Abb AF146-30-11-13 Contactor 3P 75KW 1NO 1NC 50/60HZ 100-250VAC/DC
Abb AF146-30-11-13 Contactor 3P 75KW 1NO 1NC 50/60HZ 100-250VAC/DC
Brand:
ABB
Model:
AF146-30-11-13
Image
Image
Product Description

Abb AF146-30-11-13 Contactor 3P 75KW 1NO 1NC 50/60HZ 100-250VAC/DC

  • Extended Product Type:AF146-30-11-13
  • Product ID:1SFL467001R1311
  • EAN:7320500476994
  • Catalog Description:AF146-30-11-13 Contactor
  • Long Description:The AF146-30-11-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and double clamp, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
  • Number of Main Contacts NO:3
  • Number of Main Contacts NC:0
  • Number of Auxiliary Contacts NO:1
  • Number of Auxiliary Contacts NC:1
  • Rated Operational Voltage:Main Circuit 1000 V
  • Rated Frequency (f):Main Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 225 A
  • Rated Operational Current AC-1 (Ie):(1000 V) 40 °C 225 A
  • (1000 V) 55 °C 200 A
  • (1000 V) 60 °C 200 A
  • (1000 V) 70 °C 175 A
  • (690 V) 40 °C 225 A
  • (690 V) 55 °C 200 A
  • (690 V) 60 °C 200 A
  • (690 V) 70 °C 175 A
  • Rated Operational Current AC-3 (Ie):(415 V) 55 °C 146 A
  • (440 V) 55 °C 146 A
  • (500 V) 55 °C 130 A
  • (690 V) 55 °C 93 A
  • (1000 V) 55 °C 60 A
  • (380 / 400 V) 55 °C 146 A
  • (220 / 230 / 240 V) 55 °C 146
  • Rated Operational Current AC-3e (Ie):(415 V) 60 °C 146 A
  • (440 V) 60 °C 146 A
  • (500 V) 60 °C 130 A
  • (690 V) 60 °C 93 A
  • (1000 V) 60 °C 54 A
  • (380 / 400 V) 60 °C 146 A
  • (220 / 230 / 240 V) 60 °C 146 A
  • Rated Operational Power AC-3 (Pe):(415 V) 75 kW
  • (440 V) 90 kW
  • (500 V) 90 kW
  • (690 V) 90 kW
  • (1000 V) 75 kW
  • (380 / 400 V) 75 kW
  • (220 / 230 / 240 V) 45 kW
  • Rated Operational Power AC-3e (Pe):(415 V) 75 kW
  • (440 V) 90 kW
  • (500 V) 90 kW
  • (690 V) 90 kW
  • (1000 V) 75 kW
  • (380 / 400 V) 75 kW
  • (220 / 230 / 240 V) 45 kW
  • Rated Breaking Capacity AC-3:8 x Ie AC-3
  • Rated Breaking Capacity AC-3e:8.5 x Ie AC-3e
  • Rated Making Capacity AC-3:10 x Ie AC-3
  • Rated Making Capacity AC-3e:12 x Ie AC-3e
  • Short-Circuit Protective Devices:gG Type Fuses 315 A
  • Rated Short-time Withstand Current Low Voltage (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
  • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
  • cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
  • Maximum Electrical Switching Frequency:(AC-1) 300 cycles per hour
  • (AC-2 / AC-4) 150 cycles per hour
  • (AC-3) 300 cycles per hour
  • Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):Main Circuit 8 kV
  • Mechanical Durability:5 million
  • Maximum Mechanical Switching Frequency:300 cycles per hour
  • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
  • Rated Control Circuit Voltage (Uc):50 Hz 100 ... 250 V
  • 60 Hz 100 ... 250 V
  • DC Operation 100 ... 250 V
  • Coil Consumption:Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
  • Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
  • Holding at Max. Rated Control Circuit Voltage DC 3 W
  • Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
  • Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
  • Pull-in at Max. Rated Control Circuit Voltage DC 135 W
  • Operate Time:Between Coil De-energization and NO Contact Opening 37 ... 47 ms
  • Between Coil Energization and NO Contact Closing 25 ... 55 ms
  • Connecting Capacity Main Circuit:Flexible 1 x 10 ... 70 mm²
  • Rigid Cu-Cable 1 x 10 ... 95 mm²
  • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
  • Flexible 2x0.75 ... 2.5 mm²
  • Solid 2 x 1 ... 4 mm²
  • Stranded 1 x 1 .... 4 mm²
  • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type:Double Clamp
  • Unit of Measurement : Pcs
S$ 748.00
(exc. GST)
S$ 815.32
(inc. GST)
Image
This product will be active soon.
Image
Lead time of 30 working days required.
Item will be ready to dispatch within the lead time specified.
Image
Restocking
Contact us at enquiry@eezee.com.sg or +65 6797 9688 for more details. Item will take longer than normal to be delivered.
Quantity:
/ EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contactors from ABB
Source & compare similar products
More from Contactors
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top