Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Telemecanique SR2B201BD Relai Cerdas Ringkas, Zelio Logic SR2 SR3, 20 Io, 24V Dc, Jam, Layar, 8 Output Relai
Telemecanique SR2B201BD Relai Cerdas Ringkas, Zelio Logic SR2 SR3, 20 Io, 24V Dc, Jam, Layar, 8 Output Relai
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Programmable Logic Controllers dimensions or variations
Please select at least one specification below.
Product Or Component Type
Compact smart relay
Range Of Product
Zelio Logic
Standards
IEC 61000-4-2 level 3 IEC 61000-4-5 IEC 60068-2-27 Ea IEC 61000-4-12 IEC 61000-4-3 IEC 60068-2-6 Fc IEC 61000-4-6 level 3 IEC 61000-4-4 level 3 IEC 61000-4-11
Ip Degree Of Protection
IP20 (terminal block) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529
Relative Humidity
95 % without condensation or dripping water
Ambient Air Temperature For Operation
-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
Ambient Air Temperature For Storage
-40…70 °C
Operating Altitude
2000 m
Product Certifications
GOST UL CSA C-Tick GL
[Us] Rated Supply Voltage
24 V DC
Overvoltage Category
III conforming to IEC 60664-1
This spec is not available in the specification table.
Pollution Degree
2 conforming to IEC 61131-2
This spec is not available in the specification table.
Discrete Input Number
12 conforming to IEC 61131-2 Type 1
This spec is not available in the specification table.
Discrete Input Voltage
24 V DC
This spec is not available in the specification table.
Discrete Input Current
4 mA
This spec is not available in the specification table.
Input Impedance
12 kOhm for IB...IG used as analogue input circuit 12 kOhm for IB...IG used as discrete input circuit 7.4 kOhm for I1...IA and IH...IR discrete input circuit
This spec is not available in the specification table.
Analogue Input Number
6
This spec is not available in the specification table.
Analogue Input Type
Common mode
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
This spec is not available in the specification table.
Number Of Outputs
8 relay
This spec is not available in the specification table.
Connections - Terminals
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
This spec is not available in the specification table.
Mechanical Durability
10000000 cycles for relay output
This spec is not available in the specification table.
Electrical Durability
AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to IEC 60947-5-1 AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to IEC 60947-5-1 DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to IEC 60947-5-1 DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to IEC 60947-5-1
This spec is not available in the specification table.
Tightening Torque
0.5 N.m
This spec is not available in the specification table.
Environmental Characteristic
EMC directive conforming to IEC 61000-6-2 EMC directive conforming to IEC 61000-6-3 EMC directive conforming to IEC 61000-6-4 EMC directive conforming to IEC 61131-2 zone B Low voltage directive conforming to IEC 61131-2
This spec is not available in the specification table.
Current State 0 Guaranteed
<= 0.75 mA (I1...IA and IH...IR discrete input circuit) <= 0.75 mA (IB...IG used as discrete input circuit)
This spec is not available in the specification table.
Current State 1 Guaranteed
>= 1.2 mA (IB...IG used as discrete input circuit) >= 2.2 mA (I1...IA and IH...IR discrete input circuit)
This spec is not available in the specification table.
Contacts Type And Composition
NO for relay output
This spec is not available in the specification table.
Immunity To Microbreaks
10 ms
This spec is not available in the specification table.
Supply Voltage Limits
19.2…30 V
This spec is not available in the specification table.
Switching Capacity In Ma
>= 10 mA at 12 V (relay output)
This spec is not available in the specification table.
Response Time
10 ms (from state 0 to state 1) for relay output 5 ms (from state 1 to state 0) for relay output
This spec is not available in the specification table.
Local Display
With
This spec is not available in the specification table.
Number Or Control Scheme Lines
0…240 with ladder programming 0…500 with FBD programming
This spec is not available in the specification table.
Cycle Time
6…90 ms
This spec is not available in the specification table.
Backup Time
10 years at 25 °C
This spec is not available in the specification table.
Clock Drift
12 min/year at 0…55 °C 6 s/month at 25 °C
This spec is not available in the specification table.
Checks
Program memory on each power up
This spec is not available in the specification table.
Maximum Supply Current
100 mA (without extension)
This spec is not available in the specification table.
Voltage State 1 Guaranteed
>= 15 V for I1...IA and IH...IR discrete input circuit >= 15 V for IB...IG used as discrete input circuit
This spec is not available in the specification table.
Voltage State 0 Guaranteed
<= 5 V for I1...IA and IH...IR discrete input circuit <= 5 V for IB...IG used as discrete input circuit
This spec is not available in the specification table.
Output Voltage Limits
24...250 V AC (relay output) 5...30 V DC (relay output)
This spec is not available in the specification table.
Output Thermal Current
8 A for all 8 outputs for relay output
This spec is not available in the specification table.
Operating Rate In Hz
0.1 Hz (at Ie) for relay output 10 Hz (no load) for relay output
This spec is not available in the specification table.
Clock
With
This spec is not available in the specification table.
Disturbance Radiated/Conducted
Class B conforming to EN 55022-11 group 1
This spec is not available in the specification table.
Maximum Altitude Transport
3048 m
This spec is not available in the specification table.
Maximum Permissible Voltage
30 V for analogue input circuit
This spec is not available in the specification table.
Repeat Accuracy
+/- 2 % at 55 °C for analogue input circuit
This spec is not available in the specification table.
Analogue Input Resolution
8 bits
This spec is not available in the specification table.
Lsb Value
39 mV for analogue input circuit
This spec is not available in the specification table.
Conversion Time
Smart relay cycle time for analogue input circuit
This spec is not available in the specification table.
Power Dissipation In W
6 W without extension
This spec is not available in the specification table.
Reverse Polarity Protection
With
This spec is not available in the specification table.
Discrete Input Type
Resistive
This spec is not available in the specification table.
Counting Frequency
1 kHz for discrete input
This spec is not available in the specification table.
Input Compatibility
3-wire proximity sensors PNP for discrete input
This spec is not available in the specification table.
Analogue Input Range
0...24 V 0...10 V
This spec is not available in the specification table.
Conversion Error
+/- 5 % at 25 °C for analogue input circuit +/- 6.2 % at 55 °C for analogue input circuit
This spec is not available in the specification table.
Operating Distance
10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
This spec is not available in the specification table.
Temperature Probe Type
NTC 10k at 25 °C NTC 1000k at 25 °C KTY81 210/220/221/222/250 Pt 500
This spec is not available in the specification table.
Deskripsi Produk

Rp 5.304.084
Kuantitas:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Programmable Logic Controllers
45 Items
programmable-logic-controllers-img
Product Or Component Type
Discrete I/O extension module, Modular smart relay, Compact smart relay, Compact discovery packs, Programmable controllers
Range Of Product
Modicon M251, Easy Modicon M200, Modicon M221, Modicon M171/M172, SpaceLogic KNX
Standards
IEC 61131-2 UL 508 CAN/CSA C22.2 No. 213 IACS E10 ANSI/ISA 12-12-01, CAN/CSA-E60730-1<br />CSA E60730-2-9<br />EN 60068-2-27<br />EN 60068-2-6 Fc<br />EN 60730-1<br />EN 60730-2-9<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-2<br />IEC 61000-4-3<br />IEC 61000-4-4<br />IEC 61000-4-5<br />IEC 61000-4-6<br />IEC 61000-4-11<br />UL94 (material V0), IEC 61000-4-5<br />IEC 61000-4-3<br />IEC 61000-4-2<br />EN 60068-2-27<br />EN 60730-1<br />EN 60068-2-6 Fc<br />UL 60730-1<br />UL 60730-2-9<br />IEC 61000-4-4<br />CAN/CSA-E60730-1<br />IEC 61000-4-11<br />IEC 61000-4-6<br />CSA E60730-2-9<br />EN 60730-2-9<br />UL94 (material V0), CSA, UL, CSA Certified, UL Listed
Ambient Air Temperature For Operation
-10…35 °C (vertical installation) -10…55 °C (horizontal installation), -10…50 °C (vertical installation) -10…55 °C (horizontal installation), -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2, -20…65 °C conforming to UL 60730-1<br />-20…60 °C horizontal conforming to UL 60730-1, -20…60 °C conforming to UL 60730-1<br />-20…65 °C with derating conforming to UL 60730-1
Product Certifications
GL C-Tick CSA UL GOST, GOST CSA UL C-Tick GL, DNV-GL EAC ABS cULus LR RCM CE UKCA cULus HazLoc, EAC<br />CE<br />cURus<br />CSA<br />RCM, CSA<br />EAC<br />RCM<br />CE<br />cURus
[Us] Rated Supply Voltage
24 V, 100...240 V AC, 24 V +/- 10 % AC<br />20...38 V DC, 24 V dc, 4.75 → 5.25 V
-
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Programmable Logic Controllers dari Telemecanique
Temukan dan bandingkan barang serupa
Lebih Dari Programmable Logic Controllers
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas