Abb ESB25-40N-06 Contactor Installation 25A 4NO 4P
Abb ESB25-40N-06 Contactor Installation 25A 4NO 4P
Brand:
ABB
Model:
ESB25-40N-06
Image
Image
Product Description

Abb ESB25-40N-06 Contactor Installation 25A 4NO 4P

  • Extended Product Type:ESB25-40N-06
  • Product ID:1SAE231111R0640
  • EAN:4013614517952
  • Catalog Description:ESB25-40N-06 Installation Contactor (NO) 25 A - 4 NO - 0 NC - 230 ... 240 V - Control Circuit 400 Hz
  • Long Description:The ESB25..N installation contactors are used to control single and three-phase loads up to 25 A and can be operated by AC or DC.
  • These contactors are made for use in household applications as well as in industrial environments.
  • The following benefits are provided:
  • Hum-free operation, low power consumption and integrated overvoltage protection.
  • Various contact combinations and accessories are available.
  • Unit of Measurement : PCS

Technical

  • Rated Operational Voltage:Main Circuit 220 V DC
  • Main Circuit 400 V AC
  • Rated Control Circuit Voltage (Uc):230 ... 240 V
  • Rated Frequency (f):Control Circuit 400 Hz
  • Control Circuit 50 Hz
  • Control Circuit 60 Hz
  • Control Circuit DC
  • Main Circuit 50 Hz
  • Main Circuit 60 Hz
  • Main Circuit DC
  • Rated Operational Current AC-1 (Ie):(NO) 25 A
  • Rated Operational Current AC-3 (Ie):(230 V) Single Phase, NO 9 A
  • (400 V) Three Phase, NO 9 A
  • Rated Operational Power AC-1 (Pe):(230 V) Single Phase, NO 5.8 kW
  • (400 V) Three Phase, NO 17.3 kW
  • Rated Operational Power AC-3 (Pe):(230 V) Single Phase, NO 1.3 kW
  • (400 V) Three Phase, NO 4 kW
  • Rated Operational Current AC-7a (Ie):(NO) 25 A
  • Rated Operational Power AC-7a (Pe):(230 V) Single Phase, NO 5.8 kW
  • (400 V) Three Phase, NO 17.3 kW
  • Rated Operational Current AC-7b (Ie):(230 V) Single Phase, NO 9 A
  • (400 V) Three Phase, NO 9 A
  • Rated Operational Power AC-7b (Pe):(230 V) Single Phase, NO 1.3 kW
  • (400 V) Three Phase, NO 4 kW
  • Recommended Screw Driver:Control Circuit Pozidriv 1
  • Main Circuit Pozidriv 1
  • Rated Impulse Withstand Voltage (Uimp):6 kV
  • Rated Insulation Voltage (Ui):500 V
  • Connecting Capacity Main Circuit:Flexible with Ferrule 1x 1.5 ... 10 mm²
  • Flexible with Ferrule 2x 1.5 ... 2.5 mm²
  • Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
  • Flexible with Insulated Ferrule 2x 1.5 mm²
  • Flexible 1x 1.5 ... 10 mm²
  • Flexible 2x 1.5 ... 4 mm²
  • Rigid 1x 1.5 ... 10 mm²
  • Rigid 2x 1.5 ... 4 mm²
  • Connecting Capacity Control Circuit:Flexible with Ferrule 1x 1 ... 2.5 mm²
  • Flexible with Ferrule 2x 0.75 ... 1 mm²
  • Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
  • Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
  • Flexible 1x 1 ... 4.0 mm²
  • Flexible 2x 1 ... 2.5 mm²
  • Rigid 1x 1 ... 4 mm²
  • Rigid 2x 1 ... 2.5 mm²
  • Tightening Torque:Control Circuit 0.9 N·m
  • Main Circuit 1 N·m
  • Wire Stripping Length:Control Circuit 7 mm
  • Main Circuit 10 mm
  • Degree of Protection:IP20
  • Electrical Durability:AC-1 (NO) 130000 cycle
  • AC-3 (NO) 500000 cycle
  • AC-7a (NO) 130000 cycle
  • AC-7b (NO) 500000 cycle
  • Mechanical Durability:1000000 cycle
  • Number of Poles:4
  • Number of Auxiliary Contacts NC:0
  • Number of Auxiliary Contacts NO:0
  • Number of Main Contacts NC:0
  • Number of Main Contacts NO:4
  • Width in Number of Modular Spacings:2
  • Pollution Degree:3
  • Standards:IEC/EN 60947-1
  • IEC/EN 60947-4-1
  • IEC/EN 61095
  • UL 60947-1
  • UL 60947-4-1
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contactors from ABB
Source & compare similar products
More from Contactors
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top