Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Schneider Electric LC1F630F7 3P (3 Tidak) - Kontaktor Tesys F
Schneider Electric LC1F630F7 3P (3 Tidak) - Kontaktor Tesys F
Image
Image
Specifications
infotip-icon
View other Contactors dimensions or variations
Please select at least one specification below.
Device Short Name
LC1F
Range Of Product
TeSys F
Depth
255 mm
Poles Description
3P
Contactor Application
Resistive load Motor control
Compatibility Code
LC1F
This spec is not available in the specification table.
Standards
IEC 60947-1 JIS C8201-4-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
8 kV
This spec is not available in the specification table.
Mounting Support
Plate
This spec is not available in the specification table.
Connections - Terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm Power circuit: bolted connection
This spec is not available in the specification table.
Height
304 mm
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
This spec is not available in the specification table.
Ambient Air Temperature For Operation
-5…55 °C
This spec is not available in the specification table.
Mechanical Durability
5 Mcycles
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-60…80 °C
This spec is not available in the specification table.
Operating Altitude
3000 m without derating
This spec is not available in the specification table.
Tightening Torque
Control circuit: 1.2 N.m Power circuit: 58 N.m
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
This spec is not available in the specification table.
[Ie] Rated Operational Current
1000 A (at <40 °C) at <= 440 V AC AC-1 630 A (at <55 °C) at <= 440 V AC AC-3
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
110 V AC 40...400 Hz
This spec is not available in the specification table.
Inrush power in VA
1650 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
This spec is not available in the specification table.
Hold-in power consumption in VA
22 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
This spec is not available in the specification table.
Heat dissipation
20 W
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Utilisation Category
AC-4 AC-1 AC-3
This spec is not available in the specification table.
Motor Power Kw
335 kW at 380...400 V AC 50/60 Hz (AC-3) 375 kW at 415 V AC 50/60 Hz (AC-3) 400 kW at 440 V AC 50/60 Hz (AC-3) 400 kW at 500 V AC 50/60 Hz (AC-3) 450 kW at 660...690 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 220...230 V AC 50/60 Hz (AC-3) 100 kW at 400 V AC 50/60 Hz (AC-4)
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
1000 A (at 40 °C) 1250 A
This spec is not available in the specification table.
Rated Breaking Capacity
5040 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
[Icw] Rated Short-Time Withstand Current
5050 A 40 °C - 10 s 4400 A 40 °C - 30 s 3400 A 40 °C - 1 min 2200 A 40 °C - 3 min 1600 A 40 °C - 10 min
This spec is not available in the specification table.
Associated Fuse Rating
1000 A gG at <= 440 V 630 A aM at <= 440 V
This spec is not available in the specification table.
Average Impedance
0.12 mOhm - Ith 1000 A 50 Hz
This spec is not available in the specification table.
Power Dissipation Per Pole
120 W AC-1 48 W AC-3
This spec is not available in the specification table.
Control Circuit Type
AC at 40...400 Hz
This spec is not available in the specification table.
Control Circuit Voltage Limits
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.25...0.5 Uc 40...400 Hz (at 55 °C)
This spec is not available in the specification table.
Operating Time
40...80 ms closing 100...200 ms opening
This spec is not available in the specification table.
Auxiliary Contact Composition
1200 cyc/h 55 °C
This spec is not available in the specification table.
Protective Treatment
TH
This spec is not available in the specification table.
Permissible Ambient Air Temperature Around The Device
-40…70 °C
This spec is not available in the specification table.
Power Pole Contact Composition
3 NO
This spec is not available in the specification table.
Motor Starter Type
Direct on-line contactor
This spec is not available in the specification table.
Motor Power Range
250…500 kW at 380…440 V 3 phases 110…220 kW at 200…240 V 3 phases 250…500 kW at 480…500 V 3 phases
This spec is not available in the specification table.
Deskripsi Produk

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contactors dari SCHNEIDER ELECTRIC
Temukan dan bandingkan barang serupa
Lebih Dari Contactors
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas