Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Siemens 3RH2911-1GA22 Contact Aux 2NO 2NC
Siemens 3RH2911-1GA22 Contact Aux 2NO 2NC
Image
Image
Technical Data Sheets
Product Description

Siemens 3RH2911-1GA22 Contact Aux 2NO 2NC

Closely monitor a contactor with this auxiliary contact block from Siemens. For ease of monitoring, it sends a signal to a PLC (programmable logic controller) if it detects any status changes. Installation is simple thanks to the snap-on design, which lets you clip it on the front of the main contactor with a secure hold. For long-lasting performance, it has a mechanical service life of 10 million cycles. Install this auxiliary contact block on a control panel to regulate alarm and indication systems.

• Surge voltage resistance of 6kV to withstand current overloads
• Wide operating temperature range of -25°C to +60°C for use in demanding environments
• Compact dimensions of 37.5 (height) x 36 (width) x 43.7mm (depth) for installation in tight spaces
• Contact reliability of one possible incorrect switching operation in 100 million indicates efficiency

RM 49.55
Image
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
57 Items
auxiliary-contact-img
Rated Current
6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC
Range
TeSys D, TransferPacT, C6-, Tesys, Multi 9
Standard
IEC 60947-3, IEC 60947-5, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1, EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14, 500 V, 400 V
IP Degree of Protection
IP2X conforming to IEC 60529, IP20 conforming to IEC 60529, IP2X, IP20 conforming to EN/IEC 60947-5-1, IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Ambient Air Temperature for Operation
-5…60 °C, -20…50 °C, -35…70 °C, -25…50 °C, -25…60 °C
Ambient Air Temperature for Storage
-60…80 °C, -50…70 °C, -40…70 °C, -40…85 °C, -50…80 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from Siemens
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top