Ratings
Operating indicator -LED
Degree of protection -Closed type (cover)
Terminal structure -Plug-in terminal
Coil ratings -24 VDC 37.7 mA
Coil resistance -636 Ω
Operate voltage (Set voltage) -80% max.
Release voltage (Reset voltage) -10% min.
Maximum voltage -110% (23 ℃)
Power consumption - Approx. 0.9 W
Contact rated load -250 VAC 5 A (Resistive load)
250 VAC 2 A (Inductive load (cosφ = 0.4))
30 VDC 5 A (Resistive load)
30 VDC 2 A (Inductive load (L/R = 7 ms))
Max. contact voltage -250 VAC, 125 VDC
Max. contact current -AC: 10 A, DC: 10 A
Maximum switching power -2500 VA (Resistive load)
500 VA (Inductive load (cosφ = 0.4))
300 W (Resistive load)
60 W (Inductive load (L/R = 7 ms))
Contact form -DPDT
Contact method -Single
Contact material -Ag
Performance
Contact Resistance -50 mΩ max. (Voltage drop method with 5 VDC 1 A)
Operating time 20 ms max. (With rated operating power applied, not including contact bounce)
Reset time - 20 ms max. (With rated operating power applied, not including contact bounce)
Maximum operating frequency -Mechanical: 18000 time/hour. Rated load: 1800 time/hour
Insulation resistance -Between coil and contacts: 100 MΩ min. (at 500 VDC)
Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
Dielectric strength -Between coil and contacts: 2000 VAC 50/60 Hz 1 min
Between contacts of different polarity: 2000 VAC 50/60 Hz 1 min
Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min
Vibration resistance (destruction) - 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Vibration resistance (Malfunction) - 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Shock resistance (destruction) - 1000 m/s2
Shock resistance (Malfunction) -200 m/s2
Endurance (Mechanical) -100 million operations min. (switching frequency 18,000 operations/h)
Endurance (Electrical) - 500,000 operations min. (23 ℃, Rated load, switching frequency 1,800 operations/h)
Failure rate - 1 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute)
Ambient temperature (Operating) -55 to 70 ℃ (with no freezing or condensation)
Ambient humidity (Operating) -5 to 85%
Weight -Approx. 35 g
Mounting method -Socket