Adjustment Type Isd fixed
Trip Unit Rating 80-80 A at 40 °C
Upside Connection front
Width 105 mm
[Isd] Short-time Pick-up Adjustment Range 640 A
[tr] Long-time Delay Adjustment Range 120-400 s at 1.5 x In
15-15 s at 6 x Ir
[Uimp] Rated Impulse Withstand Voltage 8 kV
[Ui] Rated Insulation Voltage 800 V AC 50/60 Hz
ENVIRONMENT
Ambient Air Temperature For Operation -25-70 °C
Ambient Air Temperature For Storage -50-85 °C
Electrical Shock Protection Class class II
IK Degree Of Protection IK07 conforming to IEC 62262
IP Degree Of Protection IP40 conforming to IEC 60529
Operating Altitude 0...2000 m without derating
2000 m...5000 m with derating
Overvoltage Category class II
Pollution Degree 3 conforming to IEC 60664-1
Product Certifications CCC
EAC
Marine
Relative Humidity 0-95 %
Standards EN/IEC 60947
OTHER
Earth Leakage Current TM-D
Poles Description 3P
[Us] Rated Supply Voltage ComPact NSX100...250
S$ 395.50
(exc. GST)
S$ 431.10
(inc. GST)
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.