Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Abb PSR30-600-70 Soft Starter 600V 18.5KW
Abb PSR30-600-70 Soft Starter 600V 18.5KW
Brand:
ABB
Model:
PSR30-600-70
Image
Image
Product Description

Abb PSR30-600-70 Soft Starter 600V 18.5KW


  • The softstarter PSR30-600-70 has a rated maximum operational current of 30 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN and a TOR signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.
  • Product Net Width:128 mm
  • Product Net Height:160 mm
  • Product Net Depth / Length:45 mm
  • Product Net Weight:0.6 kg
  • Unit of measurement : Pcs

Technical

  • Rated Operational Voltage:208 ... 600 V AC
  • Rated Control Supply Voltage (Us):100 ... 240 V AC
  • Rated Control Circuit Voltage (Uc):24 V DC
  • Rated Frequency (f):50/60 Hz
  • Main Circuit 50 / 60 Hz
  • Rated Operational Power - In-Line Connection (Pe):(230 V) 7.5 kW
  • (400 V) 15 kW
  • (500 V) 18.5 kW
  • Rated Operational Current - In-Line Connection (Ie):30 A
  • Service Factor Percentage:100 %
  • Overload Protection:Recommended MS132 25 ... 32
  • Integrated Electronic Overload:No
  • Adjustable Rated Motor Current Ie:No
  • Starting Capacity at Maximum Rated Current Ie:4xIe for 6s
  • Ramp Time:0 ... 20 second [unit of time]
  • 1 ... 10 second [unit of time]
  • Initial Voltage During Start:40 ... 70 %
  • Step Down Voltage Special Ramp:100 ... 60 %
  • Current Limit Function:No
  • Switch for Inside Delta Connection:No
  • Run Signal Relay:Yes
  • By-pass Signal Relay:Yes
  • Fault Signal Relay:No
  • Overload Signal Relay:No
  • Signal Indication Completed Start Ramp (LED):Green
  • Signal Indication Ready to Start/Standby ON (LED):Green
  • Signal Indication Running R (LED):Green
  • Signal Indication Ramping Up/Down (LED):Green
  • Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:10
  • Communication:FiledBusPlug(Optional)
  • Degree of Protection:IP20
  • Terminal Type:Screw Terminals
  • Connecting Capacity Main Circuit:Rigid 1/2 x 2.5 ... 10 mm²
  • Connecting Capacity Control Circuit:1 x 0.75 ... 2.5
  • 2 x 0.75 ... 2.5 mm²
  • Rigid 1 x 0.75 ... 2.5 mm²
  • Rigid 2 x 0.75 ... 1.5 mm²
  • Connecting Capacity Supply Circuit:Rigid 1 x 0.75 ... 2.5 mm²
  • Tightening Torque:Control Circuit 0.6 N·m
  • Main Circuit 2.3 N·m
  • Supply Circuit 0.6 N·m
  • Product Main Type:PSR30
  • Function:Soft start with voltage ramp
  • Soft stop with voltage ramp
S$ 948.00
(exc. GST)
S$ 1,033.32
(inc. GST)
Image
Restocking
Contact us at enquiry@eezee.com.sg or +65 6797 9688 for more details. Item will take longer than normal to be delivered.
Quantity:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Motor Starter
194 Items
motor-starter-img
Rated Current
6 A, 250 A, 480 A, 790 A, 320 A
Rated Voltage
220 V, 5 V, 208 V ac, 208 → 690 V ac, 240 V
Standards and Certifications
CE, CSA, CSA C22.2 No 14, C-Tick, EAC, EN 61131-2, EN/IEC 60068-2-27, EN/IEC 60068-2-30, EN/IEC 60068-2-6, EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-6, IEC 60068-2-27, IEC 61131-2, NOM, UL, UL 508, CCC, CE, CSA, UL, RoHS Compliant, ABS, ATEX, BV, CCC, CSA, CSA C22.2 No. 14, C-TICK, DNV, EAC, EN 60947-4-1, EN/IEC 60068, EN/IEC 60068-2-30, EN/IEC 60070-2-11, EN/IEC 60695-2-12, EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 61000-4-5, GL, IACS E10, IEC 60947-4-1, KERI, LROS (Lloyds register of shipping), NOM, RINA, RMRoS, UL, UL 508, UL 94, CSA, UL
Coil Voltage
110...240 V AC 110...220 V DC, 24 V AC, 380 V AC 50/60 Hz, 415 V AC 50/60 Hz, 220 V AC 50/60 Hz
Width
30 mm, 88 mm, 175 mm, 22.5 mm, 144 mm
Depth
146 mm, 135 mm, 165 mm, 114.5 mm, 170 mm
[Uimp] Rated Impulse Withstand Voltage
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1, 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1, 6 kV conforming to IEC 60947-6-2, 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1, 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Starter from ABB
Source & compare similar products
More from Motor Starter
Expand your search with a wider selection
Recently Viewed Products