This spec is not available in the specification table.
Standards
IEC 60947-1
JIS C8201-4-1
EN 60947-1
IEC 60947-4-1
EN 60947-4-1
This spec is not available in the specification table.
[Ui] Rated Insulation Voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
8 kV
This spec is not available in the specification table.
Mounting Support
Plate
This spec is not available in the specification table.
Connections - Terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mm
Power circuit: bolted connection
This spec is not available in the specification table.
Height
304 mm
This spec is not available in the specification table.
Ip Degree Of Protection
IP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
This spec is not available in the specification table.
Ambient Air Temperature For Operation
-5…55 °C
This spec is not available in the specification table.
Mechanical Durability
5 Mcycles
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-60…80 °C
This spec is not available in the specification table.
Operating Altitude
3000 m without derating
This spec is not available in the specification table.
Tightening Torque
Control circuit: 1.2 N.m
Power circuit: 58 N.m
This spec is not available in the specification table.
[Ue] Rated Operational Voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
This spec is not available in the specification table.
[Ie] Rated Operational Current
1000 A (at <40 °C) at <= 440 V AC AC-1
630 A (at <55 °C) at <= 440 V AC AC-3
This spec is not available in the specification table.
[Uc] Control Circuit Voltage
110 V AC 40...400 Hz
This spec is not available in the specification table.
Inrush power in VA
1650 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
This spec is not available in the specification table.
Hold-in power consumption in VA
22 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
This spec is not available in the specification table.
Heat dissipation
20 W
This spec is not available in the specification table.
Range
TeSys
This spec is not available in the specification table.
Utilisation Category
AC-4
AC-1
AC-3
This spec is not available in the specification table.
Motor Power Kw
335 kW at 380...400 V AC 50/60 Hz (AC-3)
375 kW at 415 V AC 50/60 Hz (AC-3)
400 kW at 440 V AC 50/60 Hz (AC-3)
400 kW at 500 V AC 50/60 Hz (AC-3)
450 kW at 660...690 V AC 50/60 Hz (AC-3)
450 kW at 1000 V AC 50/60 Hz (AC-3)
200 kW at 220...230 V AC 50/60 Hz (AC-3)
100 kW at 400 V AC 50/60 Hz (AC-4)
This spec is not available in the specification table.
[Ith] Conventional Free Air Thermal Current
1000 A (at 40 °C)
1250 A
This spec is not available in the specification table.
Rated Breaking Capacity
5040 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
[Icw] Rated Short-Time Withstand Current
5050 A 40 °C - 10 s
4400 A 40 °C - 30 s
3400 A 40 °C - 1 min
2200 A 40 °C - 3 min
1600 A 40 °C - 10 min
This spec is not available in the specification table.
Associated Fuse Rating
1000 A gG at <= 440 V
630 A aM at <= 440 V
This spec is not available in the specification table.
Average Impedance
0.12 mOhm - Ith 1000 A 50 Hz
This spec is not available in the specification table.
Power Dissipation Per Pole
120 W AC-1
48 W AC-3
This spec is not available in the specification table.
Control Circuit Type
AC at 40...400 Hz
This spec is not available in the specification table.