Schneider Electric RMNF22TB30 3-phase Control Relay, Harmony Control Relays, 8A, 2CO, Overfrequency and Underfrequency, 208…480V Ac
Schneider Electric RMNF22TB30 3-phase Control Relay, Harmony Control Relays, 8A, 2CO, Overfrequency and Underfrequency, 208…480V Ac
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Control Relays dimensions or variations
Please select at least one specification below.
Utilisation Category
AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1
Standards
IEC 60255-1
[Ui] Rated Insulation Voltage
400 V
Mounting Support
35 mm DIN rail conforming to IEC 60715
Ip Degree Of Protection
IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529
Ambient Air Temperature For Operation
-20…60 °C
Mechanical Durability
10000000 cycles
Ambient Air Temperature For Storage
-40…70 °C
[Ith] Conventional Free Air Thermal Current
8 A
Minimum Switching Current
100 mA at 6 V
Insulation Resistance
> 100 MOhm at 500 V DC conforming to IEC 60255-27
Product Certifications
CE UL CSA CCC EAC RCM
[Uimp] Rated Impulse Withstand Voltage
4 kV during 1.2/50 µs
This spec is not available in the specification table.
Connections - Terminals
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.5...2 x 1.5 mm² (AWG 20...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.5...1 x 2.5 mm² (AWG 20...AWG 14) flexible with cable end
This spec is not available in the specification table.
Tightening Torque
0.6…1 N.m conforming to IEC 60947-1 0.60…0.99 N.m conforming to IEC 60947-1
This spec is not available in the specification table.
Immunity To Microbreaks
10 ms
This spec is not available in the specification table.
Local Signalling
LED Un: (steady), green for power ON LED R1: (steady), amber for relay energised LED R1: (blinking), amber for timing in progress LED R2: (steady), amber for relay energised LED R2: (blinking), amber for timing in progress LED PL: (steady), red for alarm phase failure triggered LED PS: (blinking), red for alarm phase sequence failure triggered LED UV: (steady), red for alarm undervoltage failure triggered LED OV: (blinking), red for alarm overvoltage failure triggered LED UF: (steady), red for alarm underfrequency failure triggered LED OF: (blinking), red for alarm overfrequency failure triggered LED ASYM: (steady), red for alarm asymmentry failure triggered
This spec is not available in the specification table.
Control Type
Without test button
This spec is not available in the specification table.
Range Of Product
Harmony Control Relays
This spec is not available in the specification table.
Housing Material
Self-extinguishing plastic
This spec is not available in the specification table.
Overvoltage Category
III conforming to IEC 60664-1 III conforming to UL 508
This spec is not available in the specification table.
Pollution Degree
3 conforming to IEC 60664-1 3 conforming to UL 508
This spec is not available in the specification table.
Relative Humidity
93…97 % at 25…55 °C conforming to IEC 60068-2-30
This spec is not available in the specification table.
Electrical Durability
100000 cycles
This spec is not available in the specification table.
Contacts Material
Cadmium free
This spec is not available in the specification table.
Electromagnetic Compatibility
Voltage dips and interruptions immunity test - test level: 70 % (25/30 cycles) conforming to IEC 61000-4-11 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Immunity for industrial environments conforming to IEC 61000-6-2 1 MHz damped oscillating wave - test level: 2.5 kV CM, 1 kV DM criteria B conforming to IEC 61000-4-18 Voltage dips and interruptions immunity test - test level: 0 % (0.5...25 cycles) conforming to IEC 61000-4-11 Magnetic field at power frequency - test level: 30 A/m (continuous)-300 A/m (1-3 s) level 4 conforming to IEC 61000-4-8 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 Voltage dips and interruptions immunity test - test level: 40 % (10/12 cycles) conforming to IEC 61000-4-11 Voltage interruptions - test level: 0 % criteria C (250/300 cycles) conforming to IEC 61000-4-29 Electrical fast transient/burst immunity test - test level: 4 kV criteria B (direct) conforming to IEC 61000-4-4 Emission standard for industrial environments conforming to IEC 61000-6-4 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Conducted RF disturbances level 3 conforming to IEC 61000-4-6
This spec is not available in the specification table.
Contacts Type And Composition
2 C/O
This spec is not available in the specification table.
Product Compatibility
NFC enabled mobile device
This spec is not available in the specification table.
Shock Resistance
15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
This spec is not available in the specification table.
Vibration Resistance
0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 1 gn (f= 58.1…150 Hz) not in operation conforming to IEC 60068-2-6 0.035 mm (f= 10…58.1 Hz) in operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
This spec is not available in the specification table.
Supply Voltage Limits
166.4…576 V AC line to line 96…332.4 V AC line to neutral
This spec is not available in the specification table.
Directives
2014/30/EU - electromagnetic compatibility 2014/35/EU - low voltage directive 2014/53/EU - radio equipment directive
This spec is not available in the specification table.
Response Time
<= 300 ms
This spec is not available in the specification table.
Mounting Position
Any position
This spec is not available in the specification table.
Power Consumption In Va
4 VA at 480 V AC 60 Hz
This spec is not available in the specification table.
Maximum Switching Current
8 A AC
This spec is not available in the specification table.
Maximum Switching Voltage
250 V AC
This spec is not available in the specification table.
Time Delay Type
Adjustable 0.1 s...1 min
This spec is not available in the specification table.
Repeat Accuracy
+/- 0.5 % for input circuit +/- 3 % for time delay
This spec is not available in the specification table.
Setting Accuracy Of Time Delay
+/- 3 % for 10 s...60 min time delay range +/- 300 ms for 0...10 s time delay range
This spec is not available in the specification table.
Switching Capacity In Va
2000 VA
This spec is not available in the specification table.
Relay Type
Control relay
This spec is not available in the specification table.
Network Number Of Phases
3 phases
This spec is not available in the specification table.
Relay Name
RMNF22
This spec is not available in the specification table.
Relay Monitored Parameters
Phase sequence Phase failure detection Overvoltage detection Undervoltage detection Overfrequency and underfrequency Asymmetry
This spec is not available in the specification table.
Measurement Range
208...480 V AC
This spec is not available in the specification table.
Reset Time
1500 ms at maximum voltage
This spec is not available in the specification table.
Output Contacts
2 C/O
This spec is not available in the specification table.
Hysteresis
3 % of fixed for phase failure detection
This spec is not available in the specification table.
Maximum Measuring Cycle
150 ms measurement cycle as true rms value
This spec is not available in the specification table.
Measurement Error
< 0.05 %/Hz with frequency variation < 0.05 %/°C with temperature variation
This spec is not available in the specification table.
[Un] Rated Nominal Voltage
208...480 V AC 50/60 Hz, non self-powered 120...277 V AC 50/60 Hz, non self-powered
This spec is not available in the specification table.
Dielectric Test Voltage
2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
This spec is not available in the specification table.
Setting Accuracy Of The Switching Threshold
+/- (1.5 % + 1 V)
This spec is not available in the specification table.
Supply Voltage Frequency
50...60 Hz +/- 10 %
This spec is not available in the specification table.
Run-Up Delay At Power-Up Max
650 ms
This spec is not available in the specification table.
Threshold Adjustment Voltage
2...20 % of Un selected
This spec is not available in the specification table.
Adjustment Of Asymmetry Threshold
2...20 % of Un selected
This spec is not available in the specification table.
Product Description
RM 876.37
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Control Relays
37 Items
control-relays-img
Utilisation Category
DC-13 AC-15 AC-14, AC-14 AC-15 DC-13, AC-14 DC-13 AC-15, AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1, AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1
Standards
EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1, IEC 61984, IEC 60255-6, IEC 60255-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947 690 V conforming to VDE 0110 group C 690 V conforming to BS 5424 690 V conforming to UL 508 690 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947 750 V conforming to VDE 0110 group C 690 V conforming to BS 5424 600 V conforming to CSA C22.2 No 14, 400 V, 250 V conforming to IEC 60664-1, 250 V conforming to IEC 60664-1 400 V conforming to IEC 60664-1
Ip Degree Of Protection
IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529, IP20 conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529 IP30 (housing) conforming to IEC 60529, IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Ambient Air Temperature For Operation
-40…60 °C 60…70 °C with derating, -20…60 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz AC/DC, -25…85 °C, -20…50 °C at 60 Hz -20…60 °C at 50 Hz
Mechanical Durability
20 Mcycles, 30 Mcycles, 10 Mcycles, 10000000 cycles, 30000000 cycles
Ambient Air Temperature For Storage
-50…80 °C, -60…80 °C, -50…70 °C, -40…85 °C, -40…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Control Relays from SCHNEIDER ELECTRIC
Source & compare similar products
More from Control Relays
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top