5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Ambient Air Temperature For Operation
-10…40 °C (without derating)
40…50 °C (with current derating of 2 % per °C)
Ambient Air Temperature For Storage
-25…70 °C conforming to EN/IEC 60947-4-2
Motor Power Kw
3 kW, 3 phases at 380...415 V
1.5 kW, 3 phases at 380...415 V
2.2 kW, 3 phases at 380...415 V
Product Certifications
UL
CSA
GOST
C-Tick
CCC
Supply Voltage Limits
342…456 V
Supply Frequency
50...60 Hz - 5...5 %
Device Short Name
ATS01
This spec is not available in the specification table.
Product Or Component Type
Soft starter
This spec is not available in the specification table.
Utilisation Category
AC-53B conforming to EN/IEC 60947-4-2
This spec is not available in the specification table.
Compatibility Code
ATS01N2
This spec is not available in the specification table.
Operating Altitude
<= 1000 m without derating
> 1000 m with current derating of 2.2 % per additional 100 m
This spec is not available in the specification table.
Tightening Torque
1.9…2.5 N.m
0.5 N.m
This spec is not available in the specification table.
Marking
CE
This spec is not available in the specification table.
Electromagnetic Compatibility
Conducted and radiated emissions level B conforming to CISPR 11
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
EMC immunity level 3 conforming to EN 50082-1
EMC immunity level B conforming to EN 50082-2
Harmonics level 3 conforming to IEC 1000-3-2
Harmonics level 3 conforming to IEC 1000-3-4
Immunity to conducted interference caused by radio-electrical fields level 3 conforming to IEC 61000-4-6
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Micro-cuts and voltage fluctuation conforming to IEC 61000-4-11
Voltage/current impulse level 3 conforming to IEC 61000-4-5
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
Built into the starter
This spec is not available in the specification table.
Minimum Switching Current
10 mA at 6 V DC for relay outputs
This spec is not available in the specification table.
Operating Position
Vertical +/- 10 degree
This spec is not available in the specification table.
Product Specific Application
Simple machine
This spec is not available in the specification table.
Shock Resistance
15 gn for 11 ms conforming to EN/IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
This spec is not available in the specification table.
[Us] Rated Supply Voltage
380...415 V - 10...10 %
This spec is not available in the specification table.
Product Destination
Asynchronous motors
This spec is not available in the specification table.
Output Voltage
<= power supply voltage
This spec is not available in the specification table.
Discrete Input Voltage
24...40 V
This spec is not available in the specification table.
Assembly Style
With heat sink
This spec is not available in the specification table.
Current Consumption
30 A at nominal load
This spec is not available in the specification table.
Maximum Switching Current
Relay outputs: 2 A at 250 V AC cos phi = 0.5 and L/R = 20 ms inductive load
Relay outputs: 2 A at 30 V DC cos phi = 0.5 and L/R = 20 ms inductive load
This spec is not available in the specification table.
Electrical Connection
4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit
Screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit
4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit
Screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit
Screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit
4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit
Screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit
4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit
4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit
Screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit
This spec is not available in the specification table.
Network Number Of Phases
3 phases
This spec is not available in the specification table.
Function Available
Integrated bypass
This spec is not available in the specification table.
Discrete Input Logic
Positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA
This spec is not available in the specification table.
Discrete Output Voltage
24 V (voltage limits: 6...30 V) open collector logic
This spec is not available in the specification table.
Discrete Output Current
2 A DC-13
3 A AC-15
This spec is not available in the specification table.
Power Dissipation In W
4 W at full load and at end of starting
64 W in transient state
This spec is not available in the specification table.
Display Type
1 LED (green) for starter powered up
1 LED (yellow) for nominal voltage reached
This spec is not available in the specification table.
Type Of Start
Start with voltage ramp
This spec is not available in the specification table.
Discrete Input Type
Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm
This spec is not available in the specification table.
Discrete Output Type
Open collector logic LO1 end of starting signal
Relay outputs R1A, R1C NO
This spec is not available in the specification table.
Motor Power Range Ac-3
1.1…2 kW at 380…440 V 3 phases
2.2…3 kW at 380…440 V 3 phases
This spec is not available in the specification table.
Icl Starter Rating
6 A
This spec is not available in the specification table.
Starting Time
1 s / 100
5 s / 20
10 s / 10
Adjustable from 1 to 10 s
This spec is not available in the specification table.
Starting Torque
30...80 % of starting torque of motor connected directly on the line supply
This spec is not available in the specification table.
Motor Starter Type
Soft starter
This spec is not available in the specification table.
Deceleration Time Symb
Adjustable from 1 to 10 s
This spec is not available in the specification table.