Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Schneider Electric 1.5 Kw Dol Starter 415V 2.6-3.7A LE1M35N710
Schneider Electric 1.5 Kw Dol Starter 415V 2.6-3.7A LE1M35N710
Image
Image
Product Description

Schneider Electric 1.5 kW DOL Starter 415V 2.6-3.7A LE1M35N710

Features and Benefits.

The starter features a TeSys LC1Kxx contactor, 1 TeSys LR2k thermal relay (depending on model), 1 green "On" button, 1 red "Stop / Reset" button and an indicator light.

D.O.L Starters.

  • LE1, LE2 range: contactor + overload Relay Up to 37 KW.
  • Available in Reversing and Non-reversing starters
  • Conforms to standards IEC 60947-4-1
  • IP 65 degree of protection.
  • Ambient air temperature: operation from -5°C to +40 °C.
  • For supply voltages between 380 and 440 V the Control circuit is pre-wired between phases. For other supply voltages the control circuit must be wired by the customer.
  • Overload relay must be ordered separately except LE1M pre-configured range.
  • Operating positions are the same as contactors.
  • Enclosure is made from - LE2 K and LE D09-D35 in Polycarbonate, LE D40A-D65A in Sheet Steel.

D.O.L. Starters with a fuse disconnecting switch.

  • Direct on-line LE4, LE8 range fuse switch-disconnector + contactor + overload relay Up to 15 kW.
  • Available in Reversing and Non-reversing starters.
  • Conforms to standards IEC 60947-4-1.
  • IP 65 degree of protection.
  • Ambient air temperature: Operation from -5 to +40 C.
  • For supply voltages between 380 and 440 V the Control circuit is pre-wired between phases. For other supply voltages, the control circuit must be wired by the customer.
  • Overload relay must be ordered separately, same as for fuse.
  • Enclosure is made from Polycarbonate.

D.O.L Starters enclosure for thermal magnetic circuit breaker and contactor.

  • LE1GV Enclosure for thermal magnetic circuit breaker + contactor Up to 5.5 kW.
  • Conforms to standards IEC 60947-4-1.
  • IP 55 degree of protection.
  • Enclosure is made from Polycarbonate

Star-delta starters.

  • Star-delta LE3 range contactors + overload relay Up to 30 kW.
  • Conforms to standards IEC 60947-4-1.
  • IP 65 degree of protection.
  • For supply voltages between 380 and 415 V the Control circuit is pre-wired between phases. For other supply voltages, the control circuit must be wired by the customer.
  • Overload relay must be ordered separately.
  • Enclosure is made from Polycarbonate.

Applications.

  • All types of industry.
  • Infrastructure.
  • Buildings.
  • Machines that need (D.O.L Motor starting or motor stopping, Reverse and Non-reverse starting, Simple soft starting.
  • Overload protection with or without an isolating device.
RM 278.74
Quantity:
EA
This item is sold by
Image
SG-6853024335
Shop by Specification Table
You can find items with similar specifications from the table below.
Motor Starter
194 Items
motor-starter-img
Rated Current
6 A, 250 A, 480 A, 790 A, 320 A
Rated Voltage
220 V, 5 V, 208 V ac, 208 → 690 V ac, 240 V
Standards and Certifications
CE, CSA, CSA C22.2 No 14, C-Tick, EAC, EN 61131-2, EN/IEC 60068-2-27, EN/IEC 60068-2-30, EN/IEC 60068-2-6, EN/IEC 61000-4-4, EN/IEC 61000-4-5, EN/IEC 61000-4-6, IEC 60068-2-27, IEC 61131-2, NOM, UL, UL 508, CCC, CE, CSA, UL, RoHS Compliant, ABS, ATEX, BV, CCC, CSA, CSA C22.2 No. 14, C-TICK, DNV, EAC, EN 60947-4-1, EN/IEC 60068, EN/IEC 60068-2-30, EN/IEC 60070-2-11, EN/IEC 60695-2-12, EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 61000-4-5, GL, IACS E10, IEC 60947-4-1, KERI, LROS (Lloyds register of shipping), NOM, RINA, RMRoS, UL, UL 508, UL 94, CSA, UL
Coil Voltage
110...240 V AC 110...220 V DC, 24 V AC, 380 V AC 50/60 Hz, 415 V AC 50/60 Hz, 220 V AC 50/60 Hz
Width
30 mm, 88 mm, 175 mm, 22.5 mm, 144 mm
Depth
146 mm, 135 mm, 165 mm, 114.5 mm, 170 mm
[Uimp] Rated Impulse Withstand Voltage
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1, 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1, 6 kV conforming to IEC 60947-6-2, 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1, 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Starter from SCHNEIDER ELECTRIC
Source & compare similar products
More from Motor Starter
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top