Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Blok Kontak Schneider Electric ZA2EE101, Easy Harmony XA2, Kontak Tunggal, untuk Kepala 22mm, Terminal Faston, 1NO
Blok Kontak Schneider Electric ZA2EE101, Easy Harmony XA2, Kontak Tunggal, untuk Kepala 22mm, Terminal Faston, 1NO
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Contact Block dimensions or variations
Please select at least one specification below.
Contacts type and composition
1 NO
Product Or Component Type
Contact block
Range Of Product
Easy Harmony XA2
Standards
IEC 60947-1 IEC 60947-5-4 IEC 60529 IEC 60947-5-1
[Ui] Rated Insulation Voltage
600 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-1
Ip Degree Of Protection
IP20 conforming to IEC 60529
Contacts Material
Silver alloy (Ag/Ni)
[Ie] Rated Operational Current
2 A at 230 V, AC-15, A600 conforming to IEC 60947-5-1 0.2 A at 110 V, DC-13, Q600 conforming to IEC 60947-5-1
Contact Operation
Slow-break
Connections - Terminals
, <= 2 x 1.5 mm² conforming to IEC 60947-1 , <= 1 x 2.5 mm² conforming to IEC 60947-1 , >= 1 x 0.5 mm² conforming to IEC 60947-1 Faston terminals, connection size: 6.3 mm conforming to IEC 60947-1
This spec is not available in the specification table.
Ambient Air Temperature For Operation
-25…55 °C
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…70 °C
This spec is not available in the specification table.
Positive Opening
Without
This spec is not available in the specification table.
Short-Circuit Protection
10 A fuse type gL conforming to IEC 60269-1
This spec is not available in the specification table.
Device Short Name
ZA2E
This spec is not available in the specification table.
Mechanical Durability
1500000 cycles
This spec is not available in the specification table.
Electrical Durability
500000 cycles, AC-15, 2 A at 230 V, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 500000 cycles, DC-13, 0.2 A at 110 V, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1
This spec is not available in the specification table.
Tightening Torque
0.8 N.m
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
10 A conforming to IEC 60947-5-1
This spec is not available in the specification table.
Product Certifications
CE CCC
This spec is not available in the specification table.
Protective Treatment
TC
This spec is not available in the specification table.
Contact Block Type
Single
This spec is not available in the specification table.
Contacts Usage
Standard contacts
This spec is not available in the specification table.
Deskripsi Produk

Rp 64.647
Kuantitas:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Contact Block
41 Items
contact-block-img
Contacts type and composition
1 NC + 1 NO, 2 NC, 1 C/O + 1 NO, 2 NO + 1 C/O, 1 NC + 2 NO
Range Of Product
Harmony 9001K Harmony 9001SK, Harmony XB6, Harmony XAC, Harmony XAL Harmony XAPS, Harmony XAPS Harmony XAL
Standards
IEC 60947-3 CSA C22.2 No 14 EN 60947-3, EN/IEC 60947-5-1 UL 508 EN/IEC 60204-32 CSA C22.2 No 14, CSA C22.2 No 14 EN/IEC 60947-5-1 UL 508, IEC 60947-5-1 CSA C22.2 No 14 IEC 60947-1 UL 508 IEC 60947-5-5 JIS C8201-5-1 IEC 60947-5-4 JIS C8201-1, IEC 60947-5-5 IEC 60947-5-4 UL 508 JIS C8201-5-1 IEC 60947-1 CSA C22.2 No 14 IEC 60947-5-1 JIS C8201-1
[Ui] Rated Insulation Voltage
600 V (pollution degree 3) conforming to IEC 60947-1, 250 V (pollution degree 3) conforming to IEC 60947-1, 250 V (pollution degree 3) conforming to EN/IEC 60947-1, 500 V (pollution degree 3) conforming to IEC 60947-1, 600 V conforming to CSA
[Uimp] Rated Impulse Withstand Voltage
4 kV conforming to IEC 60947-1, 6 kV conforming to EN 60947-1, 6 kV conforming to IEC 60947-1, 2.5 kV conforming to IEC 60947-1, 4 kV conforming to EN/IEC 60947-1
[Ie] Rated Operational Current
3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1, 2 A at 230 V, AC-15, A600 conforming to IEC 60947-5-1 0.2 A at 110 V, DC-13, Q600 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A600-Q600 conforming to NEMA 0.55 A at 125 V, DC-13, A600-Q600 conforming to NEMA, 3 A at 120 V, AC-15, B300 1.5 A at 240 V, AC-15, B300 0.1 A at 250 V, DC-13, R300 0.22 A at 125 V, DC-13, R300
Contact Operation
Positive opening, Standard, Staggered Snap action, Snap action Staggered, Slow-break Staggered
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contact Block dari SCHNEIDER ELECTRIC
Temukan dan bandingkan barang serupa
Lebih Dari Contact Block
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas