Murr Elektronik 7000-08041-6301000 M8 Female 0° A-cod. With Cable Pur 3x0.25 Bk UL/CSA+drag Ch. 10m
View Brand
Murr Elektronik 7000-08041-6301000 M8 Female 0° A-cod. With Cable Pur 3x0.25 Bk UL/CSA+drag Ch. 10m
Brand:
Murr Elektronik
Model:
7000-08041-6301000
Product Description
Murr 7000-08041-6301000 M8 Female 0° A-cod. With Cable Pur 3x0.25 Bk UL/CSA+drag Ch. 10m
Cable Details
Cable length
: 10 m
Side 1 (Connector)
Tightening torque
: 0.4 Nm
Mounting method
: Inserted, screwed
Coating contact
: Gold plated
Family construction form
: M8
Thread
: M8 x 1
Suitable for corrugated tube (internal Ø)
: 6.5 mm
Cable outlet
: Straight
Coding
: A
Material contact
: Copper alloy
Material
: PUR (Polyurethane)
No. of poles
: 3
Width across flats
: SW9
Degree of protection (EN IEC 60529)
: IP65, IP66K, IP67
Side 2 (Free Cable End)
Stripping length (jacket)
: 20 mm
Family construction form
: Free cable end
Electrical Data | Supply
Operating voltage AC max.
: 50 V
Operating voltage DC max.
: 60 V
Current operating per contact max.
: 4 A
Diagnostics
Status indication LED
: No
Installation | Connection
Stripping length (jacket)
: 20 mm
Mounting set
: M8 x 1
Device Protection | Electrical
Additional condition protection degree
: Inserted, screwed
Pollution Degree
: 3
Rated surge voltage
: 1.5 kV
Material group (IEC 60664-1)
: I
Mechanical Data | Material Data
Coating locking
: Nickeled
Coating of fitting
: Nickel plated
Material gasket
: FKM (Fluorocarbon rubber)
Locking material
: Zinc die-casting
Material screw connection
: Zinc die-casting
Mechanical Data | Mounting Data
Mounting method
: Inserted, screwed, shaking protection
Environmental Characteristics | Climatic
Operating temperature min.
: -30 °C
Operating temperature max.
: 85 °C
Additional condition temperature range
: Depending on cable quality
Important Installation Notes
Strain relief
: Protect connectors from mechanical loads with cable ties.
Bending radius
: Observe the permissible bending radii to maintain IP protection class. Excessive bending could compromise protection.
Conformity
Product standard
: DIN EN 61076-2-104 (M8)
Cable Specifications
Cable identification
: 630
Cable Type
: 3
Jacket Color
: Black
Type of Certificate
: cURus
Cable Structure
Amount of stranding
: 1
Stranding
: 3 wires twisted
Wire arrangement
: Brown, black, blue
Mechanical Data | Cable
Cable weight
: 26.4 g/m
Material jacket
: PUR
Shore hardness jacket
: 90 ± 5 Shore A
Freedom from ingredients (jacket)
: Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Outer diameter (jacket)
: 4.1 mm
Tolerance outer diameter (sheath)
: ± 5 %
Material wire insulation
: PP (Polypropylene)
Amount wires
: 3
Outer diameter insulation
: 1.25 mm
Outer diameter tolerance core insulation
: ± 5 %
Shore hardness wire insulation
: 70 ± 5 Shore D
Ingredient freeness wire insulation
: Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Amount strands (wire)
: 32
Diameter of single wires
: 0.1 mm
Conductor cross-section (wire)
: 0.25 mm²
Material conductor wire
: Stranded copper wire, bare
Conductor type (wire)
: Strand class 6
Electrical Data | Cable
Nominal voltage AC max.
: 300 V
Current load capacity (standard)
: To DIN VDE 0298-4
Current load capacity min. wire
: 4.5 A
Electrical resistance line constant wire
: 79 Ω/km @ 20 °C
AC withstand voltage (wire - wire)
: 2.5 kV @ 60 s
Power frequency withstand voltage (wire - jacket)
: 2.5 kV @ 60 s
Temperature Range | Cable
Min. operating temperature (static)
: -40 °C
Max. operating temperature (fixed)
: 80 °C / 90 °C @ 10,000 h operation
Operating temperature min. (dynamic)
: -25 °C
Operating temperature max. (dynamic)
: 80 °C / 90 °C @ 10,000 h operation
Resistances | Cable
UV resistance
: DIN EN ISO 4892-2 A
Flame resistance
:
UL 1581 § 1090
UL 1581 § 1100 FT2
IEC 60332-2-2
Chemical resistance
: Good, application-related testing
Gasoline resistance
: Good, application-related testing
Oil resistance
: Good, application-related testing | DIN EN 60811-404
Installation | Cable
Bending radius (fixed)
: 5 x Outer diameter
Bending radius (dynamic)
: 10 x Outer diameter
No. of bending cycles (C-track)
: 10 million @ 25 °C
Traversing distance (C-track)
: 10 m @ 25 °C | Horizontal
Travel speed (C-track)
: 3 m/s @ 25 °C
No. of torsion cycles
: 2 million
Torsion stress
: ± 180 °/m
Torsion speed
: 35 cycles/min
RM 163.99
Lead time of 10 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Add to Cart
Add To Shopping List
This item is sold by
SG-7230136864
View Shop
Free delivery
above
SGD
200
spent
in
this
shop
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Ethernet Cable from Murr Elektronik
Source & compare similar products
More from Ethernet Cable
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Top