Shopping List
Shopping List
SGD - S$
Image
/
/
/
Lumberg Automation 935001052 0960 IOL 385-001-PX0 LioN-P, IO-Link I/O Hub, 10DI 6DO (8x M12), Class B, Metal, 60 Mm, PX0
Lumberg Automation 935001052 0960 IOL 385-001-PX0 LioN-P, IO-Link I/O Hub, 10DI 6DO (8x M12), Class B, Metal, 60 Mm, PX0
Image
Image
Product Description

Lumberg Automation 935001052 0960 IOL 385-001-PX0 LioN-P, IO-Link I/O Hub, 10DI 6DO (8x M12), Class B, Metal, 60 Mm, PX0

  • Product Family: I/O Systems: Active - Standalone
  • Product Sub Family: LioN-P
  • Item Description: 0960 IOL 385-001-PX0
  • Device Type: IO-Link Hub
  • Protocol: IO-Link
  • I/O Function: 10 Digital Inputs (DI), 6 Digital Outputs (DO)
  • Bus Connection: M12, 5-poles, A-coded
  • Power Connection (System Supply): M12, 5-poles, A-coded
  • I/O Connection: M12, 5-poles, A-coded
  • I/O Type: Digital Input and Digital Output

General Specifications:

  • Housing Material: Metal, Zinc Die-cast
  • Housing Plating: Nickel, matt
  • Housing Color: Grey Metallic
  • Protection Degree / IP Rating: IP65, IP67, IP69K (only when mounted and locked with Hirschmann/Lumberg Automation connector)
  • Potted: Yes
  • Dimensions: 60 mm x 31 mm x 159 mm
  • Weight: 390 g
  • Ambient Temperature (Operation): -20 °C to 70 °C
  • Ambient Temperature (Storage/Transport): -25 °C to 85 °C
  • Permissible Humidity (Operation): 5% - 95% (max. 80% for UL applications)
  • Permissible Humidity (Storage/Transport): 5% - 95% (max. 80% for UL applications)
  • Air Pressure (Operation): 80 kPa - 106 kPa (up to 2000 m above sea level)
  • Air Pressure (Storage/Transport): 80 kPa - 106 kPa (up to 2000 m above sea level)
  • Flammability Class: UL 94 (IEC 61010)
  • Protection Class: III, IEC 61140, EN 61140, VDE 0140-1
  • Pollution Degree: 3 acc. to EN 60664-1, VDE 0110-1
  • Vibration Resistance: 15 g / 5 - 500 Hz
  • Shock Resistance: 50 g / 11 ms
  • Mean Time To Failure (MTTF): 1781 years (according to Telcordia SR-332, 2011, 20°C)

Electrical Specifications:

  • Modbus TCP:
    • Connection: M12, 5-poles, A-coded
    • Protocol: IO-Link
    • IO-Link Class: B
    • Number of Connections: 1
    • Specification: V1.1.2
    • Transmission Rate / COM Mode: COM 3 (230.4 kbps)
    • Cycle Time / Update Rate: min. 1 ms
    • Parameter Storage: Supported
    • Frame Type: Type_2_V
    • Process Data Length: 4 Bytes Input Data, 4 Bytes Output Data
    • Configuration: IODD, Process Data

Power Supply:

  • Module Supply Voltage: 24 V DC (SELV/PELV), Range: 18 V DC to 30 V DC
  • Current Consumption: 80 mA (at 24 V DC)
  • Reverse Polarity Protection: Yes
  • Status Indicators:
    • Green (System, Sensor, Actuator supply)
    • Red (Diagnostic)

Digital Inputs:

  • Number of Digital Input Channels: Max. 10, fixed
  • Connection: M12, 5-poles, A-coded
  • Ports: X1 to X5 (5 ports)
  • Channel Type: Type 3 (IEC 61131-2)
  • Sensor Current Supply: Max. 700 mA per module
  • Input Wiring: 2-, 3-, 4-wire
  • Nominal Voltage: 24 V DC via US (module power supply)
  • Nominal Current: 5 mA
  • Sensor Type: PNP
  • Input Voltage Range:
    • "0" signal: -3 V DC to +5 V DC
    • "1" signal: 11 V DC to 30 V DC
  • Input Filter Time: 0 to 3 ms, configurable
  • Protective Circuit: Overload protection, short-circuit protection
  • Status Indicators: LED white or yellow per channel
  • Diagnostic Indicators: LED red per port

Digital Outputs:

  • Number of Digital Output Channels: Max. 6, fixed
  • Connection: M12, 5-poles, A-coded
  • Ports: X6 to X8 (3 ports)
  • Channel Type: P-switching
  • Output Current per Channel: Max. 0.5 A
  • Output Wiring: 2-, 3-wire
  • Nominal Voltage: 24 V DC (supplied by 2L+ of IO-Link Master)
  • Galvanically Isolated: Yes
  • Protective Circuit: Overload protection, short-circuit protection
  • Overload Behavior: Auto-off and on switching / Manual restart
  • Status Indicators: LED white or yellow per channel
  • Diagnostic Indicators: LED red per channel

Electrical Isolation:

  • US (System Supply Voltage) / FE: 500 V DC
  • Uaux / FE: 500 V DC
  • Bus connection / FE: 500 V DC

EMC Conformance:

  • EMC Directive: 2014/30/EU
  • ESD: Criterion B, 4 kV contact discharge, 8 kV air discharge
  • Electromagnetic Field: Criterion A, Field intensity: 10 V/m
  • Fast Transients (Burst): Criterion B, 2 kV
  • Surge Voltage: ±0.5 kV/±0.5 kV
  • Conducted Immunity: Criterion A, Test voltage 10 V
  • Radio Interference Properties: Class A

Compliance and Approvals:

  • CE: Yes
  • RoHS Compliant: Yes
  • China RoHS-Compliant: Yes
  • UL: cULus Listed, UL 61010-1
  • CSA: Yes, via UL
  • IO-Link: Yes

Mounting Information:

  • Mounting Type: 2-hole screw mounting using M4 x 25 / 30 screws with toothed lock washer (DIN 125) and self-locking nuts.
  • Fastening Torque:
    • Fixing Screw (M4): 1 Nm
    • Ground Connection (FE) (M4): 1 Nm
    • Bus, Power, I/O Connections (M12): 0.5 Nm

Notes:

  • Protection Degree / IP Rating: IP rating only if mounted and locked in combination with Hirschmann / Lumberg Automation connector.
  • System Power Supply Connection: Do not connect or disconnect under voltage.
S$ 493.04
(exc. GST)
S$ 537.41
(inc. GST)
UnitsDiscountUnit Price
1-S$ 493.04
Image
Lead time of 126 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
This item is sold by
Image
SG-1400063614
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
IO-Link Hubs from Lumberg Automation
Source & compare similar products
More from IO-Link Hubs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top