Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric LV431780 Micrologic 2.2 - Circuit Breaker Compact NSX250F
Schneider Electric LV431780 Micrologic 2.2 - Circuit Breaker Compact NSX250F
Image
Image
Specifications
infotip-icon
View other Molded Case Circuit Breakers - MCCBs dimensions or variations
Please select at least one specification below.
Poles
4
Rated Current
250A
Rated Voltage
690 V AC
This spec is not available in the specification table.
Mounting Type
Fixed
This spec is not available in the specification table.
Standards and Certifications
EN/IEC 60947-2, UL 508
This spec is not available in the specification table.
Breaking Capacity
"85 kA at 240 V AC 50/60 Hz conforming to UL 508, 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2, 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 35 kA at 480 V AC 50/60 Hz conforming to UL 508, 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 15 kA at 600 V AC 50/60 Hz conforming to UL 508"
This spec is not available in the specification table.
Product Description

SCHNEIDER ELECTRIC Circuit Breaker Compact NSX250F - Micrologic 2.2 - 250 a - 4 Poles 4d LV431780

Main features

  • Range : ComPact
  • Product name : ComPact NSX
  • Range of product : ComPact NSX100...250
  • Device short name : NSX250F
  • Product or component type : Circuit breaker
  • Device application : Distribution
  • Poles description : 4P
  • Protected poles description : 3t + N/23t4t
  • Neutral position : Left
  • [In] rated current : 250 A at 40 °C
  • [Ue] rated operational voltage : 690 V AC 50/60 Hz
  • Network type : AC
  • Network frequency : 50/60 Hz
  • Suitability for isolation : Yes conforming to EN/IEC 60947-2
  • Utilisation category : Category A
  • Breaking capacity : 85 kA at 240 V AC 50/60 Hz conforming to UL 50822 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-235 kA at 480 V AC 50/60 Hz conforming to UL 50830 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-215 kA at 600 V AC 50/60 Hz conforming to UL 508
  • Breaking capacity code : F 36 kA 415 V AC
  • Trip unit name : Micrologic 2.2
  • Trip unit technology : Electronic
  • Trip unit protection functions : LSoI
  • Control type : Toggle
  • Mounting mode : Fixed
RM 5,080.86
Image
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Molded Case Circuit Breakers - MCCBs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Molded Case Circuit Breakers - MCCBs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top