Rated Current
28.5 A at <= 440 V 23 A at 500 V 21 A at 690 V
Rated Voltage
690 V AC for power circuit
Operating Temperature
-25…60 °C with LUCM -25…70 °C with LUCA, LUCB, LUCC, LUCD
Standards and Certifications
EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
Coil Voltage
110...240 V AC 50/60 Hz 110...220 V DC
Auxiliary Contacts
1 NO + 1 NC
Width
45 mm
Depth
126 mm
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-6-2 (pollution degree 3) 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-6-2
Ip Degree Of Protection
IP20 conforming to IEC 60947-1 (front panel and wired terminals) IP20 conforming to IEC 60947-1 (other faces) IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Height
224 mm
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys Ultra
This spec is not available in the specification table.
Device Short Name
LU2B
This spec is not available in the specification table.
Device Application
Motor control Motor protection
This spec is not available in the specification table.
Pole Configuration
3P
This spec is not available in the specification table.
Utilisation Category
AC-43 AC-44 AC-41
This spec is not available in the specification table.
Compatibility Code
LU2B
This spec is not available in the specification table.
Network Frequency
40...60 Hz
This spec is not available in the specification table.
Suitability For Isolation
Yes
This spec is not available in the specification table.
[Ics] Rated Service Breaking Capacity
50 kA at 230 V 50 kA at 440 V 10 kA at 500 V 4 kA at 690 V
This spec is not available in the specification table.
Connections - Terminals
Control circuit: screw clamp terminals 1 cable(s) 0.34…1.5 mm² flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 0.75…1.5 mm² rigid Control circuit: screw clamp terminals 2 cable(s) 0.34…1.5 mm² flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 0.75…1.5 mm² rigid Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end
This spec is not available in the specification table.
Mechanical Durability
15 Mcycles
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
2000 m
This spec is not available in the specification table.
Tightening Torque
Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
This spec is not available in the specification table.
Fixing Mode
Clipped (DIN rail) Screw-fixed (plate)
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
32 A
This spec is not available in the specification table.
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
This spec is not available in the specification table.
Control Circuit Voltage Limits
55 V DC drop-out 55 V AC drop-out 88...242 V DC in operation 88...264 V AC in operation
This spec is not available in the specification table.
Heat Dissipation
3 W for control circuit with LUCA, LUCB, LUCC, LUCD 1.8 W for control circuit with LUCM
This spec is not available in the specification table.
Operating Time
150 ms with change of direction for power circuit 35 ms opening for control circuit 75 ms without change of direction for power circuit 50 ms closing for control circuit
This spec is not available in the specification table.
Maximum Operating Rate
3600 cyc/h
This spec is not available in the specification table.
Product Certifications
CE UL CSA CCC EAC ASEFA ATEX Marine
This spec is not available in the specification table.
Protective Treatment
TH conforming to IEC 60068
This spec is not available in the specification table.
Fire Resistance
960 °C parts supporting live components conforming to IEC 60695-2-12 650 °C conforming to IEC 60695-2-12
This spec is not available in the specification table.
Product Compatibility
Control unit LUC.X6FU Control unit LUC.1XFU Control unit LUC.05FU Control unit LUC.12FU Control unit LUC.18FU Control unit LUC.32FU
This spec is not available in the specification table.
Typical Current Consumption
1000 mA at 110...220 V DC I maximum while closing 1000 mA at 110...240 V AC I maximum while closing
This spec is not available in the specification table.
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
This spec is not available in the specification table.
Shock Resistance
10 gn power poles open conforming to IEC 60068-2-27 15 gn power poles closed conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27 4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
This spec is not available in the specification table.
Resistance To Electrostatic Discharge
8 kV level 3 in open air conforming to IEC 61000-4-2 8 kV level 4 on contact conforming to IEC 61000-4-2
This spec is not available in the specification table.
Non-Dissipating Shock Wave
1 kV serial mode conforming to IEC 60947-6-2 2 kV common mode conforming to IEC 60947-6-2
This spec is not available in the specification table.
Resistance To Radiated Fields
10 V/m 3 conforming to IEC 61000-4-3
This spec is not available in the specification table.
Resistance To Fast Transients
2 kV class 3 serial link conforming to IEC 61000-4-4 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
This spec is not available in the specification table.
Immunity To Radioelectric Fields
10 V conforming to IEC 61000-4-6
This spec is not available in the specification table.
Immunity To Microbreaks
3 ms for control circuit
This spec is not available in the specification table.
Immunity To Voltage Dips
70 % / 500 ms conforming to IEC 61000-4-11
This spec is not available in the specification table.
Inrush Restraint Duration
25 ms AC 50/60 Hz 15 ms DC
This spec is not available in the specification table.
Deskripsi Produk

Rp 21.032.085
Kuantitas:
EA
This item is sold by
Image
Schneider Electric
0
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Starter dari SCHNEIDER ELECTRIC
Temukan dan bandingkan barang serupa
Lebih Dari Motor Starter
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas