Schneider Electric CA2SK20P7 Control Relay, Tesys Sk, 2NO, <= 690V, 230V Ac Coil
Schneider Electric CA2SK20P7 Control Relay, Tesys Sk, 2NO, <= 690V, 230V Ac Coil
Image
Image
Specifications
infotip-icon
View other Control Relays dimensions or variations
Please select at least one specification below.
Utilisation Category
DC-13 AC-15
Standards
EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947 690 V conforming to VDE 0110 group C 690 V conforming to BS 5424 690 V conforming to UL 508 690 V conforming to CSA C22.2 No 14
Mounting Support
Plate Rail
Ip Degree Of Protection
IP2X
Ambient Air Temperature For Operation
-20…50 °C
Mechanical Durability
10 Mcycles
Ambient Air Temperature For Storage
-50…70 °C
[Ith] Conventional Free Air Thermal Current
10 A (at 55 °C)
Product Certifications
CB Scheme cULus EAC CE UKCA
Connections - Terminals
Screw clamp terminals 1 cable(s) 1.5…6 mm²solid Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.5…6 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.35…6 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.35…1.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 0.35…2.5 mm²flexible without cable end
This spec is not available in the specification table.
Tightening Torque
0.8 N.m - on screw clamp terminals pozidriv No 1 screw head
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys CASK
This spec is not available in the specification table.
Operating Altitude
2000 m without derating
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
<= 690 V <= 400 Hz
This spec is not available in the specification table.
Contactor Application
Control circuit
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
230 V AC 50/60 Hz
This spec is not available in the specification table.
Pole Contact Composition
2 NO
This spec is not available in the specification table.
Associated Fuse Rating
10 A gL conforming to VDE 0660 10 A gL conforming to IEC 60947
This spec is not available in the specification table.
Control Circuit Type
AC at 50/60 Hz
This spec is not available in the specification table.
Control Circuit Voltage Limits
Drop-out: 0.2...0.75 Uc (at <50 °C) Operational: 0.85...1.1 Uc (at <50 °C)
This spec is not available in the specification table.
Inrush power in VA
16 VA (at 20 °C)
This spec is not available in the specification table.
Hold-In Power Consumption In Va
4.2 VA (at 20 °C)
This spec is not available in the specification table.
Heat Dissipation
1.4 W
This spec is not available in the specification table.
Operating Time
6...8 ms coil de-energisation and NO opening 7...14 ms coil energisation and NO closing
This spec is not available in the specification table.
Maximum Operating Rate
1200 cyc/h
This spec is not available in the specification table.
Protective Treatment
TC conforming to IEC 60068
This spec is not available in the specification table.
Product Description
S$ 70.00
(exc. GST)
S$ 76.30
(inc. GST)
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Control Relays
37 Items
control-relays-img
Utilisation Category
DC-13 AC-15 AC-14, AC-14 AC-15 DC-13, AC-14 DC-13 AC-15, AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1, AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1
Standards
EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1, IEC 61984, IEC 60255-6, IEC 60255-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947 690 V conforming to VDE 0110 group C 690 V conforming to BS 5424 690 V conforming to UL 508 690 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947 750 V conforming to VDE 0110 group C 690 V conforming to BS 5424 600 V conforming to CSA C22.2 No 14, 400 V, 250 V conforming to IEC 60664-1, 250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1
Ip Degree Of Protection
IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529, IP20 conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 IP30 (housing) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Ambient Air Temperature For Operation
-40…60 °C 60…70 °C with derating, -20…60 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz AC/DC, -25…85 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz
Mechanical Durability
20 Mcycles, 30 Mcycles, 10 Mcycles, 10000000 cycles, 30000000 cycles
Ambient Air Temperature For Storage
-50…80 °C, -60…80 °C, -50…70 °C, -40…85 °C, -40…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Control Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Control Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top