Shopping List
Daftar Belanja
IDR - Rp
Image
/
/
/
/
Pemutus Sirkuit Motor Schneider Electric GV3P50, Tesys Deca Frame 3,3P,37-50A, Magnetik Termal, Terminal Everlink
Pemutus Sirkuit Motor Schneider Electric GV3P50, Tesys Deca Frame 3,3P,37-50A, Magnetik Termal, Terminal Everlink
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Motor Protection Circuit Breakers dimensions or variations
Please select at least one specification below.
Poles
3P
Rated Current
50 A
Colour
Dark grey
Trip Unit Technology
Thermal-magnetic
Control Type
Rotary handle
Range
TeSys Deca
[Ui] Rated Insulation Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage
6 kV conforming to IEC 60947-2
IP Degree of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature for Operation
-20…60 °C
Ambient Air Temperature for Storage
-40…80 °C
Operating Altitude
3000 m
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Width
55 mm
This spec is not available in the specification table.
Device Short Name
GV3P
This spec is not available in the specification table.
Product Name
TeSys GV3 TeSys Deca
This spec is not available in the specification table.
Depth
136 mm
This spec is not available in the specification table.
Device Application
Motor protection
This spec is not available in the specification table.
Network Type
AC
This spec is not available in the specification table.
Network Frequency
50/60 Hz conforming to IEC 60947-4-1
This spec is not available in the specification table.
Utilisation Category
AC-3 conforming to IEC 60947-4-1
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to IEC 60947-1
This spec is not available in the specification table.
Standards
EN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
This spec is not available in the specification table.
Height
132 mm
This spec is not available in the specification table.
Mechanical Durability
50000 cycles
This spec is not available in the specification table.
Electrical Durability
50000 cycles for AC-3 at 415 V In
This spec is not available in the specification table.
Tightening Torque
5 N.m - on screw clamp terminal
This spec is not available in the specification table.
Fixing Mode
35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws)
This spec is not available in the specification table.
Motor Power kW
22 kW at 400/415 V AC 50/60 Hz 30 kW at 500 V AC 50/60 Hz 45 kW at 690 V AC 50/60 Hz
This spec is not available in the specification table.
[Ith] conventional free air thermal current
50 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Power dissipation per pole
8 W
This spec is not available in the specification table.
Product certifications
CCC UL CSA EAC ATEX LROS (Lloyds register of shipping) BV ABS DNV-GL UKCA
This spec is not available in the specification table.
Climatic withstand
conforming to IACS E10
This spec is not available in the specification table.
Fire resistance
960 °C conforming to IEC 60695-2-11
This spec is not available in the specification table.
Mechanical robustness
Shocks: 15 Gn for 11 ms contactor open Shocks: 30 Gn for 11 ms contactor closed Vibrations: 4 Gn, 5...300 Hz
This spec is not available in the specification table.
[Ics] rated service short-circuit breaking capacity
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Thermal protection adjustment range
37…50 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Magnetic tripping current
700 A
This spec is not available in the specification table.
Phase failure sensitivity
Yes conforming to IEC 60947-4-1
This spec is not available in the specification table.
Rated duty
Continuous conforming to IEC 60947-4-1
This spec is not available in the specification table.
IK Degree of Protection
IK09 enclosure
This spec is not available in the specification table.
Deskripsi Produk

Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Protection Circuit Breakers dari SCHNEIDER ELECTRIC
Temukan dan bandingkan barang serupa
Lebih Dari Motor Protection Circuit Breakers
Perluas pencarian anda dengan pilihan yang lebih bervariasi
Baru Saja Dilihat Produk
Bandingkan dan Rujuk ke item yang dilihat sebelumnya
Image
Atas