Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Schneider Electric LV540510 Easypact CVS400N Pemutus Sirkuit, 50 kA@415 Vac, 3P 3d, Ets 2.3 Unit Trip 400 A
Schneider Electric LV540510 Easypact CVS400N Pemutus Sirkuit, 50 kA@415 Vac, 3P 3d, Ets 2.3 Unit Trip 400 A
Image
Image
Specifications
infotip-icon
View other Circuit Breaker dimensions or variations
Please select at least one specification below.
Ambient air temperature for operation
-25…70 °C
Poles Description
3P
Protected Poles Description
3D
Network Type
AC
[In] Rated Current
400 A at 40 °C
Network Frequency
50/60 Hz
Standards
EN 60947-2 IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage
8 kV conforming to EN/IEC 60947-2
Ip Degree Of Protection
IP40
Pollution Degree
3 conforming to IEC 60664-1
Ambient Air Temperature For Storage
-50…85 °C
Trip Unit Rating
400 A at 40 °C
Trip Unit Technology
Electronic
This spec is not available in the specification table.
Trip Unit Protection Functions
LSoI
This spec is not available in the specification table.
Control Type
Toggle
This spec is not available in the specification table.
Mounting Mode
Fixed
This spec is not available in the specification table.
Trip Unit Name
ETS 2.3
This spec is not available in the specification table.
Device Short Name
CVS400N
This spec is not available in the specification table.
Product Or Component Type
Circuit breaker
This spec is not available in the specification table.
Range
EasyPact
This spec is not available in the specification table.
Product Name
EasyPact CVS
This spec is not available in the specification table.
Device Application
Distribution
This spec is not available in the specification table.
Connection Pitch
45 mm
This spec is not available in the specification table.
Utilisation Category
Category A
This spec is not available in the specification table.
Mounting Support
Backplate
This spec is not available in the specification table.
Mechanical Durability
15000 cycles
This spec is not available in the specification table.
Electrical Durability
6000 cycles 415 V In conforming to IEC 60947-2
This spec is not available in the specification table.
Product Certifications
IEC GOST
This spec is not available in the specification table.
Protection Type
Short time short-circuit protection Overload protection (long time) Instantaneous short-circuit protection
This spec is not available in the specification table.
Upside Connection
Front
This spec is not available in the specification table.
Downside Connection
Front
This spec is not available in the specification table.
Electrical Shock Protection Class
Class II
This spec is not available in the specification table.
Thermal Memory
Yes
This spec is not available in the specification table.
Depth
110 mm
This spec is not available in the specification table.
Earth Leakage Protection (Vigi Add On)
Without
This spec is not available in the specification table.
Compatibility Code
CVS400
This spec is not available in the specification table.
[Ics] Rated Service Breaking Capacity
70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 32 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Contact Position Indicator
Yes
This spec is not available in the specification table.
Connections - Terminals
Screw connection
This spec is not available in the specification table.
Height
255 mm
This spec is not available in the specification table.
[Icu] Breaking Capacity
70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Breaking Capacity Code
N
This spec is not available in the specification table.
Long Time Pick-Up Adjustment Type Ir
Adjustable 9 settings
This spec is not available in the specification table.
Long Time Pick-Up Adjustment Range
160…400 A
This spec is not available in the specification table.
Long Time Delay Adjustment Type
Fixed
This spec is not available in the specification table.
Instantaneous Pick-Up Adjustment Type Ii
Fixed
This spec is not available in the specification table.
Instantaneous Pick-Up Adjustment Range
11 x In
This spec is not available in the specification table.
[Tr] Long-Time Delay Adjustment Range
5.5 s at 7.2 x Ir 8 s at 6 x Ir 200 s at 1.5 x Ir
This spec is not available in the specification table.
Short-Time Pick-Up Adjustment Type Isd
Adjustable 9 settings
This spec is not available in the specification table.
[Isd] Short-Time Pick-Up Adjustment Range
1.5...10 x Ir
This spec is not available in the specification table.
Short-Time Delay Adjustment Type
Fixed
This spec is not available in the specification table.
Deskripsi Produk

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Circuit Breaker dari SCHNEIDER ELECTRIC
Temukan dan bandingkan barang serupa
Lebih Dari Circuit Breaker
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas