Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Tenmars TM-801 Carbon Monoxide Co & Temperature Meter
Tenmars TM-801 Carbon Monoxide Co & Temperature Meter
Merek:
TENMARS
Model:
TM-801
Image
Image
Image
Image
Image
Image
Deskripsi Produk

CO/Temp Meter (with adjustable alarm)
Measures of Carbon Monoxide and Temperature
(Model No.: TM- 801)

Quality Product ~ Made in Taiwan

TM-801 CO meter is used for measuring the CO levels upto 1000ppm.

Carbon monoxide (CO) is a poisonous gas that has no smell, color or taste. But it is very dangerous and reduces the oxygen-carrying capacity of blood that causes you unwell, illness and death.

Features:

  • 4 digital LCD with maximum 1000 counts.
  • CO range: 0 ~ 1,000ppm.
  • Temperature range: -20~50 ºC (-4~122 ºF).
  • Sample rate: 1 time/second
  • Dual and digital display of the CO and temperature measuring
  • Max/Min/Average Hold.
  • Data Hold.
  • Low battery indication
  • Auto power off with disable function.
  • Adjustable alarm: Adjustable alarm threshold level (25 /35 /50 /100 /250 /400 /800 /Randomly adjustable); Enable/Disable alarm
  • LED Backlight.
  • Auto power OFF and disable function.

Specifications:

  • CO Measurement:
    • Range: 0 ~ 1000ppm
    • Resolution: ±1ppm
    • Accuracy: ±5% or ±2ppm
    • Repeatability: < 2%
    • Response time※: < 30 seconds.
    • Zero drift in long term: < 5ppm
    • Sensitivity drift: < 5% (per year)
    • Typical sensor life: 3 years
  • Temperature Measurement:
    • Range: -20~50℃/-4~122℉
    • Resolution: ±0.1℃/±0.1℉
    • Accuracy: ±1.0℃/±1.8℉
  • Power supply: 1.5V UM-4(AAA) battery × 6 PCS or AC100~240V or DC Adaptor 9V/0.5A(9mm).
  • Battery life: approx 90 hours.
  • Operating Temperature & Humidity: -20°C to +50°C, <80% RH.
  • Storage Temperature & Humidity : -10°C to +50°C, <70% RH.
  • Dimension: 156×73×35mm(LxWxH).
  • Weight: approx 250g (Batteries not included).

Standard accessories:

  • UM-4(AAA)1.5V battery ×6 PCS, user’s manual, carrying pouch.

CO LEVELS AND STANDARD:

Carbon monoxide content in the air | Inspiration time | Symptoms and applicable standard

  • 0-1 ppm : Normal background levels.
  • 9 ppm : Maximum indoor air quality level.
  • 35 ppm | 8 hours : The average exposure level per U.S. OSHA workplace standards.
  • 50 ppm | 8 hours : The maximum average exposure of the U.S. OSHA workplace standards.
  • 0.01%(100 ppm) | 2~3 hours : Evacuate people from enclosed space if the CO concentration exceeds 100 ppm per OSHA exposure limit. Mild headache.
  • 0.04%(400 ppm) | 1~2 hours : Headache occur in 2.5 hours to 3.5 hours.
  • 0.08%(800 ppm) | 45-min : Dizziness, nausea, cramps(convulsions).
  • 0.16%(1600 ppm) | 20-min : Headache, dizziness and will be dead within 2 hours.
  • 0.32%(3200 ppm) | 5~10 min : Headache, dizziness, vomiting and will be dead in 30 minutes.
  • 0.64%(6400 ppm) | 1~2 min : Headache, dizziness and will be dead within10 to 15 minutes.
  • 1.28%(12800 ppm) | 1~3 min : Cause death.

Standards Certification:

  • CE
  • ROHS
Rp 2.439.493
Kuantitas:
EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Air Quality Meters dari TENMARS
Temukan dan bandingkan barang serupa
Lebih Dari Air Quality Meters
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas